York YHJF18 THRU 60 warranty Warranty, Description, Features

Page 1

TECHNICAL GUIDE

SPLIT-SYSTEM

HEAT PUMPS

14.5 SEER – R-410A

MODELS: YHJF18 THRU 60

(1.5 THRU 5 NOMINAL TONS, 1

PHASE)

LISTED

Due to continuous product improvement, specifications are subject to change without notice.

Visit us on the web at www.york.com Additional rating information can be found at

www.ahridirectory.org

WARRANTY

Standard 5-year limited parts warranty. 10-year limited compressor warranty.

Extended 10-year limited parts warranty when product is registered online within 90 days of purchase for replace- ment or closing for new home construction.

510667-YTG-B-0509

DESCRIPTION

The 14.5 SEER Series unit is the outdoor part of a versatile cli- mate system. It is designed with a matching indoor coil compo- nent from Johnson Controls Unitary Products. Available for typical applications this climate system is supported with acces- sories and documents to serve specific functions.

FEATURES

Quality Condenser Coils - The coil is constructed of copper tubing and enhanced aluminum fins for increased efficiency and corrosion protection.

Protected Compressor - The complete scroll compressor line is internally protected against high pressure, tempera- ture, and externally by a factory installed high pressure switch. This is accomplished by the simultaneous operation of high pressure relief valve and a temperature sensor which protects the compressor if undesirable operating conditions occur. A liquid line filter-drier further protects the compressor.

Durable Finish - The cabinet is made of pre-painted steel. The pre-treated galvanized steel provides a better paint to steel bond, which resists corrosion and rust creep. Special primer formulas and matted-textured finish insure less fading when exposed to sunlight.

Lower Installed Cost - Installation time and costs are reduced by easy power and control wiring connections. Available in sweat connect models only. The unit contains enough refrigerant for matching indoor coils and 15 feet of interconnecting piping. The small base dimension means less space is required on the ground or roof.

Top Discharge - The warm air from the top mounted fan is blown up away from the structure and any landscaping. This allows compact location on multi-unit applications.

Swept Fan Blade Sound Jacket - The upward air flow car- ries the normal operating noise away from the living area. The rigid top panel effectively isolates any motor sound. Iso- lator mounted compressor and the rippled fins of the con- denser coil muffle the normal fan motor and compressor operating sounds. The swept wing fan blade and compressor sound jacket futher reduce noise levels.

Low Maintenance - Long life permanently lubricated motor- bearings need no annual servicing.

Easy Service Access - Fully exposed refrigerant connec- tions, and a single panel covering the electrical controls make for easy servicing of the unit.

Secured Service Valves - Secured re-usable service valves are provided on both the liquid and vapor sweat connections for ease of evacuating and charging.

U.L. and C.U.L. listed - approved for outdoor application.

Agency Listed - U.L. and C.U.L. listed - approved for out- door application. The unit is certified in accordance with the Unitary Small Equipment cerification program, which is based on ARI Standard 210/240.

FOR DISTRIBUTION USE ONLY - NOT TO BE USED AT POINT OF RETAIL SALE

Image 1
Contents Features WarrantyDescription Model Physical and Electrical DataSystem Charge for Various Matched Systems ProceduresFootnotes Sens Cooling Capacity With Air Handler CoilsMV Variable Speed SpeedUnit Model Furnace Coil MODEL1 Stage Cooling Rated Cooling Capacity With High Efficiency Motor FurnacesCooling Model MODEL1 Stage Rated Unit FurnaceSeer EER CFM Heating Capacity With Air Handler Coils Heating Performance With Air HandlerModel Furnace COIL1 ARI HEATING2 Hspf Heating Capacity With High Efficiency Motor FurnacesWith Variable Speed FURNACES3 Model Furnace COIL1 ARI HEATING2 Seer HP with Variable Speed FURNACES3 AccessoriesTypical Field Wiring Typical InstallationSQI Cooling Performance Data TemperatureCondensing Entering AIRID WB F 21.7 MV12B FC/MC43B MV16C FC/MC43C ID WB F 34.5 MV20D FC/MC62D Condensing Unit Model NO. YHJF48S41S1 Indoor Coil Model no MV20D FC/MC62D Cooling Performance Data LOW CFM 1-STAGE OperationHigh CFM Cooling Performance Data High CFM 2-STAGE OperationEntering Heating Performance DataOutdoor Unit Indoor Coil MBH COPYTG-B-0509 27.4 1200 1400 1600 1600 1800 MBH COP MV20D FC/MC62D