4-way Air Discharge Cassette Type

Cleaning the air filter

The fan is running for self cleaning maintenance after running the cooling or dry mode. Terminate the self cleaning mode forcibly when maintaining the air conditioner.

If is displayed on the remote control, clean the air filter.

1.Open the return air grille by sliding the latches. Let the grille drop while holding it.

Return air grille

Knob

Owner’s Manual

8.Push button to reset filter timer.

• “FILTER ” disappears.

CAUTION

Do not start the air conditioner while leaving the panel and air filter removed.

Cleaning Unit Grille and Frame

To clean the grille and the frame, wipe the outside with a soft, dry cloth. If necessary, a mild liquid detergent can be applied and wiped off with a dry cloth.

Cleaning The Louvers

1.Remove the discharge louver by holding it at both ends and pulling downwards towards the center.

2. Remove the air filter from grille.

2.Clean the louvers with water or mild detergent.

3.Mount the discharge louver by inserting one end and bending it outwards to allow the other end to be inserted.

Strap to prevent falling

Air filter

3.

Vacuum the filter and rinse it with water.

4.

Dry the filter.

1) Insert

NOTE

2)Insert in the louver sagging down the center downward.

5.

Wipe the inside of the return air grille with water or

 

mild detergent and then dry it.

6.

Reinstall the filter.

7.

Close the grille and secure it to the frame by the

 

latches.

Return air grille

Knob

When installing the louvers, make sure the side with marking faces upwards.

Preparing for long Shut Down Period

1.Clean the filters and repostion them in unit.

2.Operate the unit in fan mode for 3 or 4 hours to dry all internal parts.

3.Turn the unit off and disconnect the main power supply.

4.Before unit is turned on again, make sure the circuit breaker has been turned on for at least 12 hours.

21-EN

– 21 –

Image 22
Contents AIR Conditioner Split Type Contents Precautions for Safety Way Air Discharge Cassette Type System Characteristics Energy Saving Recommendations Select a comfortable set point and minimize adjusting itChecks before operating „ Outdoor unit Part Names„ Indoor unit Part sold separatelyWired Remote Control „ Display sectionPre-heat display Self cleaning displayPower saving mode display No function displayButton Remote control sensor„ Operation section Operation lampStart Correct Usage„ Preparation StopWhen restarting the operation after stop Auto ChangeoverCancel of timer operation Timer Operation„ Timer operation SetLouver Direction For cooling For heatingHeat operation Display when stopping the swingSet louver direction COOL/DRY operationOperation Select a louver you want to adjust by„ Set louver direction individually Pushing right side of the buttonTo stop self cleaning, push button twice in succession Power Saving ModeSelf Cleaning Mode Push button during operationAdvanced Settings „ Swing mode„ Louver lock No swing Push button to complete the settingPush button to lock the louver Push Time buttons to adjust the power-save setting „ Cancel louver lock„ Change power saving mode setting Push left side of button to select an indoor unit to be setBe sure to clean the heat exchanger with pressurized water MaintenancePeriodic Maintenance Replacing antibacterial glassCleaning The Louvers Cleaning the air filterCleaning Unit Grille and Frame Preparing for long Shut Down PeriodElectrical wiring Information for InstallationInstallation place Do not install the air conditioner in the following placesRe-Installation MaintenanceBe careful with noise or vibrations Indoor unit or outdoor unit makes a strange noise Trouble ShootingFan does not stop when the operation is stopped RecheckProtective device When the protective device is activatedDo not turn off the circuit breaker Memo EH99933501