2. Fault Codes
bURNER CONTROL FAIL
- GAS MODELS ONLY POWER (24 VAC) IS NOT EVIDENT AT GAS VALVE
bURNER FLAME FAIL
-The Phase 6 Microprocessor Controller (Computer) DOES NOT SENSE FLAME VERIFICATION (GAS MODEL ONLY)
bURNER SAFETY FAIL
- GAS/ELECTRIC ONLY BURNER/OVEN OPEN HI-LIMIT CIRCUIT
dRUM SAFETY FAIL
- Fault in the TUMBLER (BASKET)
HOT
- Indicates an OVERHEAT CONDITION
LINT dOOR
-When the LINT DOOR OR DRAWER is open or there is a fault in the LINT DOOR/DRAWER CIRCUIT
MAIN dOOR
- When the MAIN DOOR is open or there is a fault in the DOOR CIRCUIT
No AIRFLOW
- Fault in the SAIL SWITCH CIRCUIT (GAS/ELECTRIC MODELS ONLY)
No HEAT
- GAS ONLY IGNITION ATTEMPT FAILURE
ROTATE SENSOR FAIL
- Fault in the ROTATION SENSOR CIRCUIT
SAIL SWITCH FAIL
- Fault in the SAIL SWITCH CIRCUIT (GAS/ELECTRIC MODELS ONLY)
TEMP SENSOR CHECK TEMP SENSOR FUSE
- Fault in the MICROPROCESSOR TEMPERATURE SENSOR CIRCUIT
47