Systems Insight Display LED | Health LED | System power LED | Status | |
and color |
|
|
|
|
|
|
|
| |
Over temp (amber) | Amber | Green | The Health Driver has | |
|
|
| detected a cautionary | |
|
|
| temperature level. | |
|
|
|
| |
Over temp (amber) | Red | Amber | The server has detected a | |
|
|
| hardware critical temperature | |
|
|
| level. | |
|
|
|
| |
PCI riser (amber) | Red | Green | The PCI riser cage is not | |
|
|
| seated properly. | |
|
|
|
| |
Fan (amber) | Amber | Green | One fan has failed or has | |
|
|
| been removed. | |
|
|
|
| |
Fan (amber) | Red | Green | Two or more fans have failed | |
|
|
| or been removed. | |
|
|
|
| |
Power supply (amber) | Red | Amber | One or more of the following | |
|
|
| conditions may exist: | |
|
|
| ● Only one power supply | |
|
|
|
| is installed and that |
|
|
|
| power supply is in |
|
|
|
| standby. |
|
|
| ● | Power supply fault |
|
|
| ● | System board fault |
|
|
|
| |
Power supply (amber) | Amber | Green | One or more of the following | |
|
|
| conditions may exist: | |
|
|
| ● | Redundant power |
|
|
|
| supply is installed and |
|
|
|
| only one power supply |
|
|
|
| is functional. |
|
|
| ● AC power cord is not | |
|
|
|
| plugged into redundant |
|
|
|
| power supply. |
|
|
| ● | Redundant power |
|
|
|
| supply fault |
|
|
| ● | Power supply mismatch |
|
|
|
| at POST or power |
|
|
|
| supply mismatch |
|
|
|
| through |
|
|
|
| addition |
|
|
|
| |
Power cap (off) | — | Amber | Standby | |
|
|
|
| |
Power cap (green) | — | Flashing green | Waiting for power | |
|
|
|
| |
Power cap (green) | — | Green | Power is available. | |
|
|
|
| |
Power cap (flashing amber) | — | Amber | Power is not available. | |
|
|
|
|
|
IMPORTANT: If more than one DIMM slot LED is illuminated, further troubleshooting is required. Test each bank of DIMMs by removing all other DIMMs. Isolate the failed DIMM by replacing each DIMM in a bank with a known working DIMM.
6Chapter 2 Component identification