York DY 036 warranty DY048 / 4 Ton

Page 10

 

 

 

 

 

 

 

 

 

343615-YTG-A-0807

TABLE 8: DY048 INDOOR SOUND POWER LEVELS (HORIZONTAL DUCTED INLET)

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

UNIT DESCRIPTION / MODEL

 

 

 

DY048 / 4 Ton

 

 

 

 

 

CONFIGURATION

 

 

 

Horizontal Ducted Inlet

 

 

 

 

 

Indoor Blower Speed (RPM)

766

769

1077

1087

 

 

Blower Static Pressure (IWG)

0.2

0.5

0.4

1.0

 

 

Airflow (CFM)

1484

993

2270

1406

 

 

Blower Motor BHP

0.67

0.54

1.24

0.90

 

 

 

ID Blower

Cooling

ID Blower

Cooling

ID Blower

 

Cooling

ID Blower

Cooling

 

 

Octave Center Freq.

Operation2

Operation2

 

Operation2

Operation2

 

 

Only (dB)

(dB)

Only (dB)

(dB)

Only (dB)

 

(dB)

Only (dB)

(dB)

 

 

 

 

 

 

 

 

63

74

97

74

95

77

 

90

77

90

 

 

125

70

86

69

86

73

 

78

72

77

 

 

250

53

58

52

57

60

 

61

58

61

 

 

500

49

55

47

54

54

 

56

51

53

 

 

1000

42

42

38

39

50

 

55

45

45

 

 

2000

40

44

38

43

48

 

51

45

46

 

 

4000

38

44

36

41

48

 

52

43

45

 

 

8000

42

43

42

44

45

 

48

44

45

 

1.Tested in accordance with ARI Standard 260. Refer to 2001 Standard for Sound Rating of Ducted Air Moving and Conditioning Equipment .

2.Cooling Operation – ID blower, compressor and outdoor fan operating.

3.Test Duct Dimension: 12 in. wide x 18 in. high x 8 ft. long (0.30m x 0.46m x 2.44m).

4.Test duct termination is flush with reverberation room wall.

5.Duct end (sound reflection) correction: (11, 6, 3, 1, 0, 0, 0, 0) dB at (63, 125, 250, 500, 1k, 4k, 8k) Hz.

TABLE 9: DY048 INDOOR SOUND POWER LEVELS (HORIZONTAL DUCTED DISCHARGE)

UNIT DESCRIPTION / MODEL

 

 

 

DY048 / 4 Ton

 

 

 

CONFIGURATION

 

 

Horizontal Ducted Discharge

 

 

Indoor Blower Speed (RPM)

766

769

1077

1087

Blower Static Pressure (IWG)

0.2

0.5

0.4

1.0

Airflow (CFM)

1484

993

2270

1406

Blower Motor BHP

0.67

0.54

1.24

0.90

 

ID Blower

Cooling

ID Blower

Cooling

ID Blower

Cooling

ID Blower

Cooling

Octave Center Freq.

Operation2

Operation2

Operation2

Operation2

 

Only (dB)

(dB)

Only (dB)

(dB)

Only (dB)

(dB)

Only (dB)

(dB)

 

 

 

 

 

63

77

97

75

95

84

91

82

91

125

72

86

69

85

81

83

78

80

250

60

62

57

59

71

71

66

67

500

53

56

49

54

60

61

55

56

1000

47

47

42

43

58

59

52

52

2000

45

46

40

43

54

55

50

50

4000

46

47

40

42

57

58

52

52

8000

47

47

45

45

54

54

48

49

1.Tested in accordance with ARI Standard 260. Refer to 2001 Standard for Sound Rating of Ducted Air Moving and Conditioning Equipment .

2.Cooling Operation – ID blower, compressor and outdoor fan operating.

3.Test Duct Dimension: 12 in. wide x 18 in. high x 8 ft. long (0.30m x 0.46m x 2.44m).

4.Test duct termination is flush with reverberation room wall.

5.Duct end (sound reflection) correction: (11, 6, 3, 1, 0, 0, 0, 0) dB at (63, 125, 250, 500, 1k, 4k, 8k) Hz.

10

Unitary Products Group

Image 10
Contents Warranty DescriptionTable of Contents Product Nomenclature Ton Sunline Magnum Model Number NomenclatureFeatures FACTORY-INSTALLED Options Unit CutawayFIELD-INSTALLED Accessories GAS Heat RATINGS1 Capacity Ratings ARI 210/2401Stage GAS Heat Ratings Configuration Horizontal Ducted InletVertical Ducted Inlet DY048 / 4 Ton 791 794 1084 1095 DY060 / 5 Ton 834 840 1171 1194 DY036 Cooling Capacities 3 TON MBHDY048 Cooling Capacities 4 TON DY060 Cooling Capacities 5 TON 1500MED Static Resistances Electric Heater CFM LimitationsAmps Ampacity Size Each FLA Tonnage RLA LRA Motor Outlet None 34.4 2CE04510506 19.2 46.5 208-1-60 YTG-A-0807 Electric Heat Correction Factors DY Physical DataVoltage LIMITATIONS1 Typical Power Wiring Unit Dimensions 3 5 TON COOLING/GAS Heat Front View Detail a Unit Dimensions Rear View Minimum Clearances Typical Applications Center of Gravity Unit TotalOperating Weights LBS Roof Curb DimensionsOutdoor Condenser FAN Assembly Guide SpecificationsIndoor Evaporator FAN Assembly Unit CabinetGAS Heating Section Single or 2 Stage Unit Operating CharacteristicsUnit Controls Electric Heating SectionElectric Heaters Other PRE-ENGINEERED Accessories AvailableManual Outdoor AIR Damper YTG-A-0807 YTG-A-0807 YTG-A-0807

DY 036 specifications

The York DY 036 is a prominent model in the realm of air conditioning systems, particularly known for its efficiency and advanced features. Designed for both residential and commercial applications, the DY 036 stands out due to its exceptional performance and energy savings.

One of the primary features of the York DY 036 is its energy efficiency. With a Seasonal Energy Efficiency Ratio (SEER) rating that exceeds industry standards, this air conditioning unit is engineered to deliver cooling power while minimizing electricity consumption. This makes it an ideal choice for consumers looking to reduce their energy bills without sacrificing comfort.

Equipped with advanced inverter technology, the DY 036 adjusts its cooling output in response to the ambient temperature. This not only enhances comfort by maintaining a consistent indoor climate but also contributes to lower energy use. The inverter system allows the unit to operate at a variable speed, preventing the frequent on-and-off cycling associated with traditional models, which can be a significant energy drain.

Another compelling characteristic of the York DY 036 is its quiet operation. With sound levels kept to a minimum, this model is perfect for installation in environments where noise disturbances are a concern, such as bedrooms or office settings. The use of innovative sound-dampening technology ensures that the system runs unobtrusively, providing comfort without disruptive noise.

The DY 036 also incorporates an advanced filtration system that improves indoor air quality. Its multi-stage filtration process captures dust, allergens, and other pollutants, ensuring a healthier breathing environment for occupants. Regular maintenance is also streamlined with easy-access panels, allowing homeowners and technicians to perform servicing without hassle.

Durability is another hallmark of the York DY 036. Built with high-quality materials and components, it is designed to withstand varying climate conditions, ensuring long-lasting reliability. The unit also boasts advanced corrosion resistance, making it suitable for environments with high humidity or proximity to saltwater.

In summary, the York DY 036 is a cutting-edge air conditioning model that provides energy efficiency, quiet operation, advanced filtration, and durable construction. Whether for residential or commercial use, it represents a blend of comfort, technology, and reliability that meets the demands of modern climate control.