HP Modular Cooling System manual Battery replacement notice, Taiwan battery recycling notice

Page 79

accordance with US FDA regulations and the IEC 60825-1. The product does not emit hazardous laser radiation.

Each laser product complies with 21 CFR 1040.10 and 1040.11 except for deviations pursuant to Laser Notice No. 50, dated May 27, 2001; and with IEC 60825-1:1993/A2:2001.

WARNING: Use of controls or adjustments or performance of procedures other than those specified herein or in the laser product's installation guide may result in hazardous radiation exposure. To reduce the risk of exposure to hazardous radiation:

Do not try to open the module enclosure. There are no user-serviceable components inside.

Do not operate controls, make adjustments, or perform procedures to the laser device other than those specified herein.

Allow only HP Authorized Service technicians to repair the unit.

The Center for Devices and Radiological Health (CDRH) of the U.S. Food and Drug Administration implemented regulations for laser products on August 2, 1976. These regulations apply to laser products manufactured from August 1, 1976. Compliance is mandatory for products marketed in the United States.

Battery replacement notice

WARNING: The computer contains an internal lithium manganese dioxide, a vanadium pentoxide, or an alkaline battery pack. A risk of fire and burns exists if the battery pack is not properly handled. To reduce the risk of personal injury:

Do not attempt to recharge the battery.

Do not expose the battery to temperatures higher than 60°C (140°F).

Do not disassemble, crush, puncture, short external contacts, or dispose of in fire or water.

Batteries, battery packs, and accumulators should not be disposed of together with the general household waste. To forward them to recycling or proper disposal, use the public collection system or return them to HP, an authorized HP Partner, or their agents.

For more information about battery replacement or proper disposal, contact an authorized reseller or an authorized service provider.

Taiwan battery recycling notice

The Taiwan EPA requires dry battery manufacturing or importing firms in accordance with Article 15 of the Waste Disposal Act to indicate the recovery marks on the batteries used in sales, giveaway or promotion. Contact a qualified Taiwanese recycler for proper battery disposal.

Regulatory compliance notices 79

Image 79
Contents Part Number February 2007 Second Edition HP Modular Cooling System User GuideAudience assumptions Contents Replaceable parts and maintenance and service information Introduction OverviewReference Optimum environment and site requirements Configuration factorsSite preparation MCS kit contents InstallationRequired tools Rack hardware kit contentsInstalling the MCS unit Installation Installation Installation Installation Installation Powering up and configuring the unit Installation Installation Installation Installation Installation Enter 4 Activate Actual Values Return to the Main Menu Network Configuration screenInstallation Installation Configuring the IP address through the web interface Installation Installation Installation Installation Management module overview Management moduleManagement module components Reference Description Logging in through the terminal emulation programWeb interface requirements Accessing the management module through the web interfaceSoftware Browser Logging in through the web interfaceTo add an external alarm relay Connecting an external alarm relayManagement module HP Modular Cooling System Utility overview Serial interfaceOption number Submenu Description Main menuMenu Network Configuration submenu IP Configuration submenu Change Passwords submenu Info Factory Default submenu Configuring HyperTerminalConfiguring Minicom Operator display overview Operator displayOperator display components Indicators Meaning Sensors Sensors Water group sensor Snmp notification Type of message Solution Solution Uneven heat load Indicators Meaning Page Indicators Meaning Has been exceeded or the water flow is less than 2 l/min Indicators Meaning Adjusting the operator display Operator display Automatic Door Release Kit Overview Automatic Door Release KitHP Modular Cooling System frequently asked questions Frequently asked questionsQuestion Answer Port x set out lf=strip HP Modular Cooling System troubleshooting TroubleshootingIssue Resolution MCS specifications SpecificationsSpecification Thermal and air flow performance HP 10642 G2 Rack specificationsEnvironmental specifications Features SpecificationsReplaceable parts Replaceable parts and maintenance and service informationMaintenance and service Air and water heat exchanger maintenanceCooling water composition guidelines Water quality requirements and specificationsAcceptable water quality range CSB Hydrological data Acceptable rangeFrost damage Monitoring the quality of cooling solutionsAdjust the MCS leveling feet so that the unit is level Leveling requirementsCondensation management Customer Self Repair Technical supportBefore you contact HP HP contact informationRéparation par le client CSR Riparazione da parte del cliente Reparaciones del propio cliente Reparo feito pelo cliente Technical support Technical support Technical support Modifications Regulatory compliance noticesRegulatory compliance identification numbers Federal Communications Commission noticeCanadian notice CablesEuropean Union regulatory notice Regulatory compliance notices Taiwan battery recycling notice Battery replacement noticePower cord statement for Japan Acronyms and abbreviations Simple Network Management Protocol Power distribution unitSystems Insight Manager Simple Mail Transfer ProtocolIndex Index
Related manuals
Manual 10 pages 27.17 Kb Manual 93 pages 20.21 Kb Manual 4 pages 15.71 Kb Manual 16 pages 5.24 Kb Manual 83 pages 40.42 Kb Manual 60 pages 37.09 Kb

Modular Cooling System specifications

The HP Modular Cooling System (MCS) is a state-of-the-art solution designed to efficiently manage the heat generated by high-density IT environments. As data centers face the ever-increasing demand for processing power, traditional cooling methods often fall short, leading to inefficiencies and raised energy costs. The HP MCS addresses this issue with a scalable, flexible design that optimizes cooling performance while minimizing energy consumption.

One of the main features of the HP Modular Cooling System is its modular architecture, which allows for easy expansion and customization based on the specific needs of a data center. This scalability means that as a facility grows or changes, the cooling system can be modified without the need for extensive renovations or replacements. The MCS can be installed in various configurations, further enhancing its versatility.

The technology behind the HP MCS includes advanced cooling methods such as direct evaporative cooling and chilled water cooling. Direct evaporative cooling utilizes the principles of evaporative heat exchange to cool air without excessive energy consumption, making it an eco-friendly choice. In contrast, chilled water cooling uses a network of pipes filled with chilled water to remove heat from the server environment efficiently. This combination allows the MCS to adapt to various heat loads and ambient conditions.

Another notable characteristic of the HP Modular Cooling System is its intelligent controls and sensors. These components continually monitor temperature and humidity levels within the data center, automatically adjusting cooling output to maintain optimal conditions. This proactive approach helps to prevent overheating, reduces energy usage, and ensures the longevity of IT equipment.

Energy efficiency is further enhanced through the MCS's integration with HP's monitoring and management software. This software analyzes cooling performance trends, providing actionable insights for facility managers, enabling them to make informed decisions regarding cooling strategies. Additionally, the system is designed with environmentally sustainable practices in mind, aligning with global initiatives to reduce carbon footprints and promote green technology.

The HP Modular Cooling System stands out for its combination of innovative technologies, flexibility, and a commitment to energy efficiency. As data centers continue to evolve, the MCS remains a crucial asset in the pursuit of optimized performance and sustainability, providing a reliable solution to meet the demanding cooling needs of modern IT infrastructure.