Agilent Technologies 5962-8200 service manual Control Circuits

Page 46

4 - Principles of Operation

As shown in Figure 6-2, the ac input rectifier and filter converts ac input to a dc level. The output regulator regulates this dc level at the output of the power supply. The output regulator stage consists of two parallel NPN series regulators mounted on a heatsink and connected between the +Rail and the +Output. The conduction of these series regulators is increased or decreased by the Control signal from the CV/CC control circuits in order to regulate the output voltage (in CV mode), or output current (in CC mode).

An NPN downprogramming transistor is connected between the +Output and the -Rail. The conduction of the downprogramming transistor is controlled by the DP_Control signal from the CV/CC control circuits. Whenever the output voltage is greater than the programmed voltage setting, the downprogramming transistor conducts and shunts current away from the load until the output voltage equals the programmed setting.

The SCR, connected across the output, will fire and short the output when an overvoltage condition is detected. The SCR is controlled by the OV_SCR* signal from the crowbar control circuit (described in the next section).

Two current shunt resistors (RmHi and RmLo) monitor the output current. RmHi monitors the high current range; RmLo monitors the low current range. Shunt clamps are connected in parallel across RmLo to limit the voltage across RmLo to about 2 volts. This corresponds to approximately 25 mA (the maximum rating of the low current range).

The output filter capacitor provides additional filtering of the dc output.

Control Circuits

As shown in Figure 6-2, the control circuits consist of the CV/CC control, output voltage/current monitor, bias supplies, and SCR control.

The CV/CC control circuits provide a CV control loop and a CC control loop. For any value of load resistance, the supply must act either as a constant voltage (CV) or as a constant current (CC) supply. Transfer between these modes is accomplished automatically by the CV/CC control circuit at a value of load resistance equal to the ratio of the programmed voltage value to the programmed current value. A low level CV_Detect* or CC_Detect* signal is returned to the secondary interface to indicate that the corresponding mode is in effect.

With the CV loop in control, the output voltage is regulated by comparing the programmed voltage signal CV_Prog (0 to -5V) with the output voltage monitor signal VMon. The VMon signal is in the 0 to +5 V range, which corresponds to the zero to full-scale output voltage range of the supply. If the output voltage exceeds the programmed voltage, the Control signal goes low, causing the output regulator to conduct less and decrease the output voltage. Conversely, if the output voltage is less than the programmed voltage, the Control signal goes high, causing the regulator to conduct more and increase the output voltage. Depending upon the position of the Sense switch, the output voltage is either monitored at the supply's output terminals (local), or at the load (remote), using the +S and -S terminals with remote sense leads connected to the load. If the output voltage goes higher than the programmed value, the downprogramming stage is turned on.

With the CC loop in control, the output current is regulated by comparing the programmed current signal CC_Prog (0 to -5V), with the output current monitor signal Imon_H. The Imon_H signal is produced by measuring the voltage drop across current monitoring resistor and is in the 0 to +3.5 V range, which corresponds to the zero to full-scale output current range. If the output current exceeds the programmed value, the Control signal goes low, causing the output regulator to conduct less and thus decrease the output current. Conversely, if the output current is less than the programmed value, the Control signal goes high, causing the output transistors to conduct more and increase the output current. A gross current limit circuit protects the output if the output current exceeds the maximum current rating of the unit.

46

Image 46
Contents Agilent Part No Microfiche No September Warranty Information CertificationSafety Summary Before Applying PowerSafety Symbol Definitions Symbol DescriptionPrinting History Instrument IdentificationTable of Contents Post-repair Calibration Initialization ROM UpgradeDisassembly Procedures IntroductionPage Related Documents Safety ConsiderationsOrganization ChapterManual Revisions RevisionsElectrostatic Discharge Firmware RevisionsIntroduction Test Equipment RequiredType Specifications Recommended Model Test SetupMeasurement Techniques Test Setup Electronic LoadCurrent-Monitoring Resistor Operation Verification TestsPerformance Tests ProgrammingVoltage Programming and Readback Accuracy CV SetupConstant Voltage CV Tests CV Load EffectCV Source Effect Transient Recovery TimeCV Noise Pard Constant Current CC Tests CC SetupCurrent Programming and Readback Accuracy Current Sink -CC Operation Low Range Current Readback AccuracyCC Load and Line Regulation CC Load EffectCC Source Effect CC Noise PardPerformance Test Equipment Form Constant Current Tests Current Programming and Readback Load Effect Source Effect Pard Ripple and NoiseTransient Response Current Sink @ -3A Readback MA Range Current ReadbackSource Effect Vout − Vout −Load Effect Vout − Vout + 2.0mV Iout −Iout − Iout + 2.2 mA Vout + 4 mVIout − Iout + 0.2 mA Current Sink @ -0.6A Readback Iout −Iout − Iout + 1.1 mA Load Effect Vout − Vout + 5 mVIout − Iout + 0.1 mA Current Sink @ -0.3A Readback Iout −Page Troubleshooting Test Equipment Required for Troubleshooting Overall TroubleshootingFlow Charts Type Purpose Recommended ModelSheet 1. Troubleshooting Flowchart Sheet 2. Troubleshooting Flowchart Sheet 3. Troubleshooting Flowchart Sheet 4. Troubleshooting Flowchart Self-Test Error Codes/Messages Specific Troubleshooting ProceduresPower-on Self-test Failures Error Code Description Probable CauseBias and Reference Voltages CV/CC Status Annunciators TroubleshootingBias and Reference Supplies Bias Test Point MeasurementJ307 Voltage Measurements Voltage Measurements at J207 A2 Interface to A1 Main boardDisabling Protection Features Manual Fan Speed ControlCalibration Password Inhibit Calibration SwitchPost-repair Calibration Initialization ROM UpgradeUpgrade Procedure Identifying the FirmwareDisassembly Procedures List of Required ToolsA2 Interface Board, Removal and Replacement Cover, Removal and ReplacementFront Panel Assembly, Removal and Replacement T1 Power Transformer, Removal and Replacement A3 Front Panel Board, Removal and ReplacementA1 Main Control Board Line Voltage Wiring Power Supply Interface signals Interface SignalsConnector Signal Description Primary Interface A3 Front Panel CircuitsA2 Interface Circuits Secondary InterfacePower Circuits A1 Main Board CircuitsControl Circuits Principles of Operation Page Chassis, Electrical Designator PartNumber Qty DescriptionReplaceable Parts List Mechanical Parts Identification Chassis, Mechanical MP9Diagrams Diagrams A2/A3 Boards Block Diagram Bias CircuitsIndex Index