1. PRODUCT DESCRIPTION

1.1 Introduction

All versions of the Model 3100 Flame Detector Se- ries utilize Ultraviolet, Infrared and Visible spectrum to provide continuous and reliable flame detection. The microprocessor in the Model 3100 is config- ured with state-of-the-art fire algorithms and con- tinuously analyzes the data from the sensor array for individual intensity values, change of intensity values, relationship of intensity values and frequency signature correlations. Each algorithm is designed to recognize a different type of flame signature from the detectors while rejecting common false sources. When the conditions of any one of the several fire algorithms are met the Model 3100 declares a fire.

1.2 Fault Diagnostics

The micro-processor is also continuously perform- ing system tests looking for any faults which would impair its ability to accurately detect a flame and declare an alarm. The systems being tested include: input power, sensor circuits, relay circuits, and sev- eral other internal systems. The Model 3100 Flame Detector also performs a through the lens test of the sensor and lens systems. All faults are recorded in non-volatile memory and may be retrieved by a trained technician.

FIGURE 1-1: Model 3100 Series Flame Detector

1.3 Configuration

The Model 3100-01 has a Fire Relay and a Fault Relay which may be connected as normally open or normally closed contacts. Models 3100-02, -03, - 04, and -05 have in addition to the Fire and Faults relays a Fire Verify system and an Auxiliary Fault system. The Fire Verify system adds a “field ad- justable” level of certainty to the declaration of a verified fire. The Auxiliary Fault system will acti- vate the Aux. Relay for the Lens Test fault. This allows a separate indication for the most common fault (a dirty lens). A technician can know immedi- ately what is wrong and how to fix it (i.e. wipe the lens) without reading codes, consulting manuals, or wading through a process of complex diagnostics. The 3100-06 has an industry standard 4-20 mA out- put and no relays.

The Model 3100 detector is mounted in a NEMA 4X explosion proof housing, rated for Class I Divi- sion 1 & 2 Groups B, C, D, Class II Division 1 & 2 Groups E, F, G, and Class III locations. The elec- tronics are mounted inside an aluminum cup to pro- tect the electronics during installation. All switch settings and indicators are located on the front of the Model 3100 detector module allowing field ad- justments to be made without removing the detec- tor module from the housing.

Each Model 3100 detector is calibrated and tested to respond to a 1 square foot Kerosene fire at 80 feet with a Field-of-View of 120°. The Model 3100 detector has four sensitivity settings and six verify levels.

 

 

Fire

Fault

Verify

Aux.

Model

 

Rela

 

Relay

Relay

Relay

 

 

y

 

 

 

3100-01

 

X

X

None

None

3100-02

 

X

X

N/O

N/C

3100-03

 

X

X

N/C

N/O

3100-04

 

X

X

N/O

N/O

3100-05

 

X

X

N/C

N/C

3100-06

 

4

-20 mA signal only

 

 

Models and Functions

 

Model 3100 Series Flame Detector (11/04)

Page: 1

Image 4
Contents Model Model Table of Contents Fault Diagnostics IntroductionModel 3100 Series Field of View GeneralConfiguration See Figure SW1 SW2 SW3 SW4 SW5 SW9 SW8SW7 SW1 Shown in off position SW6 SW2 Shown in on position Field-of-View See FigureLED Fault NormalFire Relay operation See FigureFault Relay Auxiliary FaultVerify Relay 5 4-20 mA OperationGeneral Precautions Housing and Conduit Mounting the HousingInstalling the Conduit and Wiring PowerAuxiliary Relay 6 4-20 mA ConnectionsTroubleshooting Model 3100 Series Flame Detector 11/04 Dimensions Weight Limited WarrantyField of View Responsivity Input voltage LEDs RelaysFigure A-1 Model 3100 Series Exploded View Figure A-3 Model 3100 Series Common Wiring Connections Figure A-4 Model 3100 Series Enhanced Wiring Connections Appendix B Tables Verify Control 3100-02, -03, -04 and -05 Models onlyFire OutputLatching Control Detector Non-Latching ControlConnectors Fire Relay Connector Verify and Aux. Fault ConnectorFault Connector Power/Communications ConnectorFalse Alarm Stimuli Table Fire and False Alarm Stimuli TableDetector Response to Fuels Table Appendix C -- Wiring Connections Index Model 3100 Series Flame Detector 11/04