York YHJF18 THRU 60 warranty 1600

Page 24

510667-YTG-B-0509

HEATING PERFORMANCE DATA

CONDENSING UNIT MODEL NO

YHJF42S41S1

 

 

 

 

 

 

 

EVAPORATOR COIL MODEL NO

AHX60

 

 

 

 

 

 

 

 

AIR TEMP.

AIR TEMP.

 

 

 

 

ID CFM

 

 

 

 

ENTERING

ENTERING

 

1200

 

 

1400

 

 

1600

 

OUTDOOR UNIT

INDOOR COIL

 

 

 

 

 

 

 

 

 

MBTUH

KW

C.O.P.

MBTUH

KW

C.O.P.

MBTUH

KW

C.O.P.

 

 

 

 

 

 

 

 

 

 

 

 

60

45.3

4.1

2.8

45.0

4.1

2.7

44.6

4.2

2.6

60

 

 

 

 

 

 

 

 

 

 

70

45.1

3.8

3.0

44.9

3.8

2.9

44.6

3.9

2.8

 

 

 

 

 

 

 

 

 

 

 

 

80

44.9

3.5

3.3

44.8

3.6

3.1

44.7

3.6

3.0

 

 

 

 

 

 

 

 

 

 

 

 

60

41.3

4.1

2.5

41.2

4.1

2.5

41.1

4.1

2.4

47

 

 

 

 

 

 

 

 

 

 

70

40.7

3.6

2.8

40.7

3.7

2.7

40.7

3.7

2.6

 

 

 

 

 

 

 

 

 

 

 

 

80

40.0

3.3

3.1

40.2

3.3

3.0

40.3

3.4

2.9

 

 

 

 

 

 

 

 

 

 

 

 

60

38.2

3.8

2.5

38.4

3.9

2.4

38.5

3.9

2.3

40

 

 

 

 

 

 

 

 

 

 

70

37.4

3.4

2.8

37.7

3.5

2.7

38.1

3.5

2.6

 

 

 

 

 

 

 

 

 

 

 

 

80

36.6

3.1

3.0

37.1

3.1

3.0

37.7

3.2

2.9

 

 

 

 

 

 

 

 

 

 

 

 

60

33.3

3.4

2.4

33.4

3.4

2.4

33.5

3.4

2.3

30

 

 

 

 

 

 

 

 

 

 

70

32.7

3.0

2.7

32.8

3.1

2.6

32.9

3.1

2.5

 

 

 

 

 

 

 

 

 

 

 

 

80

32.0

2.7

3.0

32.2

2.8

2.9

32.3

2.8

2.8

 

 

 

 

 

 

 

 

 

 

 

 

60

26.7

2.9

2.2

26.9

2.9

2.2

27.2

2.8

2.2

17

 

 

 

 

 

 

 

 

 

 

70

25.2

2.5

2.5

20.9

2.5

2.4

26.7

2.5

2.5

 

 

 

 

 

 

 

 

 

 

 

 

80

23.6

2.1

2.8

14.9

2.2

2.7

26.3

2.3

2.7

 

 

 

 

 

 

 

 

 

 

 

 

60

22.8

2.5

2.3

23.3

2.5

2.2

23.8

2.5

2.2

10

 

 

 

 

 

 

 

 

 

 

70

22.9

2.2

2.6

23.2

2.3

2.5

23.6

2.3

2.4

 

 

 

 

 

 

 

 

 

 

 

 

80

22.9

2.1

2.8

23.1

2.1

2.8

23.3

2.1

2.7

NOTE: ALL CAPACITIES ARE NET (KBTUH) WITH INDOOR FAN HEAT ALREADY DEDUCTED AT 1250 BTUH/1000 CFM.

Multipliers for determining the performance with other indoor sections.

Air Handler

Coil

MBH

KW

COP

F6FP060

1.01

1.01

1.00

MV20D

FC/MC62D

1.00

1.01

1.00

Furnace

Coil

MBH

KW

COP

T*(8,L)X*C16

FC/MC62D

1.00

1.02

0.99

T*(8,L)X*C20

FC/MC62D

1.01

1.02

0.99

T*9X*C16

FC/MC62D

1.01

1.00

1.02

T*9X*C20

FC/MC62D

1.00

1.01

1.00

T*9X*D20

FC/MC62D

1.00

1.01

1.00

Y*(8,L)C*C20

FC/MC62D

1.01

1.00

1.01

(Y*9C/T*9V)*C16

FC/MC62D

1.02

0.97

1.06

(Y*9C/T*9V)*C20

FC/MC62D

1.01

0.98

1.04

(Y*9C/T*9V)*D20

FC/MC62D

1.01

0.99

1.03

24

Johnson Controls Unitary Products

Image 24
Contents Warranty FeaturesDescription Physical and Electrical Data ModelProcedures System Charge for Various Matched SystemsFootnotes Cooling Capacity With Air Handler Coils SensMV Variable Speed SpeedCooling Capacity With High Efficiency Motor Furnaces Unit Model Furnace Coil MODEL1 Stage Cooling RatedUnit Furnace Cooling Model MODEL1 Stage RatedSeer EER CFM Heating Performance With Air Handler Heating Capacity With Air Handler CoilsHeating Capacity With High Efficiency Motor Furnaces Model Furnace COIL1 ARI HEATING2 HspfWith Variable Speed FURNACES3 Model Furnace COIL1 ARI HEATING2 Accessories Seer HP with Variable Speed FURNACES3Typical Installation Typical Field WiringSQI Temperature Cooling Performance DataCondensing Entering AIRID WB F 21.7 MV12B FC/MC43B MV16C FC/MC43C ID WB F 34.5 MV20D FC/MC62D Condensing Unit Model NO. YHJF48S41S1 Indoor Coil Model no Cooling Performance Data LOW CFM 1-STAGE Operation MV20D FC/MC62DCooling Performance Data High CFM 2-STAGE Operation High CFMHeating Performance Data EnteringOutdoor Unit Indoor Coil MBH COPYTG-B-0509 27.4 1200 1400 1600 1600 1800 MBH COP MV20D FC/MC62D