ADC 450428 To Replace Main Burner Orifices, To Test and Adjust Gas Water Column Pressure

Page 23

NOTE: Identify location of each wire for correct reinstallation.

4.Break union connection before gas valve.

5.Loosen and remove four (4) screws securing pipe brackets to burner.

6.Remove gas valve and manifold assembly from dryer.

7.Remove valve mounting bracket, manifold, and piping from gas valve.

8.Reverse procedure for installing new gas valve.

WARNING: Test ALL connections for leaks by brushing on a soapy water solution.

WARNING: NEVER TEST FOR LEAKS WITH A FLAME!!!

To Replace Main Burner Orifices

1.Refer to “To Replace Gas Valve” and follow Step #1 through Step #6.

2.Unscrew main burner orifices and replace.

NOTE: Use extreme care when removing and replacing orifices. These orifices are made of brass and are easily damaged.

3. Reversing the removal procedure for reinstalling.

WARNING: Test ALL connections for leaks by brushing on a soapy water solution.

WARNING: NEVER TEST FOR LEAKS WITH A FLAME!!!

To Test and Adjust Gas (Water Column) Pressure

There are two (2) types of devices commonly used to measure water column pressure. They are spring and mechanical-type gauges and manometers. The spring and mechanical-type gauge is not recommended, because it is easily damaged and not always accurate. A manometer is simply a glass or transparent plastic tube with a scale in inches. When filled with water and pressure applied, the water in the tube rises showing the exact water column pressure.

NOTE: Manometers are available from the factory by ordering ADC Part No. 122804.

1.To Test Gas Water Column (W.C.) Pressure:

a.Connect water column test gauge connection to gas valve pressure tap (1/8” NPT). This pressure tap is located on the outlet (manifold) side of the valve.

b.Start dryer. With burner on, the correct water column reading in inches would be:

Natural Gas - 3.5 Inches Water Column (8.7 mb). L.P. Gas - 10.5 Inches Water Column (26.1 mb).

19

Image 23
Contents American Dryer Corporation ML-130Retain This Manual In a Safe Place For Future Reference For Your Safety Page Table of Content Phase 6 OPL System Diagnostics Important Information Safety PrecautionsStandards MATERIALS, GASOLINE, and Their Flammable Vapors Routine MaintenanceCleaning Lubrication AdjustmentsElectrical and GAS Requirements Installation RequirementsENCLOSURE, AIR SUPPLY, and Exhaust Requirements Operational Service Check Procedure Page HSI HOT Surface Ignition Module Gas Models Only Description of PartsControl BOX Drive MotorBlower Motor and Impellor GAS Burner AssemblyIdler Assembly Tumbler Basket Main Door SwitchTumbler Basket Bearing and Pulley Arrangement HI-LIMIT Gas and Electric Models Only Sail Switch Gas and Electric Models OnlyManual Reset Thermostat Steam Damper System Lint Drawer SwitchLint Drawer To Replace Computer Control Panel ServicingIntroduction Computer ControlsTo Replace Computer To Replace Keyboard Touchpad Label AssemblyTo Replace Microprocessor Temperature Sensor Probe To Remove Hot Surface Ignitor refer to illustration above Ignition ControlsHSI Ignitor Flame Sensor Probe To Remove Flame Sensor ProbeTo Replace Main Burner Orifices To Test and Adjust Gas Water Column PressureTo Convert from Natural Gas to L.P. Gas Thermostats To Replace Burner TubesTo Replace HSI Hot Surface Ignition Module Page Personal Injury or Fire could Result Sail Switch Assembly Gas and Electric Models OnlyTo Replace Sail Switch To Adjust Sail SwitchTo Install New Main Door Glass To Replace Main Door AssemblyTo Replace Main Door Hinge Block To Replace Front PanelTo Replace Small Idler Pulley PulleysTo Replace Tumbler Basket Pulley To Replace Motor Pulley To Replace Large Idler PulleyTumbler Basket Alignment Vertical Up and Down Adjustment Tumbler Basket AssemblyTo Replace Tumbler Basket or Tumbler Basket Support Tumbler Basket Alignment Lateral Side to Side AdjustmentTo Replace Front Tumbler Basket Support Pillow Block Bearing To Replace Rear Idler Shaft Pillow Block Bearing To Replace Front Idler Shaft Pillow Block BearingTo Replace V-Belts Belt Tension Adjustment Tumbler Basket to IdlerBelt Tension Adjustment Motor to Idler BeltsTo Replace Impellor Motor Fan Shaft Drive MotorsTo Replace Drive Motor Impellor Lint Drawer Assembly To Replace Lint ScreenTo Replace Lint Drawer Switch Computer will not accept keyboard touchpad entries TroubleshootingNo display on computer Dryer operates but is taking too long to dry Dryer will not start, but computer display indicators are onOverload for impellor fan motor is tripping Burner hi-limit safety thermostat is trippingThermal overload for drive motor is tripping There is excessive vibration coming from the tumbler basket Diagnostic L.E.D. light emitting diode Display Failure Codes Phase 6 OPL System DiagnosticsPage E.D. Display Indicator Number E.D. light emitting diode Display IndicatorsE.D. Display Indicator Number HT1 Heat Output L.E.D. Indicator FAN Blower Output L.E.D. IndicatorAIR AIR JET Output L.E.D. Indicator Optional Main Main Door Input L.E.D. Indicator Fuse Main Fuse Input L.E.D. IndicatorLint Lint Door Input L.E.D. Indicator Power Supply Input L.E.D. Indicator Flame bURNER Control Fail Input L.E.D. IndicatorALL REV E.D. Codes 1. Display CodesGAS only Ignition Attempt Failure GAS Models only Power 24 VAC is not Evident AT GAS ValveGAS/ELECTRIC only BURNER/OVEN Open HI-LIMIT Circuit Computer Logic and Wiring Diagram Page Drive motor reverses but does not forward, blower motor runs No Display ConditionLint Door Condition Blower motor does not operate, drive motor runsMicroprocessor Computer Main Door ConditionFor Phase 6 Models Manual Reset HI-LIMIT InstructionsMotor Plate High and LOW Voltage Technical InformationInformation on the Data Label Data LabelHOW to USE a Manometer Tool List ADC450428 1- 02/22/00-25