FlexibleLOM option
WARNING! To reduce the risk of personal injury, electric shock, or damage to the equipment, remove the power cord to remove power from the server. The front panel Power On/Standby button does not completely shut off system power. Portions of the power supply and some internal circuitry remain active until AC power is removed.
1. Power down the server on page 18.
2. Remove all power:
a. Disconnect each power cord from the power source. b. Disconnect each power cord from the server.
3. Remove any attached network cables.
4. Extend the server from the rack on page 19.
5.Remove the access panel on page 20.
6.Loosen the thumbscrew.
7.Remove the existing FlexibleLOM.
To replace the component:
1. Firmly seat the FlexibleLOM in the slot, and then tighten the thumbscrew.
60 Chapter 5 Hardware options installation