York DY 036 warranty Other PRE-ENGINEERED Accessories Available, Electric Heaters

Page 33

343615-YTG-A-0807

OPTIONAL OUTDOOR AIR (Shall be made available by either/or):

ELECTRONIC ENTHALPY AUTOMATIC ECONO- MIZER- Outdoor and return air dampers that are inter- locked and positioned by a fully-modulating, spring return damper actuator. The maximum leakage rate for the outdoor air intake dampers shall not exceed 2% when dampers are fully closed and operating against a pressure differential of 0.5 IWG. A unit-mounted potenti- ometer shall be provided to adjust the outdoor and return air damper assembly to take in CFM of outdoor air to meet the minimum ventilation requirement of the condi- tioned space during normal operation. During econo- mizer operation, a mixed-air temperature control shall modulate the outdoor and return air damper assembly to prevent the supply air temperature from dropping below 55°F. Changeover from compressor to economizer oper- ation shall be provided by an integral electronic enthalpy control that feeds input into the basic module. The out- door intake opening shall be covered with a rain hood that matches the exterior of the unit. Water eliminator/fil- ters shall be provided. Simultaneous economizer/com- pressor operation is also possible. Dampers shall fully close on power loss.

MOTORIZED OUTDOOR AIR DAMPERS - Outdoor air dampers are positioned by a 2-position,spring-return damper actuator. The maximum leakage rate for the out- door air intake dampers shall not exceed 2% when dampers are fully closed and operating against a pres- sure differential of 0.5 IWG. A unit-mounted potentiome- ter shall be provided to adjust the outdoor damper assembly to take in the design CFM of outdoor air to meet the ventilation requirements of the conditioned space during normal operation. Whenever the indoor fan motor is energized, the dampers open up to one of two pre-selected positions - regardless of the outdoor air enthalpy. Dampers return to the fully closed position when the indoor fan motor is de-energized. Dampers shall fully close on power loss.

OTHER PRE-ENGINEERED ACCESSORIES AVAILABLE

ROOF CURB - 14"and 8” high, full perimeter curb with wood nailer (shipped knocked-down).

BAROMETRIC RELIEF DAMPER - Contains a rain hood, air inlet screen, exhaust damper and mounting hardware. Used to relieve internal air pressure through the unit.

PROPANE CONVERSION KIT - Contains new orifices and gas valve parts to convert from natural to L.P. gas. One per unit required.

HIGH ALTITUDE - NATURAL GAS - Contains orifices required for applications between 2000 and 6000 feet altitude.

HIGH ALTITUDE - PROPANE GAS - Contains orifices required for applications between 2000 and 6000 feet altitude. Must be used with propane conversion kit.

LOW NOX - Required to reduce the emission of nitrogen oxides below 40 nanograms per joule.

GAS PIPING - Contains 1/2” pipe nipples, fittings and gas cock (including panel assess gaskets) required for bottom gas supply connection with external shut off.

POWER EXHAUST OPTION - To work in conjunction with economizers.

ELECTRIC HEATERS

ECONOMIZER/MOTORIZED DAMPER RAIN HOOD - Contains all hood panels and the hardware for assem- bling.

MANUAL OUTDOOR AIR DAMPER

COIL GUARD KIT - Guard for cooling coil.

HAIL GUARD

FLUE EXHAUST EXTENSION

OTHER FACTORY INSTALLED OPTIONS

POWER EXHAUST OPTION - To work in conjunction with economizers.

STAINLESS STEEL HEAT EXCHANGER

STAINLESS STEEL DRAIN PAN

BOTTOM DRAIN CONNECTION

TECHNICOAT PHENOLIC COATED CONDENSER AND EVAPORATOR COIL

ELECTRONIC SINGLE ENTHALPY ECONOMIZER

DIRTY FILTER SWITCH

PHASE MONITOR

COIL GUARD

POWERED GFI CONVENIENCE OUTLET

NON-POWERED GFI CONVENIENCE OUTLET

BAS CONTROLS (Simplicity® INTELLI-Comfort™,

CPC, JOHNSON, HONEYWELL, NOVAR)

BAS READY ECONOMIZER (2-10 V.D.C. ACTUATOR WITHOUT A CONTROLLER)

HINGED FILTER DOOR ACCESS AND TOOLESS ACCESS PANELS

2" PLEATED FILTERS

DISCONNECT SWITCH

SUPPLY AIR SMOKE DETECTOR

RETURN AIR SMOKE DETECTOR

Unitary Products Group

33

Image 33
Contents Description WarrantyTable of Contents Ton Sunline Magnum Model Number Nomenclature Product NomenclatureFeatures Unit Cutaway FACTORY-INSTALLED OptionsFIELD-INSTALLED Accessories Capacity Ratings ARI 210/2401 GAS Heat RATINGS1Stage GAS Heat Ratings Horizontal Ducted Inlet ConfigurationVertical Ducted Inlet DY048 / 4 Ton 791 794 1084 1095 DY060 / 5 Ton 834 840 1171 1194 MBH DY036 Cooling Capacities 3 TONDY048 Cooling Capacities 4 TON 1500 DY060 Cooling Capacities 5 TONMED Electric Heater CFM Limitations Static ResistancesAmps Ampacity Size Each FLA Tonnage RLA LRA Motor Outlet None 34.4 2CE04510506 19.2 46.5 208-1-60 YTG-A-0807 DY Physical Data Electric Heat Correction FactorsVoltage LIMITATIONS1 Typical Power Wiring Unit Dimensions 3 5 TON COOLING/GAS Heat Front View Detail a Unit Dimensions Rear View Minimum Clearances Typical Applications Unit Total Center of GravityRoof Curb Dimensions Operating Weights LBSIndoor Evaporator FAN Assembly Guide SpecificationsOutdoor Condenser FAN Assembly Unit CabinetUnit Controls Unit Operating CharacteristicsGAS Heating Section Single or 2 Stage Electric Heating SectionOther PRE-ENGINEERED Accessories Available Electric HeatersManual Outdoor AIR Damper YTG-A-0807 YTG-A-0807 YTG-A-0807

DY 036 specifications

The York DY 036 is a prominent model in the realm of air conditioning systems, particularly known for its efficiency and advanced features. Designed for both residential and commercial applications, the DY 036 stands out due to its exceptional performance and energy savings.

One of the primary features of the York DY 036 is its energy efficiency. With a Seasonal Energy Efficiency Ratio (SEER) rating that exceeds industry standards, this air conditioning unit is engineered to deliver cooling power while minimizing electricity consumption. This makes it an ideal choice for consumers looking to reduce their energy bills without sacrificing comfort.

Equipped with advanced inverter technology, the DY 036 adjusts its cooling output in response to the ambient temperature. This not only enhances comfort by maintaining a consistent indoor climate but also contributes to lower energy use. The inverter system allows the unit to operate at a variable speed, preventing the frequent on-and-off cycling associated with traditional models, which can be a significant energy drain.

Another compelling characteristic of the York DY 036 is its quiet operation. With sound levels kept to a minimum, this model is perfect for installation in environments where noise disturbances are a concern, such as bedrooms or office settings. The use of innovative sound-dampening technology ensures that the system runs unobtrusively, providing comfort without disruptive noise.

The DY 036 also incorporates an advanced filtration system that improves indoor air quality. Its multi-stage filtration process captures dust, allergens, and other pollutants, ensuring a healthier breathing environment for occupants. Regular maintenance is also streamlined with easy-access panels, allowing homeowners and technicians to perform servicing without hassle.

Durability is another hallmark of the York DY 036. Built with high-quality materials and components, it is designed to withstand varying climate conditions, ensuring long-lasting reliability. The unit also boasts advanced corrosion resistance, making it suitable for environments with high humidity or proximity to saltwater.

In summary, the York DY 036 is a cutting-edge air conditioning model that provides energy efficiency, quiet operation, advanced filtration, and durable construction. Whether for residential or commercial use, it represents a blend of comfort, technology, and reliability that meets the demands of modern climate control.