Diagnostic and Configuration Utilities
Persistent binding permanently maps a device to the following:
■Binding type World Wide Port Name (WWPN), World Wide Node Name (WWNN), or a Destination Identifier (D_ID)
■SCSI bus
■SCSI ID
Prerequisites
■Installed Miniport driver with the adjunct driver
■Installed LightPulse Utility
■Global Automap All Targets is enabled. Global Automap All Targets is enabled or disabled from the Global Automap window
Setting Up Persistent Binding
From the LightPulse Utility Main menu screen:
1.Choose the desired HBA.
2.Expand the category list and choose Persistent Binding.
3.Click on a target and click Add. The Add Binding window displays, as shown in Figure 2.
Figure 2: Add Binding window
4.Click the target to be bound from the Unbound Targets list.
5.If required, change the Bind Type for the target.
6.If required, change the SCSI Bus and SCSI ID values.
7.Click OK. The letters PB display next to the target row.
AB232A | 45 |