HP R7000 manual Specifications, UPS physical specifications, ERM physical specifications

Page 50

Specifications

UPS physical specifications

Parameter

Value

 

 

Height

17.1 cm (6.75 in)

Depth

73.4 cm (28.9 in)

Width

43.7 cm (17.2 in)

Weight

75 kg (165 lb)

Ambient operation

0~40°C

ERM physical specifications

Parameter

Value

 

 

Height

12.7 cm (5 in)

Depth

71.9 cm (28.3 in)

Width

43.8 cm (17.24 in)

Weight

63 kg (139 lb)

UPS input specifications

NOTE: An asterisk (*) indicates the default setting.

UPS model

Utility voltage

Available settings

Dedicated

Line cord

 

 

frequency (Hz)

utility voltage (VAC)

branch circuit

 

 

 

 

 

rating (A)

 

 

 

 

 

 

 

R7000

NA/JPN

50/60

200/208*/220/230/

40

Nondetachable power

 

 

 

240

50 low input

cord with NEMA

 

 

 

 

 

CS8265C plug

 

 

 

 

 

 

R7000

INTL

50/60

200/208/220/230*/

32

Nondetachable power

 

 

 

240

 

cord with 32 A IEC-309

 

 

 

 

 

plug

 

 

 

 

 

 

UPS output specifications

UPS model

Load

Circuit

Output receptacles

Maximum current

 

segment

breaker

 

 

 

 

 

 

 

 

 

R7000 NA/JPN

1

20 A¹

2 x IEC-320-C19

16

A per receptacle²

 

 

 

2 x IEC-320-C13

10

A per receptacle

 

 

 

 

 

 

Specifications 50

Image 50
Contents HP UPS R7000 User Guide Part Number February EditionPage Contents Maintenance Power Protector softwareSpares Overview Important safety informationUPS R7000 features UPS R7000 overviewUPS front panel controls Component identificationUPS front panel DescriptionUPS rear panel Repo port ERM rear panel Preparing to install the hardware Installation and configurationPrecautions Tools and materialsReadying the equipment Installing the mounting railsSelecting a site Hex nuts Cage nuts Cage nut-fitting toolInstallation and configuration Installation and configuration Installation and configuration Preparing the rails for integrated shipping Installing the UPS Connecting the battery leadsInstallation and configuration Configuring a USB to serial converter Reassigning the USB COM ports Installation and configuration Installation and configuration Connecting the ground bonding cable Connecting the network cableConnecting the UPS to utility power Connecting devices to the UPSConnecting the configuration cable Configuring the UPS Network ModuleStarting power to the load Launching a terminal emulation program Configuring the UPS Network Module network settingsBe sure that the UPS is powered on Accessing the web interface Installing the ERM Configuring the UPS Network Module settingsAttaching the ERM front bezel Connecting the ERM to the UPS Charging the ERM batteriesAuto-Bypass mode Standby modeOperate mode UPS operationsChanging display functions Configuring the UPSChanging the language After connecting the Repo port on Verifying the Repo port connectionPowering down the UPS Power management Power Protector softwarePower management Maintenance Important battery safety information Replacing the batteriesBattery care and storage guidelines UPS battery replacement procedureMaintenance Replacing the UPS Disconnect the battery leads Remove the UPS battery bracket Replacing the ERM Updating the UPS firmwareTroubleshooting Alarm troubleshootingAlarm number Alarm name Alarm description Alarm type Silencing an audible alarm Battery connection conditionGeneral alarm condition Bypass is out of range Input voltage is out of range Internal UPS fault condition Low battery shutdowns Insufficient warning of low batteriesUPS frequently switches between utility and battery power Site wiring conditionUPS does not provide the expected backup time Repo conditionUtility power condition UPS is in Auto-Bypass modeUPS is on battery UPS is on bypassERM physical specifications SpecificationsUPS physical specifications UPS input specificationsOutput tolerance specifications Power protection specificationsVoltage specifications Output feature specificationsMinimum battery runtime Battery specificationsAverage battery runtime Environmental specifications Repo port specificationsOrdering spares UPS spare parts listSpares Hardware options$250,000 Computer Load Protection Guarantee Safety and regulatory complianceWarranty information Limited warranty Regulatory informationPre-Failure Battery Warranty Recommended duration of useGrounding methods to prevent electrostatic discharge Electrostatic dischargePreventing electrostatic discharge HP contact information Support and other resourcesBefore you contact HP Acronyms and abbreviations Documentation feedback Index Index