York YHJD18 THRU 60 Coil CFM Range Cooling Unit Model Rated NET MBH SEER1 Width, Seer HP Coil

Page 6

571209-YTG-C-1012

COOLING CAPACITY - Upflow, Downflow & Horizontal Furnaces and Coils (Coil Only Ratings)

 

COIL

 

 

CFM RANGE

 

 

 

COOLING

 

 

UNIT MODEL

 

 

 

RATED

 

NET MBH

SEER1

 

MODEL

WIDTH

 

(Min.-max.)

 

EER

 

 

CFM

 

 

 

 

 

 

TOTAL

SENS.

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

13 SEER HP COIL

ONLY RATINGS

 

 

 

 

 

 

FC/MC/PC18

14.5,17.5

 

450

- 750

600

 

18.0

14.0

13.00

11.00

 

FC/MC/PC24

14.5,17.5

 

450

- 750

600

 

18.0

14.0

13.50

11.00

YHJD18S41S2

FC/MC/PC30

14.5,17.5

 

450

- 750

600

 

18.0

13.7

13.00

11.00

 

UC24

14.5,17.5

 

450

- 750

600

 

18.0

13.8

13.05

11.00

 

UC30

14.5,17.5

 

450

- 750

600

 

18.0

13.8

13.05

11.00

 

FC/MC/PC32

14.5

 

600 - 1000

800

 

23.8

17.1

13.00

11.00

YHJD24S41S4

FC/MC/PC35

17.5,21.0

 

600 - 1000

800

 

23.6

17.1

13.00

11.00

FC/MC/PC37

14.5

 

600 - 1000

800

 

24.0

17.3

13.00

11.00

 

 

 

 

FC/MC/PC43

17.5,21.0

 

600 - 1000

800

 

24.0

17.3

13.00

11.00

 

FC/MC/PC32

14.5

 

800 - 1200

1000

 

29.8

21.8

13.00

11.00

YHJD30S41S4

FC/MC/PC35

17.5,21.0

 

800 - 1200

1000

 

29.8

21.8

13.00

11.00

FC/MC/PC37

14.5

 

800 - 1200

1000

 

30.0

22.2

13.00

11.00

 

 

 

 

FC/MC/PC43

17.5,21.0

 

800 - 1200

1000

 

30.0

22.2

13.00

11.00

 

FC/MC/PC37

14.5

 

1000

- 1400

1200

 

36.0

26.8

13.00

11.00

YHJD36S41S4

FC/MC/PC43

17.5,21.0

 

1000

- 1400

1200

 

36.0

26.6

13.00

11.00

FC/MC/PC48

21.0,24.5

 

1000

- 1400

1200

 

36.0

26.6

13.00

11.00

 

 

 

 

UC48

21.0,24.5

 

1000

- 1400

1200

 

36.0

26.8

13.00

11.00

YHJD42S41S4

FC/MC/PC60

21.0,24.5

 

1200

- 1600

1400

 

41.0

31.8

13.00

11.00

UC60

21.0,24.5

 

1200

- 1600

1400

 

40.5

31.0

13.00

11.00

 

 

 

 

FC/MC/PC60

21.0,24.5

 

1400

- 1800

1600

 

44.0

33.4

13.00

11.00

YHJD48S41S4

FC/MC62

24.5

 

1400

- 1800

1600

 

44.5

33.8

13.00

11.00

 

UC60

21.0,24.5

 

1400

- 1800

1600

 

44.0

32.8

13.00

11.00

YHJD60S41S5

FC/MC62

24.5

 

1600

- 2000

1800

 

57.5

41.0

13.25

11.35

FC64

24.5

 

1600

- 2000

1800

 

56.5

42.5

13.00

11.00

 

 

 

1.Requires a S1-2FD06700224 Blower Time Delay unless a standard furnace is equipped with one.

MA Modular Air Handlers use Coil Only Ratings.

PSC furnaces, such as the TG8S, TGLS, and TG9S, use Coil Only Ratings.

COOLING CAPACITY - With High Efficiency Motor Furnaces

UNIT

FURNACE

COIL

 

 

COOLING

 

 

 

 

 

RATED

Net MBH

 

 

MODEL

MODEL

 

WIDTH

MODEL1

SEER

EER

 

CFM

TOTAL

SENS.

 

 

 

 

 

 

 

 

 

13 SEER HP WITH HIGH EFFICIENCY MOTOR FURNACES2

 

 

 

 

T*(8,L)V*A12

14.5

FC/MC/PC18A

620

18.0

12.3

14.50

12.30

 

 

 

 

 

 

 

 

 

 

T*(8,L)V*A12

14.5

FC/MC/PC24A

640

18.0

12.7

14.80

12.50

 

 

 

 

 

 

 

 

 

 

T*(8,L)V*A12

14.5

FC/MC/PC30A

640

18.0

12.7

14.80

12.50

 

 

 

 

 

 

 

 

 

 

T*(8,L)V*A12

14.5

UC18A

620

18.0

12.4

14.60

12.30

 

 

 

 

 

 

 

 

 

 

T*(8,L)V*A12

14.5

UC24A

640

18.0

12.8

14.80

12.50

 

 

 

 

 

 

 

 

 

 

T*(8,L)V*A12

14.5

UC30A

640

18.0

12.8

14.80

12.50

 

 

 

 

 

 

 

 

 

 

T*(8,L)V*B12

14.5

FC/MC/PC18A

620

18.0

12.3

14.50

12.30

 

 

 

 

 

 

 

 

 

YHJD18S41S2

T*(8,L)V*B12

17.5

FC/MC/PC24B

575

18.0

12.2

14.90

12.60

 

 

 

 

 

 

 

 

 

T*(8,L)V*B12

17.5

FC/MC/PC30B

575

18.0

12.2

14.90

12.60

 

 

 

 

 

 

 

 

 

 

 

T*(8,L)V*B12

17.5

UC18B

580

18.0

12.0

14.60

12.30

 

 

 

 

 

 

 

 

 

 

T*(8,L)V*B12

17.5

UC24B

575

18.0

12.3

14.90

12.60

 

 

 

 

 

 

 

 

 

 

T*(8,L)V*B12

17.5

UC30B

575

18.0

12.3

15.00

12.60

 

 

 

 

 

 

 

 

 

 

T*(8,L)X*A12

14.5

FC/MC/PC18A

540

18.0

14.3

14.00

12.00

 

 

 

 

 

 

 

 

 

 

T*(8,L)X*A12

14.5

FC/MC/PC24A

595

18.0

14.9

14.00

12.00

 

 

 

 

 

 

 

 

 

 

T*(8,L)X*A12

14.5

FC/MC/PC30A

595

18.0

14.9

14.00

12.00

 

 

 

 

 

 

 

 

 

 

T*(8,L)X*A12

14.5

UC18B

590

18.0

13.9

14.50

12.00

For Notes See Page 12.

6

Johnson Controls Unitary Products

Image 6
Contents Technical Guide Physical and Electrical Data ModelSystem Charge for Various Matched Systems FootnotesSens Unit AIR HandlerCooling Model Width MODEL1 Rated NET MBH Seer EER CFM Seer HP with AIR HandlersFC60C Unit Furnace Coil Cooling Rated Coil CFM Range Cooling Unit Model Rated NET MBH SEER1 WidthSeer HP Coil Model Width MODEL1 Seer EERUnit Model Furnace Width Coil MODEL1 Cooling Rated FC/MC/PC32A FC/MC/PC48C FC/MC/PC48D FC/PC60C 9C,V*D20 24.5 Unit AIR COIL1 HEATING2 Model Handler HspfMBH COP STD Seer HP with AIR Handlers MV16C FC60C Unit COIL1 HEATING2 Model MBH COP STD Seer HP Coil only RatingsModel Furnace COIL1 HEATING2 MBH COP STDEfficiency Motor FURNACES3 Model Furnace COIL1 HEATING2 Hspf 27.4 16.0 34.0 21.4 LX*C20 40.0 22.4 9X*C20 45.5 27.2 9C*C20 Accessories SQITypical Installation Temperature Condensing IdcfmEntering AIR Furnaces Coils MV12B FC/MC35B FC/MC43B MX12B FC/MC/PC32A MV12B FC/MC35B FC/MC43B MV16C FC/MC35C FC/MC43C MX12B MX16C YTG-C-1012 FC/MC/PC37 FC/MC/PC43 FC/MC/PC48 FC/MC/PC48C AHE48D AHR48D AHV48D FC/MC/PC60 FC/MC62 YTG-C-1012 AHE60D AHR60D AHV60D MV20D FC/MC62D FC64D MX20D Entering Outdoor Unit Indoor CoilMBH COP FC/MC/PC18A 28.3 27.5 1000 1200 On next FC/MC/PC48C FC/MC/PC60 1600 1800 Johnson Controls Unitary Products York Drive Norman, OK
Related manuals
Manual 30 pages 24.1 Kb