HEATING CAPACITY - With High Efficiency Motor Furnaces
UNIT
MODEL
VARIABLE SPEED FURNACE MODEL
COIL
MODEL1
|
| HEATING2 |
|
| ||
|
|
|
| |||
STAGE | RATED | NET MBH | HSPF | COP @ 47 | ||
CFM | 47 OD | 17 OD | ||||
|
|
| ||||
|
|
|
|
|
|
14.5 SEER HP WITH VARIABLE SPEED FURNACES3
YHJF60S41S1
|
| 1 | 835 | 42.0 | – | – | 2.98 |
T*(8,L)X*C20 | FC/MC62D | 2 | 1665 | 57.0 | 39.5 | 9.00 | 3.64 |
|
|
|
|
|
|
|
|
|
| 2 | 835 | 56.5 | 38.5 | 8.85 | 2.62 |
|
|
|
|
|
|
|
|
|
| 1 | 1220 | 43.5 | – | – | 3.38 |
T*9X*C20 | FC/MC62D |
|
|
|
|
|
|
2 | 1595 | 57.0 | 40.0 | 9.00 | 3.58 | ||
|
|
|
|
|
|
|
|
|
| 2 | 1220 | 55.6 | 39.0 | 8.60 | 3.08 |
|
|
|
|
|
|
|
|
|
| 1 | 1240 | 43.5 | – | – | 3.42 |
T*9X*D20 | FC/MC62D |
|
|
|
|
|
|
2 | 1645 | 57.0 | 40.0 | 9.00 | 3.60 | ||
|
|
|
|
|
|
|
|
|
| 2 | 1240 | 55.6 | 39.0 | 8.65 | 3.10 |
|
|
|
|
|
|
|
|
|
| 1 | 1015 | 42.5 | – | – | 3.20 |
Y*(8,L)C*C20 | FC/MC62D |
|
|
|
|
|
|
2 | 1615 | 57.0 | 40.0 | 9.00 | 3.58 | ||
|
|
|
|
|
|
|
|
|
| 2 | 1015 | 55.6 | 39.0 | 8.75 | 2.86 |
|
|
|
|
|
|
|
|
|
| 1 | 1040 | 43.0 | – | – | 3.20 |
(Y*9C/T*9V)*C20 | FC/MC62D |
|
|
|
|
|
|
2 | 1655 | 57.0 | 40.5 | 9.00 | 3.54 | ||
|
|
|
|
|
|
|
|
|
| 2 | 1040 | 54.9 | 39.0 | 8.70 | 2.88 |
|
|
|
|
|
|
|
|
|
| 1 | 1085 | 43.0 | – | – | 3.26 |
(Y*9C/T*9V)*D20 | FC/MC62D |
|
|
|
|
|
|
2 | 1630 | 57.0 | 40.0 | 9.00 | 3.54 | ||
|
|
|
|
|
|
|
|
|
| 2 | 1085 | 55.6 | 39.0 | 8.65 | 2.94 |
|
|
|
|
|
|
|
|
1.MC coils available with a factory installed horizontal drain pan. See price pages for specific model number.
2.Heating MBH based on ARI standards of 70° DB entering indoor air, 72% RH outdoor air with 25 feet of interconnecting piping and no supplemental electric heat operation.
3.Variable speed furnaces have B.O.D (Blower on Delay) standard.
CP equals MBH output divided by (total KW input x 3.412).
HSPF (Heating Seasonal Performance Factor) is the total heating output during a normal annual usage period for heating divided by the total electric power input during the same period.
— = Not Applicable.
ACCESSORIES
Refer to Price Manual for specific model numbers.
Start Assist Kit - Provides starting torque for low voltage appli- cations.
Blower Time Delay - Available to increase efficiency when installed. Installs on indoor section and maintains blower for approximately one minute after cooling thermostat has been satisfied.
Low Temperature Cutout (2LT06700224) - Prevents heat pump operation below
Thermal Expansion Valve Kit - 1TVM4 Series TXV kit used
when required.
Outdoor Thermostat (2TD06700124) - Provides additional staging of supplemental electric heat.
Thermostats - Compatible thermostat controls are available through accessory sourcing. For optimum performance and installation, refer to the UPGNET “Low Voltage Wiring Diagram” document to select and apply controls.
10 | Johnson Controls Unitary Products |