ADC 450428 service manual E.D. Codes 1. Display Codes, All Rev

Page 50

D.L.E.D. CODES 1. Display Codes

A

ALL REV

ANTI WRINKL dELAY TIME ANTI WRINKL GUARd ACTIVE ANTI WRINKL GUARd ON TIME AUTO CYCLE

b

bURNER CONTROL FAIL bURNER FLAME FAIL bURNER SAFETY FAIL bUZZ

bUZZ TIME CEL

CHECK MAIN FUSE CLEAN LINT COOL

COOL TIME_M

COOL TEMP_ CYCLEA CYCLEb

CYCLEC

CYCLED

CYCLEE

CYCLEF dONE dRYING dRY LEVEL_ dRY TEMP F_ dRY TIME_M

dRUM SAFETY FAIL ELAPSE TIME_MIN ELECTRIC

F FAR FLASH GAS HOT LINT dOOR

LINT COUNT

_M REMAIN MAIN dOOR

MANUAL CYCLE

MAX ANTI WRINKL GUARd

NFLASH NoAIRFLOW

NoANTI WRINKL GUARd NoBUZZ

NoHEAT

NoREV

No ROTATE SENSOR PROGRAM REAdY

ROTATE SENSOR ACTIVE ROTATE SENSOR FAIL _RPM

SAIL SWITCH FAIL

SELREV SPIN TIME START GUARd

STEAM STOP TIME

TEMP SENSOR FAIL CHECK TEMP SENSOR FUSE

SLOPE FACTOR ALWAYS REVERSING ANTI-WRINKLE DELAY TIME

ANTI-WRINKLE PROGRAM ACTIVE

ANTI-WRINKLE GUARD ON TIME AUTOMATIC MODE

HEAT LOSS (OFF SET) FACTOR

GAS ONLY POWER (24 VAC) IS NOT EVIDENTAT GAS VALVE NO BURNER FLAME SENSED

GAS/ELECTRIC ONLY BURNER/OVEN OPEN HI-LIMIT CIRCUIT BUZZER (TONE)

BUZ TIME

DEGREE IN CELSIUS

MAIN FUSE FAILURE

PROMPT TO CLEAN LINT SCREEN, DRYER CYCLE LOCKOUT COOL DOWN CYCLE IN PROGRESS

COOL DOWN TIME

COOL DOWN TEMPERATURE

PREPROGRAMMED CYCLE A

PREPROGRAMMED CYCLE B

PREPROGRAMMED CYCLE C

PREPROGRAMMED CYCLE D

PREPROGRAMMED CYCLE E

PREPROGRAMMED CYCLE F

DRYING or COOLING CYCLE COMPLETE or DRYER INANTI-WRINKLE MODE DRYINGCYCLEINPROGRESS

DRYNESS LEVEL(PERCENTAGE OF EXTRACTION) (NUMERICALVALUE) DRYING TEMPERATURE

LENGTH OF DRYING CYCLE TUMBLER HI-LIMIT CIRCUIT IS OPEN CYCLE DISPLAY TIME

SPECIFIC HEAT TYPE or DRYER ELECTRICALLY HEATED FABRIC TEMPERATURE

DEGREE IN FAHRENHEIT

FLASHDISPLAYACTIVE

SPECIFIC HEAT TYPE OF DRYER GAS HEATED INDICATESAN OVERHEAT CONDITION

LINT DRAWER/DOOR CIRCUIT IS OPEN OR FAULT IN THE A.C. SWITCH CIRCUIT DRYING CYCLES RANGE FROM 1-10 CYCLES BEFORE CLEAN LINT DISPLAY CYCLE DISPLAY TIME

DOOR CIRCUIT IS OPEN or FAULT IN THE A.C. DOOR SWITCH CIRCUIT MANUAL MODE

MAXIMUM GUARD TIME FLASH DISPLAY NOT ACTIVE SAIL SWITCH OPEN

ANTI-WRINKLE PROGRAM IS NOT ACTIVE NO BUZZER (TONE)

GAS ONLY IGNITION ATTEMPT FAILURE NO REVERSE

NO ROTATIONAL SENSOR SELECTED PROGRAM MODE

NO CYCLE IN PROGRESS ROTATIONAL SENSOR SELECTED ROTATIONAL SENSOR CIRCUIT FAILURE

MONITORS TUMBLER RPM WITH ROTATIONAL SENSOR CIRCUIT ACTIVE GAS/ELECTRIC ONLY ATTEMPT MADE TO START DRYER WITH SAIL SWITCH DISABLED IN CLOSED POSITION

SELECT REVERSE SPIN TIME

START ANTI-WRINKLE GUARD CYCLE SPECIFIC HEAT TYPE or DRYER STEAM HEATED STOP TIME

FAULT IN M.P. HEAT SENSING CIRCUIT

46

Image 50
Contents ML-130 American Dryer CorporationRetain This Manual In a Safe Place For Future Reference For Your Safety Page Table of Content Phase 6 OPL System Diagnostics Safety Precautions Important InformationStandards MATERIALS, GASOLINE, and Their Flammable Vapors Routine MaintenanceCleaning Adjustments LubricationElectrical and GAS Requirements Installation RequirementsENCLOSURE, AIR SUPPLY, and Exhaust Requirements Operational Service Check Procedure Page Drive Motor Description of PartsControl BOX HSI HOT Surface Ignition Module Gas Models OnlyBlower Motor and Impellor GAS Burner AssemblyIdler Assembly Tumbler Basket Main Door SwitchTumbler Basket Bearing and Pulley Arrangement HI-LIMIT Gas and Electric Models Only Sail Switch Gas and Electric Models OnlyManual Reset Thermostat Steam Damper System Lint Drawer SwitchLint Drawer Computer Controls ServicingIntroduction To Replace Computer Control PanelTo Replace Computer To Replace Keyboard Touchpad Label AssemblyTo Replace Microprocessor Temperature Sensor Probe Ignition Controls To Remove Hot Surface Ignitor refer to illustration aboveTo Remove Flame Sensor Probe HSI Ignitor Flame Sensor ProbeTo Test and Adjust Gas Water Column Pressure To Replace Main Burner OrificesTo Convert from Natural Gas to L.P. Gas Thermostats To Replace Burner TubesTo Replace HSI Hot Surface Ignition Module Page To Adjust Sail Switch Sail Switch Assembly Gas and Electric Models OnlyTo Replace Sail Switch Personal Injury or Fire could ResultTo Replace Main Door Assembly To Install New Main Door GlassTo Replace Front Panel To Replace Main Door Hinge BlockTo Replace Small Idler Pulley PulleysTo Replace Tumbler Basket Pulley To Replace Large Idler Pulley To Replace Motor PulleyTumbler Basket Assembly Tumbler Basket Alignment Vertical Up and Down AdjustmentTumbler Basket Alignment Lateral Side to Side Adjustment To Replace Tumbler Basket or Tumbler Basket SupportTo Replace Front Tumbler Basket Support Pillow Block Bearing To Replace Front Idler Shaft Pillow Block Bearing To Replace Rear Idler Shaft Pillow Block BearingBelts Belt Tension Adjustment Tumbler Basket to IdlerBelt Tension Adjustment Motor to Idler To Replace V-BeltsTo Replace Impellor Motor Fan Shaft Drive MotorsTo Replace Drive Motor Impellor Lint Drawer Assembly To Replace Lint ScreenTo Replace Lint Drawer Switch Computer will not accept keyboard touchpad entries TroubleshootingNo display on computer Dryer will not start, but computer display indicators are on Dryer operates but is taking too long to dryOverload for impellor fan motor is tripping Burner hi-limit safety thermostat is trippingThermal overload for drive motor is tripping There is excessive vibration coming from the tumbler basket Phase 6 OPL System Diagnostics Diagnostic L.E.D. light emitting diode Display Failure CodesPage E.D. light emitting diode Display Indicators E.D. Display Indicator NumberE.D. Display Indicator Number HT1 Heat Output L.E.D. Indicator FAN Blower Output L.E.D. IndicatorAIR AIR JET Output L.E.D. Indicator Optional Main Main Door Input L.E.D. Indicator Fuse Main Fuse Input L.E.D. IndicatorLint Lint Door Input L.E.D. Indicator Flame bURNER Control Fail Input L.E.D. Indicator Power Supply Input L.E.D. IndicatorE.D. Codes 1. Display Codes ALL REVGAS only Ignition Attempt Failure GAS Models only Power 24 VAC is not Evident AT GAS ValveGAS/ELECTRIC only BURNER/OVEN Open HI-LIMIT Circuit Computer Logic and Wiring Diagram Page No Display Condition Drive motor reverses but does not forward, blower motor runsBlower motor does not operate, drive motor runs Lint Door ConditionMain Door Condition Microprocessor ComputerManual Reset HI-LIMIT Instructions For Phase 6 ModelsTechnical Information Motor Plate High and LOW VoltageData Label Information on the Data LabelHOW to USE a Manometer Tool List ADC450428 1- 02/22/00-25