ADC 450428 service manual GAS Models only Power 24 VAC is not Evident AT GAS Valve

Page 51

2. Fault Codes

bURNER CONTROL FAIL

- GAS MODELS ONLY POWER (24 VAC) IS NOT EVIDENT AT GAS VALVE

bURNER FLAME FAIL

-The Phase 6 Microprocessor Controller (Computer) DOES NOT SENSE FLAME VERIFICATION (GAS MODEL ONLY)

bURNER SAFETY FAIL

- GAS/ELECTRIC ONLY BURNER/OVEN OPEN HI-LIMIT CIRCUIT

dRUM SAFETY FAIL

- Fault in the TUMBLER (BASKET) HI-LIMIT CIRCUIT

HOT

- Indicates an OVERHEAT CONDITION

LINT dOOR

-When the LINT DOOR OR DRAWER is open or there is a fault in the LINT DOOR/DRAWER CIRCUIT

MAIN dOOR

- When the MAIN DOOR is open or there is a fault in the DOOR CIRCUIT

No AIRFLOW

- Fault in the SAIL SWITCH CIRCUIT (GAS/ELECTRIC MODELS ONLY)

No HEAT

- GAS ONLY IGNITION ATTEMPT FAILURE

ROTATE SENSOR FAIL

- Fault in the ROTATION SENSOR CIRCUIT

SAIL SWITCH FAIL

- Fault in the SAIL SWITCH CIRCUIT (GAS/ELECTRIC MODELS ONLY)

TEMP SENSOR CHECK TEMP SENSOR FUSE

- Fault in the MICROPROCESSOR TEMPERATURE SENSOR CIRCUIT

47

Image 51
Contents American Dryer Corporation ML-130Retain This Manual In a Safe Place For Future Reference For Your Safety Page Table of Content Phase 6 OPL System Diagnostics Important Information Safety PrecautionsStandards Routine Maintenance CleaningMATERIALS, GASOLINE, and Their Flammable Vapors Lubrication AdjustmentsInstallation Requirements ENCLOSURE, AIR SUPPLY, and Exhaust RequirementsElectrical and GAS Requirements Operational Service Check Procedure Page HSI HOT Surface Ignition Module Gas Models Only Description of PartsControl BOX Drive MotorGAS Burner Assembly Idler AssemblyBlower Motor and Impellor Main Door Switch Tumbler Basket Bearing and Pulley ArrangementTumbler Basket Sail Switch Gas and Electric Models Only Manual Reset ThermostatHI-LIMIT Gas and Electric Models Only Lint Drawer Switch Lint DrawerSteam Damper System To Replace Computer Control Panel ServicingIntroduction Computer ControlsTo Replace Keyboard Touchpad Label Assembly To Replace Microprocessor Temperature Sensor ProbeTo Replace Computer To Remove Hot Surface Ignitor refer to illustration above Ignition ControlsHSI Ignitor Flame Sensor Probe To Remove Flame Sensor ProbeTo Replace Main Burner Orifices To Test and Adjust Gas Water Column PressureTo Convert from Natural Gas to L.P. Gas To Replace Burner Tubes To Replace HSI Hot Surface Ignition ModuleThermostats Page Personal Injury or Fire could Result Sail Switch Assembly Gas and Electric Models OnlyTo Replace Sail Switch To Adjust Sail SwitchTo Install New Main Door Glass To Replace Main Door AssemblyTo Replace Main Door Hinge Block To Replace Front PanelPulleys To Replace Tumbler Basket PulleyTo Replace Small Idler Pulley To Replace Motor Pulley To Replace Large Idler PulleyTumbler Basket Alignment Vertical Up and Down Adjustment Tumbler Basket AssemblyTo Replace Tumbler Basket or Tumbler Basket Support Tumbler Basket Alignment Lateral Side to Side AdjustmentTo Replace Front Tumbler Basket Support Pillow Block Bearing To Replace Rear Idler Shaft Pillow Block Bearing To Replace Front Idler Shaft Pillow Block BearingTo Replace V-Belts Belt Tension Adjustment Tumbler Basket to IdlerBelt Tension Adjustment Motor to Idler BeltsMotors To Replace Drive MotorTo Replace Impellor Motor Fan Shaft Drive Lint Drawer Assembly To Replace Lint Screen To Replace Lint Drawer SwitchImpellor Troubleshooting No display on computerComputer will not accept keyboard touchpad entries Dryer operates but is taking too long to dry Dryer will not start, but computer display indicators are onBurner hi-limit safety thermostat is tripping Thermal overload for drive motor is trippingOverload for impellor fan motor is tripping There is excessive vibration coming from the tumbler basket Diagnostic L.E.D. light emitting diode Display Failure Codes Phase 6 OPL System DiagnosticsPage E.D. Display Indicator Number E.D. light emitting diode Display IndicatorsE.D. Display Indicator Number FAN Blower Output L.E.D. Indicator AIR AIR JET Output L.E.D. Indicator OptionalHT1 Heat Output L.E.D. Indicator Fuse Main Fuse Input L.E.D. Indicator Lint Lint Door Input L.E.D. IndicatorMain Main Door Input L.E.D. Indicator Power Supply Input L.E.D. Indicator Flame bURNER Control Fail Input L.E.D. IndicatorALL REV E.D. Codes 1. Display CodesGAS Models only Power 24 VAC is not Evident AT GAS Valve GAS/ELECTRIC only BURNER/OVEN Open HI-LIMIT CircuitGAS only Ignition Attempt Failure Computer Logic and Wiring Diagram Page Drive motor reverses but does not forward, blower motor runs No Display ConditionLint Door Condition Blower motor does not operate, drive motor runsMicroprocessor Computer Main Door ConditionFor Phase 6 Models Manual Reset HI-LIMIT InstructionsMotor Plate High and LOW Voltage Technical InformationInformation on the Data Label Data LabelHOW to USE a Manometer Tool List ADC450428 1- 02/22/00-25