Table 8: Drive Parameters (Continued)

Parameter

Description

 

 

QueueDepth = n

Values from 1–64 (decimal). Default = 64. Requests per

 

LUN/Target (see Queue Target parameter).

 

 

QueueTarget = n

Values 0 or 1 (decimal). Default = 0. 0 = QueueDepth

 

applies on a per LUN basis: 1 = QueueDepth applies on

 

a Target basis.

 

 

RATOV = n

Values are in seconds from 2 to 120. Default = 2. This

 

value is the ELS request time-out.

 

 

ReadCheck = n

Values 0 or 1. Default = 1. 0 = do not enable byte

 

counting for read operations. 1 = enable byte counting. If

 

bytes counted are less than requested transfer count,

 

issue underrun.

 

 

ResetFF = n

Values 0 or 1. Default = 1. 0 = ResetBus translates to LIP

 

(F7). 1 = ResetBus translates to LIP (FF). Used for

 

WolfPack to force reservations to be freed when

 

ResetBus issued. Only meaningful for FC_AL topology

 

and Seagate native FC hard drives.

 

 

ResetTPRLO = n

Values 0 or 1. Default = 1. 0 = ResetBus translates to LIP

 

(). 1 = ResetBus translates to ThirdPartyProcessLogout +

 

LIP (). Used for WolfPack to force reservations to be

 

freed when ResetBus is issued.

 

 

RetryInterval = n

Values are in seconds from 2-255. Default = 45. Used for

 

time-out interval if RetryloTimeOut = 1. Must be shorter

 

than Class driver TimeOutInterval.

 

 

RetryloTimeOut = n

Values 0 or 1. Default = 1. 1 = allows HBA to time-out I/O

 

prior to port driver’s time-out that causes a LIP/Link

 

Reset.

 

 

RTTOV = n

Values are in milliseconds from 100 to 511. Default =

 

256. Represents time-out between phases of Off-line to

 

On-line protocol.

 

 

ScanDown = n

Values 0 or 1. Default = 0. 0 = Lowest AL_PA = Lowest

 

physical disk (ascending AL_PA order). 1 = Highest

 

AL_PA = Lowest Physical Disk (ascending SEL_ID

 

order).

 

 

42

AB232A PCI-X Host Bus Adapter Installation Guide

Image 42
Contents Hp StorageWorks AB232A PCI-X Host Bus Adapter Page Contents Troubleshooting Figures Contents About this Guide Overview Intended AudienceRelated Documentation Text Symbols ConventionsDocument Conventions Equipment Symbols Getting Help HP Technical SupportHP Storage Website HP Authorized ResellerAdapter Features Product Description Illustrates the AB232A HBA Performance Specifications Installation2 Hardware Requirements Recording Reference Numbers Installing the HBA into a Computer Installation Verifying the Installation Amber LED L1 Green LED L2 StateConfiguration Guidelines Installation Installing the Scsi Miniport Driver Device Driver Installation Installing or Upgrading a New DriverSystem Requirements Installing the LightPulse Utility Installing the Scsi Miniport Driver Troubleshooting4 Post Conditions and Results Using The Event Viewer Windows Miniport Event Log Codes Snsrsp RcvseqPT-PT Iostatfcprsperr Iostatintermedrsp Ioerrabortrequested Diagnostic and Configuration Utilities Using LightPulse Utility View HBA ParametersClick Download Modify Diagnostic Driver Parameters in the Windows Registry Modify the Driver ParametersLists the current parameters that you can set Parameter Description Diagnostic and Configuration Utilities Set Up Persistent Binding Prerequisites Global Automap and Unmasking Overview Test Host Bus Adapters Mapping and Masking LUNsRestart Host Bus Adapters MaintenanceModify Test Options Input/OutputShow Host Bus Adapter Info Quit the LightPulse UtilityDiagnostic and Configuration Utilities Regulatory Compliance Notices Federal Communications Commission Notice Class a EquipmentNetwork and Serial Cables IEC EMC Statement WorldwideSpécification ATI Classe a France Canadian Notice Avis Canadien European Union Notice Japanese Notice Harmonics Conformance Japan German Noise DeclarationLaser Safety Certification and Classification InformationElectrostatic Discharge Grounding Methods Index Index