York YHJF18 THRU 60 warranty Unit Furnace, Cooling Model MODEL1 Stage Rated, Seer EER CFM

Page 6

510667-YTG-B-0509

COOLING CAPACITY - With High Efficiency Motor Furnaces (Continued)

UNIT

FURNACE

COIL

 

 

 

 

COOLING

 

 

MODEL

MODEL

MODEL1

W

STAGE

RATED

Net MBH

SEER

EER

 

 

CFM

TOTAL

SENS.

 

 

 

 

 

 

 

 

 

14.5 SEER HP WITH VARIABLE SPEED FURNACES2

 

 

 

 

T*(8,L)X*A12

FC/MC/PC37A

14

1290

35.8

27.4

14.50

12.00

 

T*(8,L)X*B12

FC/MC/PC43B

17

1300

35.8

27.4

14.50

12.00

 

T*(8,L)X*C16

FC/MC/PC43C

21

1175

35.4

26.4

15.00

12.50

 

T*(8,L)X*C20

FC/MC/PC43C

21

1250

36.0

27.4

15.00

12.50

 

T*9X*B12

FC/MC/PC43B

17

1270

35.8

27.4

14.50

12.00

YHJF36S41S1

T*9X*C16

FC/MC/PC43C

21

1260

36.0

27.4

14.50

12.00

 

T*9X*C20

FC/MC/PC43C

21

1185

35.2

26.4

14.50

12.00

 

Y*(8,L)C*C16

FC/MC/PC43C

21

1205

35.2

26.4

14.50

12.00

 

Y*(8,L)C*C20

FC/MC/PC43C

21

1190

35.2

26.4

14.50

12.00

 

(Y*9C/T*9V)*C16

FC/MC/PC43C

21

1240

35.6

27.2

14.20

12.00

 

(Y*9C/T*9V)*C20

FC/MC/PC43C

21

1200

35.2

26.4

14.35

12.00

 

T*(8,L)X*C16

FC/MC62D

21

1360

40.5

31.0

15.00

12.50

 

T*(8,L)X*C20

FC/MC62D

21

1485

40.5

31.8

15.00

12.50

 

T*9X*C16

FC/MC62D

21

1460

40.0

30.8

14.50

12.00

 

T*9X*C20

FC/MC62D

21

1460

40.5

31.0

14.50

12.00

YHJF42S41S1

T*9X*D20

FC/MC62D

24

1425

40.5

31.0

14.50

12.00

 

Y*(8,L)C*C16

FC/MC62D

21

1420

40.0

30.8

14.40

12.00

 

Y*(8,L)C*C20

FC/MC62D

21

1410

40.5

30.8

14.50

12.00

 

(Y*9C/T*9V)*C20

FC/MC62D

21

1445

40.0

30.6

14.05

11.90

 

(Y*9C/T*9V)*D20

FC/MC62D

24

1455

40.0

30.6

14.25

12.00

 

T*(8,L)X*C16

FC/MC62D

21

1610

48.0

36.2

14.50

12.00

 

T*(8,L)X*C20

FC/MC62D

21

1665

48.0

36.2

14.50

12.00

 

 

 

 

 

 

 

 

 

 

 

T*9X*C16

FC/MC62D

21

1550

48.0

36.0

14.50

12.00

 

 

 

 

 

 

 

 

 

 

 

T*9X*C20

FC/MC62D

21

1595

48.0

36.2

14.50

12.00

 

 

 

 

 

 

 

 

 

 

YHJF48S41S1

T*9X*D20

FC/MC62D

24

1610

48.0

36.0

14.50

12.00

 

 

 

 

 

 

 

 

 

Y*(8,L)C*C16

FC/MC62D

21

1635

48.0

36.0

14.50

12.00

 

 

 

 

 

 

 

 

 

 

 

 

Y*(8,L)C*C20

FC/MC62D

21

1615

48.0

36.0

14.50

12.00

 

 

 

 

 

 

 

 

 

 

 

(Y*9C/T*9V)*C16

FC/MC62D

21

1590

47.5

36.0

14.35

12.00

 

 

 

 

 

 

 

 

 

 

 

(Y*9C/T*9V)*C20

FC/MC62D

21

1655

47.5

35.8

14.05

12.00

 

 

 

 

 

 

 

 

 

 

 

(Y*9C/T*9V)*D20

FC/MC62D

24

1630

47.5

35.8

14.25

12.00

 

T*(8,L)X*C20

FC/MC62D

21

1

835

44.0

27.0

14.50

12.00

 

2

1665

57.0

39.5

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

T*9X*C20

FC/MC62D

21

1

1220

48.5

31.6

14.50

12.00

 

 

 

 

 

 

2

1595

56.5

38.5

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

T*9X*D20

FC/MC62D

24

1

1240

48.5

31.8

14.50

12.00

 

 

 

 

 

YHJF60S41S1

2

1645

56.5

39.0

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Y*(8,L)C*C20

FC/MC62D

21

1

1015

46.0

29.2

14.50

12.00

 

 

 

 

 

 

 

2

1615

56.5

38.5

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

(Y*9C/T*9V)*C20

FC/MC62D

21

1

1040

46.5

29.4

14.50

12.00

 

 

 

 

 

 

2

1655

56.0

38.5

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

(Y*9C/T*9V)*D20

FC/MC62D

24

1

1085

47.0

29.8

14.50

12.00

 

 

 

 

 

 

2

1630

56.0

38.5

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

1.MC coils available with a factory installed horizontal drain pan. See price pages for specific model number.

2.Variable speed furnaces have B.O.D (Blower on Delay) standard.

6

Johnson Controls Unitary Products

Image 6
Contents Warranty FeaturesDescription Physical and Electrical Data ModelProcedures System Charge for Various Matched SystemsFootnotes MV Variable Speed Cooling Capacity With Air Handler CoilsSens SpeedCooling Capacity With High Efficiency Motor Furnaces Unit Model Furnace Coil MODEL1 Stage Cooling RatedUnit Furnace Cooling Model MODEL1 Stage RatedSeer EER CFM Heating Performance With Air Handler Heating Capacity With Air Handler CoilsHeating Capacity With High Efficiency Motor Furnaces Model Furnace COIL1 ARI HEATING2 HspfWith Variable Speed FURNACES3 Model Furnace COIL1 ARI HEATING2 Accessories Seer HP with Variable Speed FURNACES3Typical Installation Typical Field WiringSQI Condensing TemperatureCooling Performance Data Entering AIRID WB F 21.7 MV12B FC/MC43B MV16C FC/MC43C ID WB F 34.5 MV20D FC/MC62D Condensing Unit Model NO. YHJF48S41S1 Indoor Coil Model no Cooling Performance Data LOW CFM 1-STAGE Operation MV20D FC/MC62DCooling Performance Data High CFM 2-STAGE Operation High CFMOutdoor Unit Indoor Coil Heating Performance DataEntering MBH COPYTG-B-0509 27.4 1200 1400 1600 1600 1800 MBH COP MV20D FC/MC62D