ADC 450428 service manual For Your Safety

Page 3

IMPORTANT

YOU MUST DISCONNECT and LOCKOUT THE ELECTRIC SUPPLY and THE GAS SUPPLY or THE STEAM SUPPLY BEFORE ANY COVERS or GUARDS ARE REMOVED FROM THE MACHINE TOALLOWACCESS FOR CLEANING,ADJUST- ING, INSTALLATION, or TESTING OFANY EQUIPMENT per OSHA (Occupational Safety and Health Administration) STANDARDS.

“Caution: Label all wires prior to disconnection when servicing controls. Wiring errors can cause improper operation.”

«Attention: Lor des opérations d’entretien des commandes étiqueter tous fils avant de les déconnecter. Toute erreur de câblage peut étre une source de danger et de panne.»

CAUTION

DRYERS SHOULD NEVER BE LEFT UNATTENDED WHILE IN OPERATION.

WARNING

CHILDREN SHOULD NOT BEALLOWED TO PLAY ON OR NEAR THE DRYER(S). CHILDREN SHOULD BE SUPERVISED IF NEAR DRYERS IN OPERATION.

FOR YOUR SAFETY

DO NOT DRY MOP HEADS IN THE DRYER.

DO NOT USE DRYER IN THE PRESENCE OF DRY CLEANING FUMES.

WARNING

UNDER NO CIRCUMSTANCES should the door switch or the heat circuit devices ever be disabled.

Image 3
Contents American Dryer Corporation ML-130Retain This Manual In a Safe Place For Future Reference For Your Safety Page Table of Content Phase 6 OPL System Diagnostics Important Information Safety PrecautionsStandards Routine Maintenance CleaningMATERIALS, GASOLINE, and Their Flammable Vapors Lubrication AdjustmentsInstallation Requirements ENCLOSURE, AIR SUPPLY, and Exhaust RequirementsElectrical and GAS Requirements Operational Service Check Procedure Page HSI HOT Surface Ignition Module Gas Models Only Description of PartsControl BOX Drive MotorGAS Burner Assembly Idler AssemblyBlower Motor and Impellor Main Door Switch Tumbler Basket Bearing and Pulley ArrangementTumbler Basket Sail Switch Gas and Electric Models Only Manual Reset ThermostatHI-LIMIT Gas and Electric Models Only Lint Drawer Switch Lint DrawerSteam Damper System To Replace Computer Control Panel ServicingIntroduction Computer ControlsTo Replace Keyboard Touchpad Label Assembly To Replace Microprocessor Temperature Sensor ProbeTo Replace Computer To Remove Hot Surface Ignitor refer to illustration above Ignition ControlsHSI Ignitor Flame Sensor Probe To Remove Flame Sensor ProbeTo Replace Main Burner Orifices To Test and Adjust Gas Water Column PressureTo Convert from Natural Gas to L.P. Gas To Replace Burner Tubes To Replace HSI Hot Surface Ignition ModuleThermostats Page Personal Injury or Fire could Result Sail Switch Assembly Gas and Electric Models OnlyTo Replace Sail Switch To Adjust Sail SwitchTo Install New Main Door Glass To Replace Main Door AssemblyTo Replace Main Door Hinge Block To Replace Front PanelPulleys To Replace Tumbler Basket PulleyTo Replace Small Idler Pulley To Replace Motor Pulley To Replace Large Idler PulleyTumbler Basket Alignment Vertical Up and Down Adjustment Tumbler Basket AssemblyTo Replace Tumbler Basket or Tumbler Basket Support Tumbler Basket Alignment Lateral Side to Side AdjustmentTo Replace Front Tumbler Basket Support Pillow Block Bearing To Replace Rear Idler Shaft Pillow Block Bearing To Replace Front Idler Shaft Pillow Block BearingTo Replace V-Belts Belt Tension Adjustment Tumbler Basket to IdlerBelt Tension Adjustment Motor to Idler BeltsMotors To Replace Drive MotorTo Replace Impellor Motor Fan Shaft Drive Lint Drawer Assembly To Replace Lint Screen To Replace Lint Drawer SwitchImpellor Troubleshooting No display on computerComputer will not accept keyboard touchpad entries Dryer operates but is taking too long to dry Dryer will not start, but computer display indicators are onBurner hi-limit safety thermostat is tripping Thermal overload for drive motor is trippingOverload for impellor fan motor is tripping There is excessive vibration coming from the tumbler basket Diagnostic L.E.D. light emitting diode Display Failure Codes Phase 6 OPL System DiagnosticsPage E.D. Display Indicator Number E.D. light emitting diode Display IndicatorsE.D. Display Indicator Number FAN Blower Output L.E.D. Indicator AIR AIR JET Output L.E.D. Indicator OptionalHT1 Heat Output L.E.D. Indicator Fuse Main Fuse Input L.E.D. Indicator Lint Lint Door Input L.E.D. IndicatorMain Main Door Input L.E.D. Indicator Power Supply Input L.E.D. Indicator Flame bURNER Control Fail Input L.E.D. IndicatorALL REV E.D. Codes 1. Display CodesGAS Models only Power 24 VAC is not Evident AT GAS Valve GAS/ELECTRIC only BURNER/OVEN Open HI-LIMIT CircuitGAS only Ignition Attempt Failure Computer Logic and Wiring Diagram Page Drive motor reverses but does not forward, blower motor runs No Display ConditionLint Door Condition Blower motor does not operate, drive motor runsMicroprocessor Computer Main Door ConditionFor Phase 6 Models Manual Reset HI-LIMIT InstructionsMotor Plate High and LOW Voltage Technical InformationInformation on the Data Label Data LabelHOW to USE a Manometer Tool List ADC450428 1- 02/22/00-25