1 – Amber | 2 - Green | 3 - Green | Interpretation |
|
|
|
|
Flashing 1 Hz | On | Off | An overtemperature |
|
|
| condition exists. |
|
|
|
|
Flashing 2 Hz | Flashing 2 Hz | Off | The capacitor pack is not |
|
|
| attached. |
|
|
|
|
Flashing 2 Hz | Flashing 2 Hz | On | The capacitor has been |
|
|
| charging for 10 minutes, but |
|
|
| has not reached sufficient |
|
|
| charge to perform a full |
|
|
| backup. |
|
|
|
|
On | On | Off | The current backup is |
|
|
| complete, but power |
|
|
| fluctuations occurred during |
|
|
| the backup. |
|
|
|
|
On | On | On | The cache module |
|
|
| microcontroller has failed. |
|
|
|
|
Hot-plug fans
CAUTION: To avoid damage to server components, fan blanks must be installed in fan bays 1 and 2 in a
The only two valid fan configurations are listed in the following table.
Configuration | Fan bay 1 | Fan bay 2 | Fan bay 3 | Fan bay 4 | Fan bay 5 | Fan bay 6 |
|
|
|
|
|
|
|
1 processor | Fan blank | Fan blank | Fan | Fan | Fan | Fan |
|
|
|
|
|
|
|
2 processors | Fan | Fan | Fan | Fan | Fan | Fan |
|
|
|
|
|
|
|
For a
16 Chapter 2 Component identification