HP Security Camera ML100 Installing hardware options, Powering up and configuring the server

Page 10

WARNING: To reduce the risk of personal injury or damage to the equipment, be sure that:

The leveling jacks are extended to the floor.

The full weight of the rack rests on the leveling jacks.

The stabilizing feet are attached to the rack if it is a single-rack installation.

The racks are coupled together in multiple-rack installations.

Only one component is extended at a time. A rack may become unstable if more than one component is extended for any reason.

WARNING: To reduce the risk of personal injury or equipment damage when unloading a rack:

At least two people are needed to safely unload the rack from the pallet. An empty 42U rack can weigh as much as 115 kg (253 lb), can stand more than 2.1 m (7 ft) tall, and might become unstable when being moved on its casters.

Never stand in front of the rack when it is rolling down the ramp from the pallet. Always handle the rack from both sides.

Installing hardware options

Install any hardware options before initializing the server. For options installation information, refer to the option documentation. For server-specific information, refer to "Hardware options installation (on page 11)."

Powering up and configuring the server

To power up the server, press the Power On/Standby button.

For detailed information on configuring the server, see the server installation sheet.

Installing the operating system

To operate properly, the server must have a supported operating system. For the latest information on supported operating systems, refer to the HP website (http://www.hp.com/go/supportos).

To install an operating system on the server, insert the operating system CD into the CD-ROM drive and reboot the server. This process may require you to obtain additional drivers from the Easy Set-up CD or the support CD shipped with the server, or the CD that shipped with the option. The drivers may have updates that are available on the HP website (http://www.hp.com/support).

Follow the on-screen instructions to begin the installation process.

Registering the server

To register the server, refer to the HP Registration website (http://register.hp.com).

Server setup 10

Image 10
Contents HP ProLiant ML100 Series Server User Guide Page Contents Troubleshooting Support and other resources 103 Power down the server Power up the serverServer operations Rack planning resources Server setup Optional installation services Optimum environmentTemperature requirements Rack warnings Power requirementsElectrical grounding requirements Installing the operating system Installing hardware optionsPowering up and configuring the server Registering the serverIntroduction Hardware options installationAccess panel Processor optionHardware options installation Hardware options installation Hardware options installation Hardware options installation Hardware options installation Hardware options installation Hardware options installation Hardware options installation SAS or Sata hard drive options Remove the hard drive blank Prepare the hard drive Hard drive LED cable option Installing the LED cable ML110 G4 Hardware options installation Hardware options installation Installing the LED cable ML150 G3 Hardware options installation Installing the LED cable ML110 G5, ML115 G5, and ML150 G5 Connector locations ML110 G5, ML115 G5, and ML150 G5Hardware options installation Hardware options installation HP Smart Array E200 controller card Hardware options installation Installing media devices with rails Removable media device optionsInstalling media devices with screws Hardware options installation Installing media devices with a media latch Installing media devices with wire retainers Installing a half-height media deviceInstalling a full-height media device Hardware options installation Installing DIMMs Interleaving and non-interleaving memory configurationMemory options Installing an expansion board with a single retainer Expansion board optionsHardware options installation Installing an expansion board with individual retainers Installing an expansion board with an external retainer Hardware options installation Hardware options installation ROMPaq utility Server software and configuration utilitiesHP Insight Diagnostics Keeping the system currentDiskette and CD-ROM drive options Embedded Sata RAID featureRequired hardware HP Integrated Lights-Out Virtual Floppy and CD-ROM drivesEnabling Sata RAID functionality in the Bios Setup Utility Configuring the Sata RAID featureProLiant ML110 Generation 3 Server ProLiant ML150 Generation 5 Servers Creating a RAID volume ProLiant ML115 and ML115 G5 ServersUSB diskette and CD-ROM drives DOSInstalling a supported Microsoft Windows OS Installing an operating systemInstalling a supported Linux or NetWare OS Important safety information TroubleshootingPre-diagnostic steps Important safety informationTroubleshooting Symptom information Preparing the server for diagnosisService notifications Firmware updates Common problem resolutionLoose connections SAS and Sata hard drive guidelines Dimm handling guidelinesHard drive guidelines Scsi hard drive guidelinesHot-plug Scsi hard drive LED combinations SAS and Sata hard drive LED combinationsTroubleshooting flowcharts Start diagnosis flowchartGeneral diagnosis flowchart SeeGeneral memory problems are occurring on Power-on problems flowchart Support CD, or the HP website Post problems flowchart Symptom information on OS boot problems flowchart Server fault indications flowchart Support CD, or the HP website Hardware problems Power supply problems Power problemsPower source problems UPS problemsLow battery warning is displayed General hardware problemsProblems with new hardware One or more LEDs on the UPS is redUnknown problem CD-ROM and DVD drive problems Internal system problemsThird-party device problems Testing the deviceDrive is not detected DAT drive problemsDAT drive is providing poor performance Diskette drive problems DLT drive failure occurs DLT drive problemsServer cannot write to tape DLT drive does not read tapeAn error occurs during backup, but the backup is completed Fan problemsHard drive problems General fan problems are occurringHard drive is not recognized by the server Data is inaccessibleNo hard drives are recognized New hard drive is not recognizedMemory count error exists Memory problemsGeneral memory problems are occurring Server response time is slower than usualServer fails to recognize existing memory PPM problemsProcessor problems Server fails to recognize new memoryVideo problems External device problemsSystem open circuits and short circuits Video colors are wrong Audio problemsSlow-moving horizontal lines are displayed Mouse and keyboard problems Printer problemsModem problems Modem does not answer an incoming call No response occurs when you type AT commandsAT commands are not visible Modem does not connect to another modemNetwork controller problems Network controller has stopped working Software problems Operating system problemsWhen to reconfigure or reload software Operating system updatesRestoring to a backed-up version Firmware maintenance Linux operating systems Application software problemsROMPaq utility diskette or USB drive key Automatic backupTypes of ROM System ROMROMPaq Disaster Recovery Current firmware versionsUpdating firmware Battery replacement Regulatory compliance identification numbers Regulatory compliance noticesFederal Communications Commission notice Cables ModificationsCanadian notice Avis Canadien European Union regulatory notice Japanese notice Bsmi notice Korean notice Taiwan battery recycling notice Battery replacement noticeLaser compliance Regulatory compliance notices Preventing electrostatic discharge Electrostatic dischargeGrounding methods to prevent electrostatic discharge HP contact information Support and other resourcesBefore you contact HP Customer Self RepairRéparation par le client CSR Riparazione da parte del cliente Reparaciones del propio cliente Reparo feito pelo cliente Support and other resources Support and other resources Support and other resources LO100 Acronyms and abbreviationsPCI Express PDU Documentation feedback Index Installing operating system Temperature requirements