Chapter 2 - Software Overview

Data Processing

Measurement Calculator

Use this option to perform arithmetic operations on the measurement registers. For example if you make mea- surements on one antenna and wish to compare the results to another antenna at each point of rotation and each fre- quency. Or if you have a calibrated reference antenna an wish to normalize additional measurements to the max or min value of the reference antenna. Remember all measurement data is linear so you may want to “LOG” the data before doing math. If you select MAX or MIN then all measurement elements will be replaced with MAX or MIN. This creates a normalization reference if you do your math correctly.

Dipole Link Simulator

The Diple Link Simulator is used to create ideal dipole measurements based on a set of physical and environmental factors. These calculated measurements can be imported directly to the measurement calculator for comparison with Measured Data.

Vertical Swing Correction

The Vertical Swing Correction tool is used to compensate for the tilt of the platform when making Vertical / Elevation Measurements.

34

Image 34
Contents Desktop Antenna Measurement System Model Page Table Of Contents Page Page Introduction Features Key FeaturesRequirements Minimum System RequirementsUSB Port Platform Controller Unit Platform Controller rear view Platform Controller top viewParallel Port Platform Controller Unit Control Unit Front View Control Unit Side ViewPage Package Contents Unpacking the SystemTripod and Elevation Unit Assembly Tripod AssemblyVertical Assembly Platform Assembly Connecting the platform and vertical actuatorCable Connections Attaching the cablesSoftware and Hardware Installation Installing the SoftwareOverview Software ConfigurationLPT Parallel Port Driver Installation Instructions StepSpectrum Analyzer Name setting Network Analyzer Name settingSignal Generator Name setting Power MeterTripod Compatibility Information System Test Platform Positioning TestScreen Sleepers and Power Saving options Installation NotesSpecial Installation Notes Other Running ApplicationsPage Chapter Source Instrument Settings Only instrument Measurement SettingsMeasurement Settings Instrument Selection and Settings Receive Instrument -Power Meter SettingsMeasurement Settings Elevation setup Measurement SettingsAzimuth setup Platform Settings and CalibrationCalibration Settings Scalar Calibration Calibration SettingsPower Sensor Calibration Measurement Controls Measurement ControlsMeaurement Status and Displays Measurement Status window Measurement Status and DisplaysGraphical Status Displays Data Processing Data Processing IntroductionData Registers Active RegisterData Processing Dynamic Amplitude Plot Dipole Link Simulator Measurement CalculatorVertical Swing Correction Page System Calibration Performing a Scalar CalibrationMaking a basic Horizontal/Azimuth Measurement Basic MeasurementsMaking a basic Vertical/Elevation Measurement Az/El Scan Measurements Performing an AZ/EL Scan MeasurementPage Data Processing Screenshot IntroductionData Processing Feature To Label a Plot Viewing and working with measurements in 3DTo Print a Plot To Export as BMP Image File- Click File ExportInstructions Viewing and working with the Dynamic Amplitude PlotDynamic Amplitude Plot Screenshot Viewing and working with the Polar Plot display Polar Plot ScreenshotUnderstanding the Register Math Functions Using the Measurement Calculator / Register Math FunctionRegister Math / Calculator Screenshot Math FunctionsLinear LinMag LogMagExporting Data Data Processing FeatureMeasurement Export Process Measurement Export Process Contd Using the Dipole and Isotropic Link Calculator Using the Dipole and Isotropic Link Calculator Contd Group Delay Screenshot Page Page Troubleshooting Operation Troubleshooting and ServiceTroubleshooting Service and Contact Info
Related manuals
Manual 61 pages 62.96 Kb