ADC 450428 Fuse Main Fuse Input L.E.D. Indicator, Lint Lint Door Input L.E.D. Indicator

Page 48

6.“FUSE” (MAIN FUSE) Input L.E.D. Indicator

a.Should be on ALL the time (even if the dryer is not running). If the L.E.D. is not on; then the display will read “CHECK MAIN FUSE.” If the main fuse is good then the fault is on the Phase 6 microprocessor controller (computer).

7.“LINT” (LINT DOOR) Input L.E.D. Indicator

a.Should be on ALL the time (unless the lint door is opened then the “LINT” L.E.D. indicator will go out).

b.If the dryer is active (running) and the lint door is opened the “LINT” L.E.D. indicator will go out and the display will read “LINT dOOR.” The dryer will stop until the Lint Drawer has been closed, at which time the L.E.D. display will read “PRESS START.” At this time, to resume the drying cycle press “ENTER/START” key.

8.“MAIN” (MAIN DOOR) Input L.E.D. Indicator

a.Should be on ALL the time (unless the lint door is open or the main door is opened then the “MAIN” L.E.D. indicator will go out).

b.If the dryer is active (running) and the main door is opened the “MAIN” L.E.D. indicator will go out and the display will read “MAIN dOOR.” The dryer will stop until the main door has been closed, at which time the L.E.D. display will read “PRESS START.” At this time, to resume the drying cycle press “ENTER/START” key.

9.“DRUM” (TUMBLER [BASKET] HI-LIMIT) Input L.E.D. Indicator

a.Should be on at ALL times (unless the tumbler [basket] hi-limit switch opens prior during the cycle while the heat was on the display would read “dRUM SAFETY FAIL”). The machine will run with no heat for three (3) minutes or until the temperature drops below 100º F (38º C). Then the machine will shut down still displaying “dRUM SAFETY FAIL” with an audio indication.

10.“SAIL” (SAIL SWITCH) Input L.E.D. Indicator

a.This routine will prevent start up on the machine unless the sail switch is in the correct position. If the sail switch is in the closed position prior to start, the “SAIL” output L.E.D. indicator will be off, the machine will not start and the display will read “SAIL SWITCH FAIL” along with an audio indication.

b.If the sail switch opens during the cycle the “SAIL” output L.E.D. will go out and the display will read “NO AIRFLOW.” The machine will run with no heat for three (3) minutes or until the temperature drops below 100º F (38º C). Then the machine will shut down still displaying “NO AIRFLOW” along with an audio indication.

11.“BURN” (BURN HI-LIMIT) Input L.E.D. Indicator

a.This routine monitors the temperature of the burner. If the burner hi-limit opens during the cycle while the heat was on the “BURN” output L.E.D. indicator goes out and the display reads “bURNER SAFETY FAIL.” The machine will run with no heat for three (3) minutes or until the temperature drops below 100º F (38º C) then the machine will shut down still displaying “bURNER SAFETY FAIL” with an audio indication.

44

Image 48
Contents ML-130 American Dryer CorporationRetain This Manual In a Safe Place For Future Reference For Your Safety Page Table of Content Phase 6 OPL System Diagnostics Safety Precautions Important InformationStandards Routine Maintenance CleaningMATERIALS, GASOLINE, and Their Flammable Vapors Adjustments LubricationInstallation Requirements ENCLOSURE, AIR SUPPLY, and Exhaust RequirementsElectrical and GAS Requirements Operational Service Check Procedure Page Description of Parts Control BOXDrive Motor HSI HOT Surface Ignition Module Gas Models OnlyGAS Burner Assembly Idler AssemblyBlower Motor and Impellor Main Door Switch Tumbler Basket Bearing and Pulley ArrangementTumbler Basket Sail Switch Gas and Electric Models Only Manual Reset ThermostatHI-LIMIT Gas and Electric Models Only Lint Drawer Switch Lint DrawerSteam Damper System Servicing IntroductionComputer Controls To Replace Computer Control PanelTo Replace Keyboard Touchpad Label Assembly To Replace Microprocessor Temperature Sensor ProbeTo Replace Computer Ignition Controls To Remove Hot Surface Ignitor refer to illustration aboveTo Remove Flame Sensor Probe HSI Ignitor Flame Sensor ProbeTo Test and Adjust Gas Water Column Pressure To Replace Main Burner OrificesTo Convert from Natural Gas to L.P. Gas To Replace Burner Tubes To Replace HSI Hot Surface Ignition ModuleThermostats Page Sail Switch Assembly Gas and Electric Models Only To Replace Sail SwitchTo Adjust Sail Switch Personal Injury or Fire could ResultTo Replace Main Door Assembly To Install New Main Door GlassTo Replace Front Panel To Replace Main Door Hinge BlockPulleys To Replace Tumbler Basket PulleyTo Replace Small Idler Pulley To Replace Large Idler Pulley To Replace Motor PulleyTumbler Basket Assembly Tumbler Basket Alignment Vertical Up and Down AdjustmentTumbler Basket Alignment Lateral Side to Side Adjustment To Replace Tumbler Basket or Tumbler Basket SupportTo Replace Front Tumbler Basket Support Pillow Block Bearing To Replace Front Idler Shaft Pillow Block Bearing To Replace Rear Idler Shaft Pillow Block BearingBelt Tension Adjustment Tumbler Basket to Idler Belt Tension Adjustment Motor to IdlerBelts To Replace V-BeltsMotors To Replace Drive MotorTo Replace Impellor Motor Fan Shaft Drive Lint Drawer Assembly To Replace Lint Screen To Replace Lint Drawer SwitchImpellor Troubleshooting No display on computerComputer will not accept keyboard touchpad entries Dryer will not start, but computer display indicators are on Dryer operates but is taking too long to dryBurner hi-limit safety thermostat is tripping Thermal overload for drive motor is trippingOverload for impellor fan motor is tripping There is excessive vibration coming from the tumbler basket Phase 6 OPL System Diagnostics Diagnostic L.E.D. light emitting diode Display Failure CodesPage E.D. light emitting diode Display Indicators E.D. Display Indicator NumberE.D. Display Indicator Number FAN Blower Output L.E.D. Indicator AIR AIR JET Output L.E.D. Indicator OptionalHT1 Heat Output L.E.D. Indicator Fuse Main Fuse Input L.E.D. Indicator Lint Lint Door Input L.E.D. IndicatorMain Main Door Input L.E.D. Indicator Flame bURNER Control Fail Input L.E.D. Indicator Power Supply Input L.E.D. IndicatorE.D. Codes 1. Display Codes ALL REVGAS Models only Power 24 VAC is not Evident AT GAS Valve GAS/ELECTRIC only BURNER/OVEN Open HI-LIMIT CircuitGAS only Ignition Attempt Failure Computer Logic and Wiring Diagram Page No Display Condition Drive motor reverses but does not forward, blower motor runsBlower motor does not operate, drive motor runs Lint Door ConditionMain Door Condition Microprocessor ComputerManual Reset HI-LIMIT Instructions For Phase 6 ModelsTechnical Information Motor Plate High and LOW VoltageData Label Information on the Data LabelHOW to USE a Manometer Tool List ADC450428 1- 02/22/00-25