York YHJD18 THRU 60 warranty Unit COIL1 HEATING2 Model, MBH COP STD Seer HP Coil only Ratings

Page 15

571209-YTG-C-1012

HEATING CAPACITY - Upflow, Downflow, and Horizontal Furnaces and Coils (Coil Only Ratings)

UNIT

COIL1

 

 

 

HEATING2

 

 

 

MODEL

MODEL

 

47 °F

 

 

17 °F

 

HSPF

 

 

MBH

COP

KW

MBH

COP

KW

STD

 

 

13 SEER HP

COIL ONLY

RATINGS

 

 

 

 

 

FC/MC/PC18

18.0

3.36

1.50

12.7

2.16

1.24

8.20

 

FC/MC/PC24

18.0

3.36

1.45

10.4

2.60

1.17

8.20

YHJD18S41S2

FC/MC/PC30

18.0

3.42

1.54

11.4

2.18

1.53

7.75

 

UC24

18.0

3.42

1.54

11.4

2.20

1.52

7.75

 

UC30

18.0

3.42

1.54

11.4

2.20

1.52

7.75

 

FC/MC/PC32

24.0

3.36

2.09

13.9

2.38

1.71

7.70

YHJD24S41S4

FC/MC/PC35

23.8

3.32

2.10

13.9

2.36

1.73

7.70

FC/MC/PC37

24.0

3.44

2.04

14.1

2.42

1.71

7.70

 

 

FC/MC/PC43

24.0

3.44

2.04

14.1

2.42

1.71

7.70

 

FC/MC/PC32

27.4

3.28

2.45

16.0

2.30

2.04

7.70

YHJD30S41S4

FC/MC/PC35

27.4

3.28

2.45

16.0

2.30

2.04

7.70

FC/MC/PC37

28.0

3.38

2.43

16.1

2.32

2.03

7.70

 

 

FC/MC/PC43

28.0

3.38

2.43

16.1

2.32

2.03

7.70

 

FC/MC/PC37

34.4

3.42

2.95

22.4

2.62

2.51

7.70

YHJD36S41S4

FC/MC/PC43

34.6

3.40

2.98

22.2

2.60

2.50

7.70

FC/MC/PC48

34.8

3.44

2.96

22.6

2.64

2.51

7.70

 

 

UC48

35.0

3.52

2.91

22.4

2.62

2.51

7.70

YHJD42S41S4

FC/MC/PC60

40.5

3.72

3.19

23.0

2.50

2.70

7.70

UC60

40.0

3.68

3.18

22.8

2.48

2.69

7.70

 

 

FC/MC/PC60

46.0

3.58

3.76

27.4

2.76

2.91

7.70

YHJD48S41S4

FC/MC62

46.0

3.54

3.81

27.4

2.76

2.91

7.70

 

UC60

46.0

3.56

3.79

27.4

2.74

2.93

7.70

YHJD60S41S5

FC/MC62

58.0

3.44

5.24

39.5

2.66

4.35

7.80

FC64

58.0

3.36

5.49

40.5

2.76

4.30

7.80

 

1.Rated CFM same as for cooling.

2.Heating MBH based on AHRI standards of 70 °F DB (Dry Bulb) entering indoor air, 72% RH (Relative Humidity) outdoor air with 25 feet of interconnecting piping and no supplemental electric heat operation.

COP equals MBH output divided by (total KW input x 3.412).

HSPF (Heating Seasonal Performance Factor) is the total heating output during a normal annual usage period for heating divided by the total electric power input during the same period.

MA Modular Air Handlers use Coil Only Ratings.

PSC furnaces, such as the TG8S, TGLS, and TG9S, use Coil Only Ratings.

— = Not Applicable.

Johnson Controls Unitary Products

15

Image 15
Contents Technical Guide Model Physical and Electrical DataFootnotes System Charge for Various Matched SystemsSeer HP with AIR Handlers Unit AIR HandlerCooling Model Width MODEL1 Rated NET MBH Seer EER CFM SensFC60C Model Width MODEL1 Seer EER Coil CFM Range Cooling Unit Model Rated NET MBH SEER1 WidthSeer HP Coil Unit Furnace Coil Cooling RatedUnit Model Furnace Width Coil MODEL1 Cooling Rated FC/MC/PC32A FC/MC/PC48C FC/MC/PC48D FC/PC60C 9C,V*D20 24.5 Unit AIR COIL1 HEATING2 Model Handler HspfMBH COP STD Seer HP with AIR Handlers MV16C FC60C MBH COP STD Seer HP Coil only Ratings Unit COIL1 HEATING2 ModelModel Furnace COIL1 HEATING2 MBH COP STDEfficiency Motor FURNACES3 Model Furnace COIL1 HEATING2 Hspf 27.4 16.0 34.0 21.4 LX*C20 40.0 22.4 9X*C20 45.5 27.2 9C*C20 SQI AccessoriesTypical Installation Temperature Condensing IdcfmEntering AIR Furnaces Coils MV12B FC/MC35B FC/MC43B MX12B FC/MC/PC32A MV12B FC/MC35B FC/MC43B MV16C FC/MC35C FC/MC43C MX12B MX16C YTG-C-1012 FC/MC/PC37 FC/MC/PC43 FC/MC/PC48 FC/MC/PC48C AHE48D AHR48D AHV48D FC/MC/PC60 FC/MC62 YTG-C-1012 AHE60D AHR60D AHV60D MV20D FC/MC62D FC64D MX20D Entering Outdoor Unit Indoor CoilMBH COP FC/MC/PC18A 28.3 27.5 1000 1200 On next FC/MC/PC48C FC/MC/PC60 1600 1800 Johnson Controls Unitary Products York Drive Norman, OK