HEATING PERFORMANCE DATA
CONDENSING UNIT MODEL NO | YHJD60S41S5 |
|
|
|
|
|
|
| ||
EVAPORATOR COIL MODEL NO | FC/MC62 |
|
|
|
|
|
|
|
| |
AIR TEMP. | AIR TEMP. |
|
|
|
| ID CFM |
|
|
|
|
ENTERING | ENTERING |
| 1600 |
|
| 1800 |
|
| 2000 |
|
OUTDOOR UNIT | INDOOR COIL |
|
|
|
|
|
|
|
|
|
MBH | COP | KW | MBH | COP | KW | MBH | COP | KW | ||
|
|
|
|
|
|
|
|
|
|
|
| 60 | 72.1 | 3.8 | 5.62 | 71.1 | 3.8 | 5.53 | 70.1 | 3.8 | 5.42 |
60 |
|
|
|
|
|
|
|
|
|
|
70 | 70.9 | 3.4 | 6.11 | 70.6 | 3.4 | 6.02 | 70.3 | 3.5 | 5.90 | |
|
|
|
|
|
|
|
|
|
|
|
| 80 | 69.8 | 3.1 | 6.62 | 70.2 | 3.2 | 6.50 | 70.5 | 3.2 | 6.40 |
|
|
|
|
|
|
|
|
|
|
|
| 60 | 62.7 | 3.7 | 4.99 | 62.4 | 3.7 | 4.95 | 62.1 | 3.7 | 4.90 |
47 |
|
|
|
|
|
|
|
|
|
|
70 | 61.1 | 3.3 | 5.43 | 61.1 | 3.5 | 5.09 | 61.1 | 3.8 | 4.76 | |
|
|
|
|
|
|
|
|
|
|
|
| 80 | 59.6 | 3.0 | 5.86 | 59.9 | 3.4 | 5.23 | 60.1 | 3.8 | 4.61 |
|
|
|
|
|
|
|
|
|
|
|
| 60 | 55.6 | 3.5 | 4.63 | 55.9 | 3.6 | 4.62 | 56.2 | 3.6 | 4.60 |
40 |
|
|
|
|
|
|
|
|
|
|
70 | 54.3 | 3.1 | 5.06 | 54.5 | 3.2 | 5.04 | 54.8 | 3.2 | 5.00 | |
|
|
|
|
|
|
|
|
|
|
|
| 80 | 52.9 | 2.8 | 5.50 | 53.1 | 2.9 | 5.46 | 53.3 | 2.9 | 5.40 |
|
|
|
|
|
|
|
|
|
|
|
| 60 | 45.3 | 3.2 | 4.20 | 45.7 | 3.2 | 4.20 | 46.1 | 3.2 | 4.21 |
30 |
|
|
|
|
|
|
|
|
|
|
70 | 43.9 | 2.9 | 4.51 | 44.3 | 2.9 | 4.53 | 44.8 | 2.9 | 4.54 | |
|
|
|
|
|
|
|
|
|
|
|
| 80 | 42.4 | 2.6 | 4.82 | 43.0 | 2.6 | 4.86 | 43.5 | 2.6 | 4.90 |
|
|
|
|
|
|
|
|
|
|
|
| 60 | 38.0 | 2.8 | 3.93 | 38.5 | 2.9 | 3.96 | 39.1 | 2.9 | 4.00 |
17 |
|
|
|
|
|
|
|
|
|
|
70 | 35.5 | 2.5 | 4.19 | 36.5 | 2.5 | 4.24 | 37.5 | 2.6 | 4.31 | |
|
|
|
|
|
|
|
|
|
|
|
| 80 | 33.0 | 2.2 | 4.47 | 34.4 | 2.2 | 4.53 | 35.9 | 2.3 | 4.61 |
|
|
|
|
|
|
|
|
|
|
|
| 60 | 32.3 | 2.6 | 3.71 | 32.8 | 2.6 | 3.74 | 33.3 | 2.6 | 3.75 |
10 |
|
|
|
|
|
|
|
|
|
|
70 | 31.3 | 2.3 | 4.04 | 31.5 | 2.3 | 4.05 | 31.8 | 2.3 | 4.08 | |
|
|
|
|
|
|
|
|
|
|
|
| 80 | 30.3 | 2.0 | 4.35 | 30.2 | 2.0 | 4.36 | 30.2 | 2.0 | 4.38 |
NOTE: ALL CAPACITIES ARE NET, WITH INDOOR FAN HEAT ALREADY DEDUCTED. KW VALUES ARE FOR THE SYSTEM (OUTDOOR + INDOOR).
Multipliers for determining the performance with other indoor sections.
Air Handlers | Coils | MBH | COP | KW |
– | FC/MC62 | 1.00 | 1.00 | 1.00 |
– | FC64 | 1.03 | 0.95 | 1.08 |
AHE60D | – | 0.99 | 1.01 | 0.98 |
AHR60D | – | 1.01 | 0.98 | 1.04 |
AHV60D | – | 0.99 | 0.97 | 1.02 |
MV20D | FC/MC62D | 1.00 | 1.00 | 1.00 |
MV20D | FC64D | 1.01 | 0.97 | 1.05 |
MX20D | FC/MC62D | 0.99 | 1.02 | 0.97 |
MX20D | FC64D | 1.00 | 0.98 | 1.02 |
Furnaces | Coils | MBH | COP | KW |
T*(8,L)V*C20 | FC/MC62D | 0.99 | 0.96 | 1.03 |
T*(8,L)V*C20 | FC64D | 1.01 | 0.95 | 1.06 |
T*(8,L)X*C20 | FC/MC62D | 0.98 | 0.98 | 1.00 |
T*(8,L)X*C20 | FC64D | 1.00 | 0.95 | 1.05 |
T*9(C,V)*C20 | FC64D | 1.01 | 0.94 | 1.07 |
T*9(C,V)*D20 | FC/MC62D | 0.99 | 0.96 | 1.03 |
T*9(C,V)*D20 | FC64D | 1.01 | 0.94 | 1.07 |
T*9X*C20 | FC/MC62D | 0.98 | 0.98 | 1.00 |
T*9X*C20 | FC64D | 1.01 | 0.94 | 1.07 |
T*9X*D20 | FC/MC62D | 0.98 | 0.97 | 1.01 |
T*9X*D20 | FC64D | 1.01 | 0.95 | 1.05 |
Y*(8,L)C*C20 | FC/MC62D | 0.99 | 0.96 | 1.03 |
Y*(8,L)C*C20 | FC64D | 1.01 | 0.95 | 1.06 |
Y*9C*C20 | FC/MC62D | 0.99 | 0.95 | 1.04 |
Y*9C*C20 | FC/MC62D | 0.99 | 0.95 | 1.04 |
Y*9C*C20 | FC64D | 1.01 | 0.94 | 1.08 |
Y*9C*D20 | FC/MC62D | 0.99 | 0.96 | 1.03 |
Y*9C*D20 | FC64D | 1.01 | 0.94 | 1.07 |
Subject to change without notice. Published in U.S.A. | |