York YHJF18 THRU 60 Heating Performance With Air Handler, Heating Capacity With Air Handler Coils

Page 7

510667-YTG-B-0509

\

HEATING PERFORMANCE - With Air Handler

UNIT

AIR

 

COIL1

 

 

 

 

ARI HEATING2

 

 

 

MODEL*

HANDLER

 

MODEL

 

47°F

 

 

 

 

17°F

 

HSPF

 

 

 

 

MBH

COP

 

KW

 

MBH

 

COP

KW

STD

 

 

 

14.5 SEER HP WITH MV

- VARIABLE

SPEED

 

 

 

 

 

 

 

 

YHJF18S41S1

MV12B

 

FC/MC35B

18.0

3.76

 

1.40

 

11.0

 

2.48

1.30

8.50

MV12B

 

FC/MC43B

18.0

3.90

 

1.35

 

10.9

 

2.56

1.25

8.50

 

 

 

 

 

YHJF24S41S1

MV12B

 

FC/MC35B

22.2

3.68

 

1.77

 

14.9

 

2.46

1.77

8.50

MV12B

 

FC/MC43B

22.2

3.82

 

1.70

 

14.9

 

2.54

1.72

8.50

 

 

 

 

 

YHJF30S41S1

MV12B

 

FC/MC43B

30.0

3.88

 

2.27

 

18.8

 

2.68

2.06

9.00

MV16C

 

FC/MC43C

30.0

3.92

 

2.24

 

18.8

 

2.70

2.04

9.00

 

 

 

 

 

YHJF36S41S1

MV12B

 

FC/MC43B

36.0

3.74

 

2.82

 

24.4

 

2.52

2.84

8.20

MV16C

 

FC/MC43C

36.0

3.74

 

2.82

 

24.2

 

2.52

2.81

9.00

 

 

 

 

 

YHJF42S41S1

MV20D

 

FC/MC62D

40.5

4.02

 

2.95

 

26.0

 

2.76

2.76

9.00

YHJF48S41S1

MV20D

 

FC/MC62D

48.0

3.82

 

3.68

 

31.8

 

2.60

3.58

9.00

 

 

14.5

SEER HP WITH AV / SV /

F*FV - VARIABLE SPEED

 

 

 

 

 

 

YHJF18S41S1

AV*36

 

18.0

3.98

 

1.33

 

10.8

 

2.62

1.21

8.50

YHJF24S41S1

AV*36

 

22.0

3.70

 

1.74

 

14.8

 

2.50

1.73

8.50

YHJF30S41S1

AV*36

 

29.8

3.98

 

2.19

 

18.6

 

2.74

1.99

9.00

YHJF36S41S1

AV*36

 

36.0

3.78

 

2.79

 

24.2

 

2.54

2.79

9.00

 

 

 

14.5 SEER HP WITH AHP

/ SHP /

AHX / F*FP

 

 

 

 

 

 

 

 

YHJF18S41S1

AHX30

 

18.0

3.88

 

1.36

 

10.9

 

2.52

1.27

8.50

 

AHX30

 

22.2

3.64

 

1.79

 

13.7

 

2.42

1.66

8.50

YHJF24S41S1

F6FP030

 

22.2

3.64

 

1.79

 

15.1

 

2.42

1.83

8.20

F6FP036

 

22.2

3.68

 

1.77

 

15.0

 

2.46

1.79

8.50

 

 

 

 

 

 

AHX36

 

22.4

3.70

 

1.77

 

15.1

 

2.46

1.80

8.50

YHJF30S41S1

AHX36

 

30.0

4.00

 

2.20

 

18.7

 

2.76

1.99

9.00

F6FP042

 

30.0

4.00

 

2.20

 

18.7

 

2.76

1.99

9.00

 

 

 

 

 

 

AHX36

 

36.0

3.82

 

2.76

 

24.2

 

2.56

2.77

9.00

YHJF36S41S1

AHX42

 

36.0

3.84

 

2.75

 

22.2

 

2.56

2.54

9.00

 

F6FP042

 

36.0

3.88

 

2.72

 

24.4

 

2.60

2.75

9.00

YHJF42S41S1

AHX60

 

40.5

4.00

 

2.97

 

26.0

 

2.74

2.78

9.00

F6FP060

 

41.0

4.04

 

2.97

 

26.2

 

2.74

2.80

9.00

 

 

 

 

 

YHJF48S41S1

AHX60

 

48.0

3.82

 

3.68

 

31.6

 

2.60

3.56

9.00

F6FP060

 

48.0

3.82

 

3.68

 

31.6

 

2.60

3.56

9.00

 

 

 

 

 

See notes below.

 

 

 

 

 

 

 

 

 

 

 

 

 

HEATING CAPACITY - With Air Handler Coils

UNIT

AIR

COIL1

 

 

 

HEATING2

 

 

MODEL

HANDLER

MODEL

 

STAGE

RATED

NET MBH

HSPF

COP @ 47

 

CFM

47 OD

17 OD

 

 

 

 

 

 

 

 

 

14.5 SEER

HP WITH MV

- VARIABLE

SPEED

 

 

 

 

 

 

 

1

1160

43.0

YHJF60S41S1

MV20D

FC/MC62D

 

2

1855

57.0

40.5

9.00

3.66

 

 

 

 

 

 

 

 

 

 

 

 

 

 

2

1160

54.9

39.0

8.85

3.04

 

 

 

14.5 SEER HP WITH AHX

 

 

 

 

 

 

 

 

1

1160

43.1

YHJF60S41S1

AHX60

 

 

 

 

 

 

 

 

2

1855

58.0

40.0

9.00

3.72

 

 

 

 

 

 

 

 

 

 

 

 

 

 

2

1170

57.5

40.0

8.90

3.24

 

 

 

 

 

 

 

 

 

 

Rated in accordance with DOE test procedures (Federal Register 12-27-79 and 3-18-88) and ARI Standards 210. Cooling MBH based on 80°F entering air temperature, 50% RH, and rated air flow.

EER (Energy Efficiency Ratio) is the total cooling output in BTU’s at 95°F outdoor ambient divided by the total electric power in watt-hours at those conditions. SEER (Seasonal Energy Efficiency Ratio) is the total cooling output in BTU’s during a normal annual usage period for cooling divided by the total electric power input in watt-hours during the same period.

1.Rated CFM same as for cooling.

2.Heating MBH based on ARI standards of 70° DB entering indoor air, 72% RH outdoor air with 25 feet of interconnecting piping and no supplemental electric heat operation.

CP equals MBH output divided by (total KW input x 3.412).

HSPF (Heating Seasonal Performance Factor) is the total heating output during a normal annual usage period for heating divided by the total electric power input during the same period.

— = Not Applicable.

Johnson Controls Unitary Products

7

Image 7
Contents Features WarrantyDescription Model Physical and Electrical DataSystem Charge for Various Matched Systems ProceduresFootnotes Speed Cooling Capacity With Air Handler CoilsSens MV Variable SpeedUnit Model Furnace Coil MODEL1 Stage Cooling Rated Cooling Capacity With High Efficiency Motor FurnacesCooling Model MODEL1 Stage Rated Unit FurnaceSeer EER CFM Heating Capacity With Air Handler Coils Heating Performance With Air HandlerModel Furnace COIL1 ARI HEATING2 Hspf Heating Capacity With High Efficiency Motor FurnacesWith Variable Speed FURNACES3 Model Furnace COIL1 ARI HEATING2 Seer HP with Variable Speed FURNACES3 AccessoriesTypical Field Wiring Typical InstallationSQI Entering AIR TemperatureCooling Performance Data CondensingID WB F 21.7 MV12B FC/MC43B MV16C FC/MC43C ID WB F 34.5 MV20D FC/MC62D Condensing Unit Model NO. YHJF48S41S1 Indoor Coil Model no MV20D FC/MC62D Cooling Performance Data LOW CFM 1-STAGE OperationHigh CFM Cooling Performance Data High CFM 2-STAGE OperationMBH COP Heating Performance DataEntering Outdoor Unit Indoor CoilYTG-B-0509 27.4 1200 1400 1600 1600 1800 MBH COP MV20D FC/MC62D