HP R7000 manual Pre-Failure Battery Warranty, Recommended duration of use

Page 56

The UPS is plugged into a suitably grounded and wired outlet using no extension cords, adapters, other ground wires, or other electrical connections.

The UPS installation complies with all applicable electrical and safety codes specified by the NEC.

The UPS is used under normal operating conditions and users comply with all instructions and labels.

The UPS is not damaged by accident (other than a utility power transient), misuse, or abuse. o The Guarantee applies only to the original end-user and is non-transferable.

o The Guarantee does not include reimbursement for or restoration of any data loss.

The UPS is either connected directly to an enterprise class PDU, which is then connected directly to a server, workstation, or personal computer, or the UPS is connected directly to a server, workstation, or personal computer.

Pre-Failure Battery Warranty

The Pre-Failure Battery Warranty, standard on all UPS units, extends the advantage of a 3-year limited warranty by applying it to the battery before it actually fails. The Pre-Failure Battery Warranty ensures that the battery is replaced free of charge when a notification that the battery might fail is received from power protector software. The battery warranty coverage is 3 years for parts. The warranty for the first year of ownership includes parts and labor. If battery spares are not available for a particular UPS model, the entire UPS, including its battery, is replaced.

A Pre-Failure Battery warning is given 30 days before a battery failure. The warning is given in one or both of the following ways:

The display showing the battery is low.

Notification from the power protector software.

Recommended duration of use

Although tests and a multitude of customer experiences have shown no noticeable performance issues with UPSs for significant time periods after expiration of the 3-year limited warranty, HP strongly recommends replacing UPSs after a maximum of 5 to 6 years of use to assure full functionality and a safe operating environment. This recommendation does not extend or in any way alter the warranty for UPSs which is limited to a time period of 3 years and a coverage as stated in the applicable warranty statement.

Regulatory information 56

Image 56
Contents HP UPS R7000 User Guide Part Number February EditionPage Contents Maintenance Power Protector softwareSpares Important safety information UPS R7000 featuresOverview UPS R7000 overviewComponent identification UPS front panelUPS front panel controls DescriptionUPS rear panel Repo port ERM rear panel Installation and configuration PrecautionsPreparing to install the hardware Tools and materialsInstalling the mounting rails Selecting a siteReadying the equipment Hex nuts Cage nuts Cage nut-fitting toolInstallation and configuration Installation and configuration Installation and configuration Preparing the rails for integrated shipping Installing the UPS Connecting the battery leadsInstallation and configuration Configuring a USB to serial converter Reassigning the USB COM ports Installation and configuration Installation and configuration Connecting the ground bonding cable Connecting the network cableConnecting the UPS to utility power Connecting devices to the UPSConnecting the configuration cable Configuring the UPS Network ModuleStarting power to the load Launching a terminal emulation program Configuring the UPS Network Module network settingsBe sure that the UPS is powered on Accessing the web interface Installing the ERM Configuring the UPS Network Module settingsAttaching the ERM front bezel Connecting the ERM to the UPS Charging the ERM batteriesStandby mode Operate modeAuto-Bypass mode UPS operationsChanging display functions Configuring the UPSChanging the language After connecting the Repo port on Verifying the Repo port connectionPowering down the UPS Power management Power Protector softwarePower management Maintenance Important battery safety information Replacing the batteriesBattery care and storage guidelines UPS battery replacement procedureMaintenance Replacing the UPS Disconnect the battery leads Remove the UPS battery bracket Replacing the ERM Updating the UPS firmwareTroubleshooting Alarm troubleshootingAlarm number Alarm name Alarm description Alarm type Battery connection condition General alarm conditionSilencing an audible alarm Bypass is out of rangeInternal UPS fault condition Low battery shutdownsInput voltage is out of range Insufficient warning of low batteriesSite wiring condition UPS does not provide the expected backup timeUPS frequently switches between utility and battery power Repo conditionUPS is in Auto-Bypass mode UPS is on batteryUtility power condition UPS is on bypassSpecifications UPS physical specificationsERM physical specifications UPS input specificationsPower protection specifications Voltage specificationsOutput tolerance specifications Output feature specificationsMinimum battery runtime Battery specificationsAverage battery runtime Environmental specifications Repo port specificationsUPS spare parts list SparesOrdering spares Hardware optionsSafety and regulatory compliance Warranty information Limited warranty$250,000 Computer Load Protection Guarantee Regulatory informationPre-Failure Battery Warranty Recommended duration of useGrounding methods to prevent electrostatic discharge Electrostatic dischargePreventing electrostatic discharge HP contact information Support and other resourcesBefore you contact HP Acronyms and abbreviations Documentation feedback Index Index