Aegis Micro NRC 2.0.1 manual Hardware Installation

Page 12

Hardware Installation

Step 1: Receiver Audio Signal Termination Type

The NRC supports both differential and single-end audio signals, with the factory system default being configured to support Differential Mode.

If Single-End mode is required, proceed as follows:

1.Ensure the NRC is powered off

2.Remove the top cover of the NRC.

3.Locate the two banks of 4x DIP switches, D1 and D2.

4.Set all switches to the ON position for single-ended operation.

a. Conversely, set each switch to the OFF position for differential operation.

5.Replace the cover and install the screws.

Note: The NRC software’s default configuration is to support Differential Mode, and hence it must also be configured to match the desired audio signal state. The NRC Configuration section will address this requirement.

Step 2: Rack Mount the NRC unit

The NRC chassis supports Jonathan Type 375QD-20 chassis slides and these are recommended for rack mounting the NRC where necessary.

Note: It is not recommended that the NRC Chassis be solely mounted in 19” rack by bolts through the chassis’ front panel - rack slides or rack shelving recommended.

Step 3: Connect Power

The supplied power cable should connect the power adapter on the back panel power socket of the NRC. The NRC power supply is an auto-sensing unit which can accept voltages between 100-240VAC @47-63Hz.

Step 4: Connect Receivers

Each brand and model of receiver has specific configuration and installation instructions that must be followed prior to operation with the NRC. Please refer to Appendix A.

Step 5: Optional - Connect an External Clock

If an external clock connection is desired for A/D synchronization, use a coaxial cable to connect a 16 KHz TTL (50% duty cycle) external clock signal to the EXT CLK port on the NRC’s back.

The NRC’s default configuration uses the internal clock and hence the system needs to be re- configured to use an external signal for A/D synchronization. This can be achieved after the Hardware Installation through the NRC Java client’s “ Global NRC Properties” dialog, or via the programmers’ SDK.

Step 6: Connect to the Network

A Cat-5 cable should be used to connect between the ETH port on the back panel of the NRC and the local area network.

Users’ Guide: Networked Receiver Controller - NRC-2.0.1

PAGE 12

11th October 2005

Copyright © 2005 Aegis, Inc

wwww.aegis-inc.net [ph. 240-568-9006]

Image 12
Contents Networked Receiver Controller NRC-2.0.1 Proprietary Statement Table of Contents TEN-TEC RX-331 General Information Channel Architecture Audio Data CaptureUniversal Receiver Translation/Abstraction Receiver Controllable Settings Client Connection Options Capabilities SummarySpecifications System Hardware Supported ReceiversTh October Copyright 2005 Aegis, Inc Installation ContentsHardware Installation NRC Configuration PrerequisitesConnect to the NRC Change Administrator Password Configure Network Settings Set the Time and DateConfigure the Network Time Daemon Optional Set the Host Name Restart the NRCUsers’ Guide Networked Receiver Controller NRC-2.0.1 Configure the NRC for Receivers Using the NRC Power-On Self Test PostStarting the NRC Interpreting the LCD DisplayUsers’ Guide Networked Receiver Controller NRC-2.0.1 Requirements Running the NRC Java Client Connect to NRC Server DialogTree Main Application WindowContent Panel NRC Servers NodeUsers’ Guide Networked Receiver Controller NRC-2.0.1 Channel Node Users’ Guide Networked Receiver Controller NRC-2.0.1 Users’ Guide Networked Receiver Controller NRC-2.0.1 Toolbar Status Bar Change Receiver Model Dialog Change Antenna Model Dialog NRC Properties Dialog Destination OptionsCapture Channel Data Dialog Signal Display Dialog Th October Copyright 2005 Aegis, Inc Appendix A- Receiver Configuration BAE Systems WJ-8723Appendix B Software Upgrades NRC File SystemUpdate Command Restore CommandClean Command Upgrade ProcedureUsers’ Guide Networked Receiver Controller NRC-2.0.1 Users’ Guide Networked Receiver Controller NRC-2.0.1