Sanyo 8.53E+13 Shape the Indoor Side Tubing, Wiring Instructions General precautions on wiring

Page 9

05-423 KHS0971-1271 12/13/05 1:23 PM Page 9

3-5. Shape the Indoor Side Tubing

(1)Arrangement of tubing by direction

a)Right or left tubing

Cut out the corner of the right/left frame with a hacksaw or the like. (Figs. 20 and 21)

b)Right-rear or left-rear tubing

In this case, the corner of the frame need not be cut.

(2)To mount the indoor unit on the rear panel:

Hang the 2 mounting slots of the unit on the upper tabs of the rear panel. (Fig. 22)

3-6. Wiring Instructions

General precautions on wiring

(1)Before wiring, confirm the rated voltage of the unit as shown on its nameplate, then carry out the wiring closely following the wiring diagram.

(2)Provide a power outlet to be used exclusively for each unit, with a power supply disconnect and cir- cuit breaker for overcurrent protection provided in the exclusive line.

(3)To prevent possible hazards due to insulation failure, the unit must be grounded.

(4)Each wiring connection must be done tightly and in accordance with the wiring system diagram. Wrong wiring may cause the unit to misoperate or become damaged.

(5)Do not allow wiring to touch the refrigerant tubing, compressor, or any moving parts of the fan.

(6)Unauthorized changes in the internal wiring can be very dangerous. The manufacturer will accept no responsibility for any damage or misoperation that occurs as a result of such unauthorized changes.

Frame

Left tubing outlet

Fig. 20

Frame

Right tubing outlet

Fig. 21

Fig. 22

9

Image 9
Contents Contents Installation Instructions…In a Ceiling or Wall For safe installation and trouble-free operation, you must…In a Room …In Moist or Uneven LocationsAccessories Supplied with Unit Table Tools Required for Installation not suppliedGeneral Optional Copper Tubing KitAdditional Materials Required for Installation Installation Site SelectionIndoor Unit Front ViewOutdoor Unit Solid base must not coverHole of the bottom plate Trical wiring or conduits are How to Install the Indoor Unit Remove the Rear Panel from the Unit Make a HoleIf Wooden Wall Install the Rear Panel on the WallIf Block, Brick, Concrete or Similar Type Wall Hole DiaHow to replace the grille Remove the Grille to Install the Indoor UnitShape the Indoor Side Tubing Wiring Instructions General precautions on wiringRecommended Wire Length and Diameter Wiring Instructions for Inter-unit Connections How to connect wiring to the terminal For Indoor Unit For Outdoor Unit For solid core wiring or F-cableFor stranded wiring Right-side tubing MountingLeft-side tubing Switching drain hose and drain capDrain hose Drain capTubing and wiring to the out Do not supply power toTo unmount indoor unit Unit or operate it until allWiring Instructions for the Outdoor Unit How to Install the Outdoor UnitTo 0.5 mm Adjust so that the amount of tube Flaring Procedure with a Flare ToolRefrigerant Tubing Use of the Flaring MethodFinishing the Installation Connecting Tubing between Indoor and Outdoor UnitsInsulation of Refrigerant Tubing Tube Dia Tightening TorqueAir Purging Be sure to completely insert Hex wrench beforeAttempting to turn the valve Operation lamp Timer lamp Quiet lamp ION lamp How to Test Run the Air ConditionerPump Down Basic Functions of the Service ValvesRemote Control Unit Installation Position To take out the remote control unit, pull it forwardMounting on a Wall Address Setting of the Remote Control Unit Address Switch