HP Security Camera ML100 manual Installing operating system

Page 115

H

hard drive LED cable

24, 27, 29

 

hard drive LEDs

60

 

 

hard drive problems, diagnosing

79

hard drive, failure of

79

 

hard drives, determining status of

60

hard drives, installing

11

 

hardware options

11

 

hardware options installation 10, 11

hardware problems

71, 73

 

hardware troubleshooting 73, 74, 75, 83 hot fixes 90

HP Insight Diagnostics 48 HP technical support 103 HP website 103

I

identification number 96

Important Safety Information document 55

Insight Diagnostics

48

 

installation, server options

10, 11

installing hardware

11

 

installing operating system

10, 54

internal system problems

75

J

Japanese notice 99

K

keyboard 85 keyboard problems 85 Korean notices 99 KVM 84, 85

L

laser compliance 100 laser devices 100 LEDs 73

LEDs, hard drive 60 LEDs, PPM failure 82 LEDs, processor failure 82 LEDs, troubleshooting 55, 60 LEDS, UPS 72

Linux 54, 91

loose connections 58

M

media devices, installing, with a media latch

37

media devices, installing, with rails 34

 

media devices, installing, with screws 35

 

media devices, installing, with wire retainers

38

memory

41, 81

 

 

 

memory count error 81, 82

 

memory not recognized 82

 

memory overview

41

 

 

memory problems

81

 

 

memory, interleaving 41

 

 

Microsoft operating systems

54

 

modem problems

85

 

 

modems

85, 86

 

 

 

modifications, FCC notice

97

 

monitor

84

 

 

 

mouse

85

 

 

 

mouse problems

85

 

 

N

network controller problems 87 network controllers 87, 88, 89 network interconnect blades 89

O

operating system crash 89 operating system problems 89 operating system updates 90 operating systems 10, 89, 90, 91 optimum environment 7 Optional Installation Services 7 options installation 10, 11

P

patches 90

 

PCI boards 75

 

phone numbers

103

power cord 56, 101

power distribution unit (PDU) 9

Power On button

6

power problems

72

power requirements 9

power source 72

power supplies

72

powering down

6

PPM (processor power module) 82

PPM failure LEDs 82

PPM problems 82

Index 115

Image 115
Contents HP ProLiant ML100 Series Server User Guide Page Contents Troubleshooting Support and other resources 103 Power down the server Power up the serverServer operations Optimum environment Server setupOptional installation services Rack planning resourcesTemperature requirements Rack warnings Power requirementsElectrical grounding requirements Registering the server Installing hardware optionsPowering up and configuring the server Installing the operating systemProcessor option Hardware options installationAccess panel IntroductionHardware options installation Hardware options installation Hardware options installation Hardware options installation Hardware options installation Hardware options installation Hardware options installation Hardware options installation SAS or Sata hard drive options Remove the hard drive blank Prepare the hard drive Hard drive LED cable option Installing the LED cable ML110 G4 Hardware options installation Hardware options installation Installing the LED cable ML150 G3 Hardware options installation Connector locations ML110 G5, ML115 G5, and ML150 G5 Installing the LED cable ML110 G5, ML115 G5, and ML150 G5Hardware options installation Hardware options installation HP Smart Array E200 controller card Hardware options installation Removable media device options Installing media devices with railsInstalling media devices with screws Hardware options installation Installing media devices with a media latch Installing a half-height media device Installing media devices with wire retainersInstalling a full-height media device Hardware options installation Installing DIMMs Interleaving and non-interleaving memory configurationMemory options Expansion board options Installing an expansion board with a single retainerHardware options installation Installing an expansion board with individual retainers Installing an expansion board with an external retainer Hardware options installation Hardware options installation Keeping the system current Server software and configuration utilitiesHP Insight Diagnostics ROMPaq utilityHP Integrated Lights-Out Virtual Floppy and CD-ROM drives Embedded Sata RAID featureRequired hardware Diskette and CD-ROM drive optionsEnabling Sata RAID functionality in the Bios Setup Utility Configuring the Sata RAID featureProLiant ML110 Generation 3 Server ProLiant ML150 Generation 5 Servers ProLiant ML115 and ML115 G5 Servers Creating a RAID volumeDOS USB diskette and CD-ROM drivesInstalling a supported Microsoft Windows OS Installing an operating systemInstalling a supported Linux or NetWare OS Important safety information TroubleshootingPre-diagnostic steps Important safety informationTroubleshooting Preparing the server for diagnosis Symptom informationService notifications Firmware updates Common problem resolutionLoose connections Scsi hard drive guidelines Dimm handling guidelinesHard drive guidelines SAS and Sata hard drive guidelinesSAS and Sata hard drive LED combinations Hot-plug Scsi hard drive LED combinationsStart diagnosis flowchart Troubleshooting flowchartsSee General diagnosis flowchartGeneral memory problems are occurring on Power-on problems flowchart Support CD, or the HP website Post problems flowchart Symptom information on OS boot problems flowchart Server fault indications flowchart Support CD, or the HP website Hardware problems UPS problems Power problemsPower source problems Power supply problemsOne or more LEDs on the UPS is red General hardware problemsProblems with new hardware Low battery warning is displayedUnknown problem Testing the device Internal system problemsThird-party device problems CD-ROM and DVD drive problemsDrive is not detected DAT drive problemsDAT drive is providing poor performance Diskette drive problems DLT drive does not read tape DLT drive problemsServer cannot write to tape DLT drive failure occursGeneral fan problems are occurring Fan problemsHard drive problems An error occurs during backup, but the backup is completedNew hard drive is not recognized Data is inaccessibleNo hard drives are recognized Hard drive is not recognized by the serverServer response time is slower than usual Memory problemsGeneral memory problems are occurring Memory count error existsServer fails to recognize new memory PPM problemsProcessor problems Server fails to recognize existing memoryVideo problems External device problemsSystem open circuits and short circuits Video colors are wrong Audio problemsSlow-moving horizontal lines are displayed Mouse and keyboard problems Printer problemsModem problems Modem does not connect to another modem No response occurs when you type AT commandsAT commands are not visible Modem does not answer an incoming callNetwork controller problems Network controller has stopped working Operating system problems Software problemsWhen to reconfigure or reload software Operating system updatesRestoring to a backed-up version Linux operating systems Application software problems Firmware maintenanceSystem ROM Automatic backupTypes of ROM ROMPaq utility diskette or USB drive keyCurrent firmware versions ROMPaq Disaster RecoveryUpdating firmware Battery replacement Regulatory compliance identification numbers Regulatory compliance noticesFederal Communications Commission notice Cables ModificationsCanadian notice Avis Canadien European Union regulatory notice Japanese notice Bsmi notice Korean notice Taiwan battery recycling notice Battery replacement noticeLaser compliance Regulatory compliance notices Preventing electrostatic discharge Electrostatic dischargeGrounding methods to prevent electrostatic discharge Customer Self Repair Support and other resourcesBefore you contact HP HP contact informationRéparation par le client CSR Riparazione da parte del cliente Reparaciones del propio cliente Reparo feito pelo cliente Support and other resources Support and other resources Support and other resources LO100 Acronyms and abbreviationsPCI Express PDU Documentation feedback Index Installing operating system Temperature requirements