BEFORE CALLING FOR SERVICE

BEFORE CALLING FOR SERVICE

If the unit appears to be malfunctioning, check the following points before calling for a service.

AIR CONDITIONER DOES NOT OPERATE AT ALL

Is the unit plugged in or is the plug loose?

Has the fuse blown or is the circuit breaker tripped?

Did you restart the unit within 3 minutes of a power failure?

If the power was off for less than 3 minutes when, you restarted the air conditioner, a protective device may cause the compressor to shut off, preventing cooling for about 5 minutes.

Are the OPERATION, TIMER and MEGA COOL lamps blinking? The water tank inside the unit is full. It must be drained.

Check the power plug.

AIR CONDITIONER DOES NOT COOL PROPERLY

Is it set to FAN, DEHUMIDIFICATION or VENTILATION mode?

Cooling does not take place in these modes. Change the MODE setting.

Is the fi lter clogged with dust? Clean the fi lter.

Is the cooling coil frozen?

No air will blow out if the cooling coil is frozen.

Run the air conditioner in FAN mode with the fan speed set to "HIGH" until all ice dissipates.

Is the temperature set properly?

Is the window exposed to direct sunlight?

Close the curtains or blinds to minimize solar energy heating the room.

Is the exhaust hose too long?

For effi cient operation, make the hose as short as possible. The exhaust hose must not be twisted or bent.

SOUNDS

The unit may seem rather loud for the fi rst 2 to 3 minutes when the unit is turned on. This is the sound of the compressor starting-up and is perfectly normal.

A soft, swishing noise can be heard immediately after the unit is turned on or off, and also during operation. This is the sound of the refrigerant fl owing inside the unit.

A low buzzing noise is emitted when the unit is generating Plasmacluster ions.

This air conditioner evaporates water condensed during cooling operation within the unit through the exhaust air outlet. Although water fl owing sound may be heard, this is normal.

An audible gurgling sound may be heard when the unit is operated on a gently sloping floor. Place the unit on a level floor.

TIMER DOES NOT WORK PROPERLY

If a power failure occurs while the TIMER is set, the TIMER setting will be cancelled and will not be retrieved even after the power is restored. This is normal for this unit.

THE UNIT FAILS TO REACT TO THE REMOTE CONTROL SIGNAL

Check the batteries in the remote control. Replace if necessary.

Try to send the signal again with the remote control pointed directly at the unit’s signal receiver window.

Check whether the remote control batteries are installed with the polarities properly aligned.

THE DISCHARGED AIR HAS AN ODOR

Plasmacluster ion generator emit small traces of ozone which may produce an odor. These ozone emissions are below safety levels.

E-23

Image 24
Contents CV-P10LJ CV-P13LJ PORTABLE TYPE ROOM AIR CONDITIONEREN GLI SH ES PA ÑO L CONTENTS USAGE CAUTIONS NOTES ON OPERATIONPRECAUTIONS LOCATIONKeep the filter clean Turn off the air conditioner when no one is homeSUGGESTED TOOLS FOR WINDOW PANEL INSTALLATION INCLUDED3. Knife or scissors PART NAMES FRONT VIEW REAR VIEW33 Horizontal louvers 44 POWER Button 55 Remote control signal receiver windowREMOTE CONTROL REMOTE CONTROL DISPLAY1 1 Transmitter 2 Display 3 POWER Button 79 ON TIMER ButtonINSTALL WINDOW PANEL Installation in a double-hungsash windowAdjustment panel 24~36.8 Extension panel 36.8~48 Foam seal A adhesive type BracketInstallation in a sliding sash window INSTALL WINDOW PANELE-10 INSTALLATION AND REMOVAL OF EXHAUST HOSE Installation of the exhaust hoseE-11 Unacceptable Acceptable AcceptableRemoval of the exhaust hose E-12PUSH Projection PRE-OPERATIONCHECKS E-13LOADING BATTERIES Use two AAA R03 batteries HOW TO USE THE REMOTE CONTROL E-14COOL MODE DEHUMIDIFICATION MODEE-15 2 Press the POWER button to start opera- tionE-16 TO TURN OFF Press the POWER button againTO TURN OFF Press the POWER button again Press the POWER button to start operationTO CHANGE AIR FLOW DIRECTION UP / DOWN AIR FLOW DIRECTIONLEFT / RIGHT AIR FLOW DIRECTION E-17PLASMACLUSTER OPERATION E-18TO CANCEL Press the PLASMACLUSTER button duringMEGA COOL OPERATION SLEEP OPERATIONE-19 TO CANCELTIMER OPERATION ON TIMEROFF TIMER E-20MAIN UNIT OPERATION DRAINAGEE-21 Press the POWER button on the unitMAINTENANCE CLEANING THE FILTERCLEANING THE UNIT AND THE REMOTE CONTROL MAINTENANCE AFTER AIR CONDITIONER SEASONBEFORE CALLING FOR SERVICE E-23TIMER DOES NOT WORK PROPERLY AIR CONDITIONER DOES NOT OPERATE AT ALLE-24 Technical SpecificationsE-25 CompressorEvaporator CondenserE-26 Technical SpecificationsE-27 CompressorEvaporator CondenserWARRANTY Consumer Electronic ProductsCongratulations on Your Purchase DO NOT RETURN THIS DOCUMENT TO SHARPSHARP APPROVED SERVICE CENTRE SHARP APPROVED SERVICE CENTRESHARP CUSTOMER SERVICES 1300Page 66129905937