Sharp CV-P10LJ, CV-P13LJ operation manual Usage Cautions, Notes On Operation

Page 3
USAGE CAUTIONS

USAGE CAUTIONS

Ventilate the room periodically during use, especially if using gas appliances.

Be sure to turn the unit off and disconnect the power supply cord before performing any mainte- nance or cleaning.

Do not splash or pour water directly onto the unit. Water can cause electrical shock or equipment damage.

Drainage should be performed whenever moving the air conditioner. If any water remains in the tank, it may spill out while being moved.

Remove the window panel and close the window in the event of particularly adverse weather. Extremely adverse weather may cause water to leak in through the openings.

To ensure proper drainage, the drainage hose must have no kinks or be on a different level during dehumidification mode.

The drained water may spill out into the room.

The temperature around the drainage hose must not be below freezing point when used. Drained water may freeze inside the hose, causing water inside the unit to overfl ow into the room.

Do not block the exhaust air outlet with obstacles. . Cooling performance may be reduced or stop completely

NOTES ON OPERATION

Allow 3 minutes for the compressor to restart cooling.

If you turn the air conditioner off and immediately restart it, allow three minutes for the compressor to restart cooling. There is an electronic device in the unit that keeps the compressor turned off for three minutes for safety.

In the event of a power failure during use, allow 3 minutes before restarting the unit.

After power is reinstated, restart the air conditioner. If the power was off for less than three minutes, be sure to wait at least three minutes before restarting the unit. If you restart the air conditioner within three minutes, a protective device in the unit may cause the compressor to shut off. This protective device will prevent cool- ing for about 5 minutes. Any previous settings will be canceled and the unit will return to its initial settings.

Low temperature operation: Is your unit freezing up?

Freezing may occur when the unit is set close to 18°C in low ambient temperature conditions, especially at night.

In these conditions, a further temperature drop may cause the unit to freeze. Setting the unit to a higher temperature will prevent it from freezing.

Dehumidification mode increases room temperature.

The unit generates heat during dehumidifi cation mode and the room temperature will rise. Warm air will be blown out from the Exhaust air outlet, but this is normal and does not indicate a problem with the unit.

This air conditioner blows the warm air generated by the unit outside the room via the exhaust hose while in cool mode.

Accordingly, the same amount of air as that blown out will enter the room from outside through any openings into the room.

When cooling operation is performed at high humidity conditions, water tank inside the unit may fre- quently become full.

When water tank inside the unit is full, the unit stops operating and TIMER, OPERATION and MEGA COOL lamps will blink. In this case, perform drainage to drain out water within the unit.

E-2

Image 3
Contents CV-P10LJ CV-P13LJ PORTABLE TYPE ROOM AIR CONDITIONEREN GLI SH ES PA ÑO L CONTENTS NOTES ON OPERATION USAGE CAUTIONSTurn off the air conditioner when no one is home PRECAUTIONSLOCATION Keep the filter cleanSUGGESTED TOOLS FOR WINDOW PANEL INSTALLATION INCLUDED3. Knife or scissors 55 Remote control signal receiver window PART NAMESFRONT VIEW REAR VIEW 33 Horizontal louvers 44 POWER Button79 ON TIMER Button REMOTE CONTROLREMOTE CONTROL DISPLAY 1 1 Transmitter 2 Display 3 POWER ButtonInstallation in a double-hungsash window INSTALL WINDOW PANELFoam seal A adhesive type Bracket Adjustment panel 24~36.8 Extension panel 36.8~48INSTALL WINDOW PANEL Installation in a sliding sash windowE-10 Unacceptable Acceptable Acceptable INSTALLATION AND REMOVAL OF EXHAUST HOSEInstallation of the exhaust hose E-11Removal of the exhaust hose E-12PUSH Projection PRE-OPERATIONCHECKS E-13LOADING BATTERIES Use two AAA R03 batteries E-14 HOW TO USE THE REMOTE CONTROL2 Press the POWER button to start opera- tion COOL MODEDEHUMIDIFICATION MODE E-15Press the POWER button to start operation E-16TO TURN OFF Press the POWER button again TO TURN OFF Press the POWER button againE-17 TO CHANGE AIR FLOW DIRECTIONUP / DOWN AIR FLOW DIRECTION LEFT / RIGHT AIR FLOW DIRECTIONPress the PLASMACLUSTER button during PLASMACLUSTER OPERATIONE-18 TO CANCELTO CANCEL MEGA COOL OPERATIONSLEEP OPERATION E-19E-20 TIMER OPERATIONON TIMER OFF TIMERPress the POWER button on the unit MAIN UNIT OPERATIONDRAINAGE E-21MAINTENANCE AFTER AIR CONDITIONER SEASON MAINTENANCECLEANING THE FILTER CLEANING THE UNIT AND THE REMOTE CONTROLAIR CONDITIONER DOES NOT OPERATE AT ALL BEFORE CALLING FOR SERVICEE-23 TIMER DOES NOT WORK PROPERLYTechnical Specifications E-24Condenser E-25Compressor EvaporatorTechnical Specifications E-26Condenser E-27Compressor EvaporatorDO NOT RETURN THIS DOCUMENT TO SHARP WARRANTYConsumer Electronic Products Congratulations on Your Purchase1300 SHARP APPROVED SERVICE CENTRESHARP APPROVED SERVICE CENTRE SHARP CUSTOMER SERVICESPage 66129905937