ADC 450428 service manual Operational Service Check Procedure

Page 12

IMPORTANT: Failure to comply with these codes or ordinances and/or the requirements stipulated in this manual can result in personal injury or component failure.

The gas dryer installation must meet the American National Standard, National Fuel Gas Code ANSI Z223.1- LATEST EDITION, or in Canada, the Canadian Electrical Codes Parts 1 & 2 CSA C22.1-1990 or LATEST EDITION (for Electrical Connections) as well as, local codes and ordinances, and must be done by a qualified technician.

NOTE: Undersized gas piping will result in ignition problems and slow drying and can create a safety hazard.

The dryer must be connected to the type of gas (natural or L.P. [liquid propane]) indicated on the dryer data label. If this information DOES NOT agree with the type of gas available, contact the distributor who sold the dryer or contact the factory.

The gas input ratings shown on the dryer data label are for elevations up to 2,000 feet (610 meters), unless elevation requirements of over 2,000 feet (610 meters) were specified at the time the dryer order was placed with the factory. The adjustment for dryers in the field for elevations over 2,000 feet (610 meters) are made by changing the burner orifices. If this adjustment is necessary, contact the distributor who sold the dryer or contact the factory.

NOTE: Any burner changes must be made by a qualified technician.

C. OPERATIONAL SERVICE CHECK PROCEDURE

1.Turn on electric power to the dryer.

2.To start dryer:

a.Display will read “READY.”

b.Press “E” on the keyboard (touchpad) of microprocessor controller (computer).

c.The dryer will start and the display will show “dr30.”

NOTE: Pressing keyboard (touchpad) selections “A,” “B,” “C,” “D,” and “F” will also start the dryer. Six (6) preprogrammed drying cycles (“A” through “F”) have been stored in the computer’s memory. (Refer to the Computer Operator’s Manual for details.)

3.Make a complete operational check of ALL the operating controls to assure that the timing is correct, temperature selection switches are functioning, etc.

4.Make a complete operational check of ALL safety-related circuits - door switch(es), hi-limit thermostat, sail switch, cycling thermostats, etc.

5.For gas dryers a gas pressure test should be taken at the gas valve pressure tap of each dryer to assure that the water column pressure is correct and consistent.

8

Image 12
Contents ML-130 American Dryer CorporationRetain This Manual In a Safe Place For Future Reference For Your Safety Page Table of Content Phase 6 OPL System Diagnostics Safety Precautions Important InformationStandards Routine Maintenance CleaningMATERIALS, GASOLINE, and Their Flammable Vapors Adjustments LubricationInstallation Requirements ENCLOSURE, AIR SUPPLY, and Exhaust RequirementsElectrical and GAS Requirements Operational Service Check Procedure Page Description of Parts Control BOXDrive Motor HSI HOT Surface Ignition Module Gas Models OnlyGAS Burner Assembly Idler AssemblyBlower Motor and Impellor Main Door Switch Tumbler Basket Bearing and Pulley ArrangementTumbler Basket Sail Switch Gas and Electric Models Only Manual Reset ThermostatHI-LIMIT Gas and Electric Models Only Lint Drawer Switch Lint DrawerSteam Damper System Servicing IntroductionComputer Controls To Replace Computer Control PanelTo Replace Keyboard Touchpad Label Assembly To Replace Microprocessor Temperature Sensor ProbeTo Replace Computer Ignition Controls To Remove Hot Surface Ignitor refer to illustration aboveTo Remove Flame Sensor Probe HSI Ignitor Flame Sensor ProbeTo Test and Adjust Gas Water Column Pressure To Replace Main Burner OrificesTo Convert from Natural Gas to L.P. Gas To Replace Burner Tubes To Replace HSI Hot Surface Ignition ModuleThermostats Page Sail Switch Assembly Gas and Electric Models Only To Replace Sail SwitchTo Adjust Sail Switch Personal Injury or Fire could ResultTo Replace Main Door Assembly To Install New Main Door GlassTo Replace Front Panel To Replace Main Door Hinge BlockPulleys To Replace Tumbler Basket PulleyTo Replace Small Idler Pulley To Replace Large Idler Pulley To Replace Motor PulleyTumbler Basket Assembly Tumbler Basket Alignment Vertical Up and Down AdjustmentTumbler Basket Alignment Lateral Side to Side Adjustment To Replace Tumbler Basket or Tumbler Basket SupportTo Replace Front Tumbler Basket Support Pillow Block Bearing To Replace Front Idler Shaft Pillow Block Bearing To Replace Rear Idler Shaft Pillow Block BearingBelt Tension Adjustment Tumbler Basket to Idler Belt Tension Adjustment Motor to IdlerBelts To Replace V-BeltsMotors To Replace Drive MotorTo Replace Impellor Motor Fan Shaft Drive Lint Drawer Assembly To Replace Lint Screen To Replace Lint Drawer SwitchImpellor Troubleshooting No display on computerComputer will not accept keyboard touchpad entries Dryer will not start, but computer display indicators are on Dryer operates but is taking too long to dryBurner hi-limit safety thermostat is tripping Thermal overload for drive motor is trippingOverload for impellor fan motor is tripping There is excessive vibration coming from the tumbler basket Phase 6 OPL System Diagnostics Diagnostic L.E.D. light emitting diode Display Failure CodesPage E.D. light emitting diode Display Indicators E.D. Display Indicator NumberE.D. Display Indicator Number FAN Blower Output L.E.D. Indicator AIR AIR JET Output L.E.D. Indicator OptionalHT1 Heat Output L.E.D. Indicator Fuse Main Fuse Input L.E.D. Indicator Lint Lint Door Input L.E.D. IndicatorMain Main Door Input L.E.D. Indicator Flame bURNER Control Fail Input L.E.D. Indicator Power Supply Input L.E.D. IndicatorE.D. Codes 1. Display Codes ALL REVGAS Models only Power 24 VAC is not Evident AT GAS Valve GAS/ELECTRIC only BURNER/OVEN Open HI-LIMIT CircuitGAS only Ignition Attempt Failure Computer Logic and Wiring Diagram Page No Display Condition Drive motor reverses but does not forward, blower motor runsBlower motor does not operate, drive motor runs Lint Door ConditionMain Door Condition Microprocessor ComputerManual Reset HI-LIMIT Instructions For Phase 6 ModelsTechnical Information Motor Plate High and LOW VoltageData Label Information on the Data LabelHOW to USE a Manometer Tool List ADC450428 1- 02/22/00-25