ACCESSORIES
Refer to Price Manual for specific model numbers.
Start Assist Kit (S1-2SA067*) - May be required on 24, 30, 36,
&42 models when a TXV is installed. May also be required on 18 & 60 models in low voltage application. The 48 model has factory installed start assist. See Hard Start Kit Accessory Installation Manual for Hard Start Kit part number for each model.
Blower Time Delay - Available to increase efficiency when installed. Installs on indoor section and maintains blower for approximately one minute after cooling thermostat has been satisfied.
Low Temperature Cutout
Compressor Blanket - Designed to further reduce the normal operating sound.
TXV Kits -
Outdoor Thermostat
Thermostats - Compatible thermostat controls are available through accessory sourcing. For optimum performance and installation, refer to the UPGNET “Low Voltage Wiring Diagram” document to select and apply controls.
SOUND POWER LEVEL - TYPICAL OCTAVE BAND SPECTRUM (without tone adjustment)
Size | Test Condition | 63 | 125 | 250 | 500 | 1000 | 2000 | 4000 | 8000 | dBA | SQI | |
|
|
|
|
|
|
|
|
|
|
|
| |
18 | Cooling Mode | 67 | 71 | 66 | 69 | 65 | 59 | 58 | 55 | 70 | 19.2 | |
|
|
|
|
|
|
|
|
|
|
| ||
Heating Mode | 68 | 70 | 66 | 68 | 67 | 61 | 60 | 57 | 71 | 19.2 | ||
| ||||||||||||
|
|
|
|
|
|
|
|
|
|
|
| |
24 | Cooling Mode | 68 | 70 | 67 | 69 | 72 | 65 | 66 | 62 | 75 | 19.0 | |
|
|
|
|
|
|
|
|
|
|
| ||
Heating Mode | 69 | 69 | 63 | 67 | 67 | 64 | 65 | 62 | 72 | 19.1 | ||
| ||||||||||||
|
|
|
|
|
|
|
|
|
|
|
| |
30 | Cooling Mode | 73 | 70 | 69 | 71 | 72 | 66 | 69 | 63 | 76 | 19.2 | |
|
|
|
|
|
|
|
|
|
|
| ||
Heating Mode | 71 | 73 | 69 | 71 | 73 | 68 | 65 | 62 | 76 | 19.1 | ||
| ||||||||||||
|
|
|
|
|
|
|
|
|
|
|
| |
36 | Cooling Mode | 72 | 73 | 71 | 72 | 73 | 67 | 66 | 63 | 76 | 19.0 | |
|
|
|
|
|
|
|
|
|
|
| ||
Heating Mode | 70 | 72 | 69 | 70 | 71 | 69 | 65 | 64 | 75 | 19.2 | ||
| ||||||||||||
|
|
|
|
|
|
|
|
|
|
|
| |
42 | Cooling Mode | 71 | 71 | 73 | 73 | 72 | 67 | 67 | 64 | 77 | 19.1 | |
|
|
|
|
|
|
|
|
|
|
| ||
Heating Mode | 71 | 71 | 71 | 72 | 72 | 69 | 69 | 65 | 77 | 19.1 | ||
| ||||||||||||
|
|
|
|
|
|
|
|
|
|
|
| |
48 | Cooling Mode | 72 | 71 | 68 | 69 | 66 | 62 | 57 | 53 | 71 | 19.1 | |
|
|
|
|
|
|
|
|
|
|
| ||
Heating Mode | 71 | 73 | 70 | 72 | 70 | 68 | 65 | 63 | 75 | 19.1 | ||
| ||||||||||||
|
|
|
|
|
|
|
|
|
|
|
| |
60 | Cooling Mode | 69 | 69 | 69 | 70 | 70 | 65 | 64 | 63 | 74 | 19.2 | |
|
|
|
|
|
|
|
|
|
|
| ||
Heating Mode | 68 | 69 | 68 | 69 | 71 | 65 | 63 | 62 | 74 | 19.0 | ||
| ||||||||||||
|
|
|
|
|
|
|
|
|
|
|
|
Rated in accordance with ARI Standard 270.
22 | Johnson Controls Unitary Products |