SECTION VII
PHASE 6 OPL SYSTEM DIAGNOSTICS
IMPORTANT: YOU MUST DISCONNECT and LOCKOUT THE ELECTRIC SUPPLY and THE GAS SUPPLY or THE STEAM SUPPLY BEFORE ANY COVERS or
GUARDS ARE REMOVED FROM THE MACHINE TO ALLOW ACCESS FOR CLEANING,ADJUSTING, INSTALLATION, or TESTING OFANY EQUIPMENT per OSHA(Occupational Safety and HealthAdministration)
STANDARDS.
ALL major circuits, including door, microprocessor temperature sensor, heat and motor circuits are monitored. The Phase 6 OPL microprocessor controller (computer) will inform the user, via the L.E.D. (light emitting diode) display of certain failure codes, along with indicators both in L.E.D. display and at the output of each relay (and door switch circuit) to easily identify failures.
A. DIAGNOSTIC (L.E.D. [light emitting diode] DISPLAY) FAILURE CODES
1.SAIL SWITCH FAIL- This routine will prevent start up on the machine unless the sail switch is in the correct position. If the sail switch is closed prior to start up the display will read “SAIL SWITCH FAIL” along with an audio indication.
2.No AIRFLOW- If the sail switch opens during cycle operation the display will read “No AIRFLOW” along with an audio indication. The machine will continue to run with no heat for three (3) minutes or until the temperature drops below 100º F (38º C). Upon failure the machine will shut down and display “No AIRFLOW” with an audio indication.
3.bURNER SAFETY FAIL- Routine monitors the temperature above the burner. If the burner
4.dRUM SAFETY FAIL- This routine monitors the tumbler (basket) temperature if the tumbler (basket)
5.No HEAT- This routine monitors the burner ignition. If the burner
IMPORTANT: For other countries, such as Australia, the retry count may not apply due to local approvals.
39