Chapter 4 - Using the Data Processing Feature

Data Processing Feature

Measurement Export Process

Contd.

Adata is your measurement data array in complex format from the baisc page 1 software

The first column is a scalar array and can set the count for example “frequencies” or angle. You can do this in one of two ways. Enter a known one dimensional array variable such as “NumM”. The program variable “NumM” is a 1-D array otherwise only a single row will be written. The number of elements in the NumM array will set column 1 variable “Scalar” (number of data ROWS). Column1 “Scalar” array is automatically set

from the variable you enter into the window unless you press one of the other two Set Scalar buttons.

Make your own Scalar array. Enter the Start, Stop, NumPts such as

Frequencys in the windows below the Scalar switch. Remember if switch is in the up position Scalar will still be used for the number of rows but not written to the output file.

Notice there is also a SET SCALAR button below column 2. You may choose to set the number of rows using the size of column 2.

This will set Scalar and if Scalar is present in column 1 window and switch 1 isin the down position then the output file will include the row count or whatever.

Any one of the switches in the up position will skip that parameter in the output file. Note that for basic Antenna rotation measurements the frequency is constant while the path loss and angle is the program measurement complex variable “Adata”. I you wanted to create a text

based output file for a spreadsheet which contains the results of a rotation and measurement set then set all switches tothe up position except for switch 2 (or 3 or 4 or 5). Then enter Adata into window 2 below switch 2. Press the Set Scalar button in column 2. Then export the data. The resulting text file will contain two columns. Column 1 = Magnitude and column 2 will contain the position. Open the file with Note Pad and use copy & paste to transfer into spreadsheet. If you wanted column 1 to contain the row count then use Set Scalar in column 1. Enter the number of measurements (n)from page 1 software (in the slider window) and a start stop(n) number. Then export. stop number (1

Notice that there are “From Variable” “From Disc” check boxes below each Complex switch. When From Variable is checked the data is retrieved from the variable in the box below the switch at the time of export.

When From Disc is checked you are prompted for a disc data file name at the time of export. The disc file format is that used by VeePRO complex measurement format ie. (Mag, @Ang) in a single column. This proves

invaluable for a wide variety of vector measurements from VNA’s.

48

Image 48
Contents Desktop Antenna Measurement System Model Page Table Of Contents Page Page Introduction Features Key FeaturesRequirements Minimum System RequirementsUSB Port Platform Controller Unit Platform Controller rear view Platform Controller top viewParallel Port Platform Controller Unit Control Unit Front View Control Unit Side ViewPage Package Contents Unpacking the SystemTripod Assembly Tripod and Elevation Unit AssemblyVertical Assembly Platform Assembly Connecting the platform and vertical actuatorCable Connections Attaching the cablesSoftware and Hardware Installation Installing the SoftwareSoftware Configuration LPT Parallel Port Driver Installation InstructionsOverview StepNetwork Analyzer Name setting Signal Generator Name settingSpectrum Analyzer Name setting Power MeterTripod Compatibility Information System Test Platform Positioning TestInstallation Notes Special Installation NotesScreen Sleepers and Power Saving options Other Running ApplicationsPage Chapter Measurement Settings Measurement Settings Instrument Selection and SettingsSource Instrument Settings Only instrument Receive Instrument -Power Meter SettingsMeasurement Settings Measurement Settings Azimuth setupElevation setup Platform Settings and CalibrationCalibration Settings Calibration Settings Scalar CalibrationPower Sensor Calibration Measurement Controls Measurement ControlsMeasurement Status and Displays Meaurement Status and Displays Measurement Status windowGraphical Status Displays Data Processing Data Processing IntroductionData Registers Active RegisterData Processing Dynamic Amplitude Plot Measurement Calculator Dipole Link SimulatorVertical Swing Correction Page System Calibration Performing a Scalar CalibrationBasic Measurements Making a basic Horizontal/Azimuth MeasurementMaking a basic Vertical/Elevation Measurement Az/El Scan Measurements Performing an AZ/EL Scan MeasurementPage Data Processing Screenshot IntroductionData Processing Feature Viewing and working with measurements in 3D To Print a PlotTo Label a Plot To Export as BMP Image File- Click File ExportViewing and working with the Dynamic Amplitude Plot InstructionsDynamic Amplitude Plot Screenshot Viewing and working with the Polar Plot display Polar Plot ScreenshotUsing the Measurement Calculator / Register Math Function Register Math / Calculator ScreenshotUnderstanding the Register Math Functions Math FunctionsLinear LinMag LogMagData Processing Feature Exporting DataMeasurement Export Process Measurement Export Process Contd Using the Dipole and Isotropic Link Calculator Using the Dipole and Isotropic Link Calculator Contd Group Delay Screenshot Page Page Troubleshooting and Service Troubleshooting OperationTroubleshooting Service and Contact Info