1. PRECAUTIONS FOR SAFETY

WARNING

WARNINGS ABOUT INSTALLATION

Make sure to ask the qualified installation professional in electric work to install the air conditioner.

If the air conditioner is inappropriate installed by yourself, it may cause water leak, electric shock, fire, and so on.

• Be sure to connect ground wire. (grounding work) Incomplete grounding cause an electric shock.

Do not connect ground wires to gas pipes, water pipes, lightning rods or ground wires for telephone wires.

• If you install the indoor unit in a small room, take appropriate measures to prevent the refrigerant from exceeding the limit concentration even if it leaks.

Consult the dealer from whom you purchased the air conditioner when you implement the measures. Accumulation of highly-concentrated refrigerant may cause an oxygen deficiency accident.

• Check whether the piping work has been properly completed.

When existing pipes are used and if they are not constructed properly, the refrigerant gas may leak. Contact the installation company and confirm that the piping work has been properly completed. For details of installation of the air conditioner, refer to the Installation Manual. Use tools and piping materials for R410 only. Failure to do so or improper installation may cause a burst of pipe, resulting in injury.

WARNINGS ABOUT OPERATION

Cleaning of the air filter and other parts of the air filter involves dangerous work in high places, so be sure to have a service person do it.

The self cleaning function of the air conditioner causes the internal fan to run at a high speed in some modes even while the air conditioner is not working, which may cause injury.

Do not attempt it yourself.

Avoid cooling the room too strong or exposing the human body to cool breeze for a long time as it is bad for the health.

When you notice something abnormal with the air conditioner (smells like something scorching, poor cooling, etc.), immediately turn off the main switch and the circuit breaker, from the mains to stop the air conditioner, and contact the dealer.

If the air conditioner is continuously operated with something abnormal, it may cause machine failure, electric shock, fire, and so on.

WARNINGS ABOUT MOVEMENT AND REPAIR

• When the air conditioner cannot cool or heat a room well, contact the dealer from whom you purchased the air

 

conditioner as refrigerant leakage is considered as the cause. In the case of repair that requires refill of refrigerant,

 

ask service personnel about details of the repair.

 

The refrigerant used in the air conditioner is harmless.

 

Generally, the refrigerant does not leak. However, if the refrigerant leaks in a room and a heater or stove burner in

 

the room catches fire, it may generate toxic gas.

 

When you ask service personnel for repairing refrigerant leakage, confirm that the leakage portion has been

 

completely repaired.

 

• Do not move or repair any unit by yourself.

 

Since there is high voltage inside the unit, you may get electric shock when removing the cover and main unit.

 

• Whenever the air conditioner needs repair, make sure to ask the dealer to do it.

 

If it is repaired imperfectly, it may cause electric shock or fire.

 

• When moving the air conditioner for re-installing at another place, ask the dealer to do it. If it is imperfectly installed,

EN

it may cause electric shock or fire.

– 2 –

2-EN

Image 3
Contents AIR Conditioner Split Type Contents Precautions for Safety Way Air Discharge Cassette Type System Characteristics Select a comfortable set point and minimize adjusting it Energy Saving RecommendationsChecks before operating Part sold separately Part Names„ Indoor unit „ Outdoor unit„ Display section Wired Remote ControlNo function display Self cleaning displayPower saving mode display Pre-heat displayOperation lamp Remote control sensor„ Operation section ButtonStop Correct Usage„ Preparation StartAuto Changeover When restarting the operation after stopSet Timer Operation„ Timer operation Cancel of timer operationFor cooling For heating Louver DirectionCOOL/DRY operation Display when stopping the swingSet louver direction Heat operationPushing right side of the button Select a louver you want to adjust by„ Set louver direction individually OperationPush button during operation Power Saving ModeSelf Cleaning Mode To stop self cleaning, push button twice in succession„ Swing mode Advanced SettingsPush button to complete the setting „ Louver lock No swingPush button to lock the louver Push left side of button to select an indoor unit to be set „ Cancel louver lock„ Change power saving mode setting Push Time buttons to adjust the power-save settingReplacing antibacterial glass MaintenancePeriodic Maintenance Be sure to clean the heat exchanger with pressurized waterPreparing for long Shut Down Period Cleaning the air filterCleaning Unit Grille and Frame Cleaning The LouversDo not install the air conditioner in the following places Information for InstallationInstallation place Electrical wiringMaintenance Re-InstallationBe careful with noise or vibrations Recheck Trouble ShootingFan does not stop when the operation is stopped Indoor unit or outdoor unit makes a strange noiseWhen the protective device is activated Protective deviceDo not turn off the circuit breaker Memo EH99933501