ACCESSORIES

Refer to Price Manual for specific model numbers.

Start Assist Kit (S1-2SA067*) - May be required on 24, 30, 36,

&42 models when a TXV is installed. May also be required on 18 & 60 models in low voltage application. The 48 model has factory installed start assist. See Hard Start Kit Accessory Installation Manual for Hard Start Kit part number for each model.

Blower Time Delay - Available to increase efficiency when installed. Installs on indoor section and maintains blower for approximately one minute after cooling thermostat has been satisfied.

Low Temperature Cutout (S1-2LT06700224) - Prevents heat pump operation below -10 °F ambient temperature.

Compressor Blanket - Designed to further reduce the normal operating sound.

TXV Kits - S1-1TVM series thermal expansion valves precisely meter refrigerant for optimum performance over a wide range of conditions. See System Charge table for TXV part number for each model.

Outdoor Thermostat (S1-2TD06700124) - Provides additional staging of supplemental electric heat.

Thermostats - Compatible thermostat controls are available through accessory sourcing. For optimum performance and installation, refer to the UPGNET “Low Voltage Wiring Diagram” document to select and apply controls.

SOUND POWER LEVEL - TYPICAL OCTAVE BAND SPECTRUM (without tone adjustment)

Size

Test Condition

63

125

250

500

1000

2000

4000

8000

dBA

SQI

 

 

 

 

 

 

 

 

 

 

 

 

18

Cooling Mode

67

71

66

69

65

59

58

55

70

19.2

 

 

 

 

 

 

 

 

 

 

 

Heating Mode

68

70

66

68

67

61

60

57

71

19.2

 

 

 

 

 

 

 

 

 

 

 

 

 

24

Cooling Mode

68

70

67

69

72

65

66

62

75

19.0

 

 

 

 

 

 

 

 

 

 

 

Heating Mode

69

69

63

67

67

64

65

62

72

19.1

 

 

 

 

 

 

 

 

 

 

 

 

 

30

Cooling Mode

73

70

69

71

72

66

69

63

76

19.2

 

 

 

 

 

 

 

 

 

 

 

Heating Mode

71

73

69

71

73

68

65

62

76

19.1

 

 

 

 

 

 

 

 

 

 

 

 

 

36

Cooling Mode

72

73

71

72

73

67

66

63

76

19.0

 

 

 

 

 

 

 

 

 

 

 

Heating Mode

70

72

69

70

71

69

65

64

75

19.2

 

 

 

 

 

 

 

 

 

 

 

 

 

42

Cooling Mode

71

71

73

73

72

67

67

64

77

19.1

 

 

 

 

 

 

 

 

 

 

 

Heating Mode

71

71

71

72

72

69

69

65

77

19.1

 

 

 

 

 

 

 

 

 

 

 

 

 

48

Cooling Mode

72

71

68

69

66

62

57

53

71

19.1

 

 

 

 

 

 

 

 

 

 

 

Heating Mode

71

73

70

72

70

68

65

63

75

19.1

 

 

 

 

 

 

 

 

 

 

 

 

 

60

Cooling Mode

69

69

69

70

70

65

64

63

74

19.2

 

 

 

 

 

 

 

 

 

 

 

Heating Mode

68

69

68

69

71

65

63

62

74

19.0

 

 

 

 

 

 

 

 

 

 

 

 

 

Rated in accordance with ARI Standard 270.

22

Johnson Controls Unitary Products

Image 22
Contents Technical Guide Physical and Electrical Data ModelSystem Charge for Various Matched Systems FootnotesSens Unit AIR HandlerCooling Model Width MODEL1 Rated NET MBH Seer EER CFM Seer HP with AIR HandlersFC60C Unit Furnace Coil Cooling Rated Coil CFM Range Cooling Unit Model Rated NET MBH SEER1 WidthSeer HP Coil Model Width MODEL1 Seer EERUnit Model Furnace Width Coil MODEL1 Cooling Rated FC/MC/PC32A FC/MC/PC48C FC/MC/PC48D FC/PC60C 9C,V*D20 24.5 Hspf Unit AIR COIL1 HEATING2 Model HandlerMBH COP STD Seer HP with AIR Handlers MV16C FC60C Unit COIL1 HEATING2 Model MBH COP STD Seer HP Coil only RatingsMBH COP STD Model Furnace COIL1 HEATING2Efficiency Motor FURNACES3 Model Furnace COIL1 HEATING2 Hspf 27.4 16.0 34.0 21.4 LX*C20 40.0 22.4 9X*C20 45.5 27.2 9C*C20 Accessories SQITypical Installation Condensing Idcfm TemperatureEntering AIR Furnaces Coils MV12B FC/MC35B FC/MC43B MX12B FC/MC/PC32A MV12B FC/MC35B FC/MC43B MV16C FC/MC35C FC/MC43C MX12B MX16C YTG-C-1012 FC/MC/PC37 FC/MC/PC43 FC/MC/PC48 FC/MC/PC48C AHE48D AHR48D AHV48D FC/MC/PC60 FC/MC62 YTG-C-1012 AHE60D AHR60D AHV60D MV20D FC/MC62D FC64D MX20D Outdoor Unit Indoor Coil EnteringMBH COP FC/MC/PC18A 28.3 27.5 1000 1200 On next FC/MC/PC48C FC/MC/PC60 1600 1800 Johnson Controls Unitary Products York Drive Norman, OK