c.If no voltage is present at J7
d.If no voltage is present at J7
6.Main Door Condition
NOTE: Make sure main door and lint door are closed. Also, if checking either switch, the plunger must be depressed.
a.Check L.E.D. (light emitting diode) input light “MAIN” on the component side of the computer. If the light is on, replace the computer.
b.Check voltage (24 VAC) from J7
c.If no voltage is present at J7
7.“No Heat” drive and blower motors run, display reads normal (gas models).
a.Check L.E.D. (light emitting diode) input light “HT1” on the component side of the computer. If the light is on replace the board.
b.If the L.E.D. (light emitting diode) input light “HT1” on the component side of the computer is on and there is no voltage to the HSI (Hot Surface Ignition) module “w” the display will read “BURNER CONTROL FAIL.” The problem is faulty wires or terminations between microprocessor and HSI (Hot Surface Ignition) module.
c.If voltage is present on the HSI (Hot Surface Ignition) module “w” to ground. Check voltage at the gas valve if voltage is present across the two (2) “yellow” wires at the gas valve and the gas supply is on then the fault is that of the gas valve.
8.Microprocessor (Computer)
a.Replace the temperature sensor underneath the tumbler (basket) on a bracket (the bullet shaped device).
b.If it still reads “TEMP SENSOR FAIL CHECK TEMP SENSOR FUSE,” unplug J3
If there is no continuity, check for break in wire, a short to the ground, loose terminations, or even replace the wire.
If there is continuity, computer board is faulty.