York DY 036 warranty Static Resistances, Electric Heater CFM Limitations

Page 18

343615-YTG-A-0807

TABLE 21: STATIC RESISTANCES

 

 

 

 

 

 

 

RESISTANCE, IWG

 

 

 

 

DESCRIPTION

 

 

 

 

 

 

CFM

 

 

 

 

 

 

 

 

1000

1200

1400

1600

1800

2000

2200

2400

2600

2800

3000

ECONOMIZER1,3

 

0.07

0.08

0.09

0.11

0.13

0.15

0.17

0.20

0.23

0.26

0.30

ELECTRIC

 

7-15KW

0.04

0.05

0.06

0.07

0.08

0.10

0.12

0.14

0.16

0.19

0.22

HEATERS1

 

 

 

 

 

 

 

 

 

 

 

 

 

 

20-30KW

0.06

0.07

0.08

0.09

0.11

0.13

0.15

0.17

0.20

0.23

0.26

COOLING ONLY

2

 

0.08

0.10

0.12

0.14

0.16

0.18

0.20

0.23

0.26

0.29

0.32

1.Deduct these resistance values from the available external static pressure shown in SUPPLY AIR BLOWER PERFORMANCE Tables.

2.Add these resistance values to the available static resistance values on SUPPLY AIR BLOWER PERFORMANCE Tables.

3.The pressure through the economizer is greater for 100% outdoor air than for 100% return air. If the resistance of the return air duct system is less than 0.25 IWG, the unit will deliver less CFM during full economizer operation.

TABLE 22: ELECTRIC HEATER CFM LIMITATIONS

UNIT MODEL SIZE

 

 

 

MINIMUM SUPPLY AIR CFM

 

 

VOLTAGE

 

 

HEATER SIZE NOMINAL KW

 

 

NOMINAL TONS

 

 

 

 

 

 

5

7

10

15

20

30

 

208/230-1-60

1100

1100

1200

1200

1300

-

3

208/230-3-60

1100

1100

1200

1200

1300

-

460-3-60

-

1100

1200

1200

1300

-

 

 

 

 

 

 

 

 

 

 

575-3-60

-

-

1200

1200

1300

-

 

208/230-1-60

1300

1300

1300

1300

1300

-

4

208/230-3-60

1300

1300

1300

1300

1300

-

 

 

 

 

 

 

 

460-3-60

-

1300

1300

1300

1300

-

 

 

 

 

 

 

 

 

 

 

575-3-60

-

-

1300

1300

1400

-

 

208/230-1-60

1600

1600

1600

1600

1600

1600

5

208/230-3-60

1600

1600

1600

1600

1600

1600

 

 

 

 

 

 

 

460-3-60

1600

1600

1600

1600

1600

1600

 

 

575-3-60

-

1600

1600

1600

1600

1800

18

Unitary Products Group

Image 18
Contents Warranty DescriptionTable of Contents Product Nomenclature Ton Sunline Magnum Model Number NomenclatureFeatures FACTORY-INSTALLED Options Unit CutawayFIELD-INSTALLED Accessories Capacity Ratings ARI 210/2401 GAS Heat RATINGS1Stage GAS Heat Ratings Configuration Horizontal Ducted InletVertical Ducted Inlet DY048 / 4 Ton 791 794 1084 1095 DY060 / 5 Ton 834 840 1171 1194 DY036 Cooling Capacities 3 TON MBHDY048 Cooling Capacities 4 TON DY060 Cooling Capacities 5 TON 1500MED Static Resistances Electric Heater CFM LimitationsAmps Ampacity Size Each FLA Tonnage RLA LRA Motor Outlet None 34.4 2CE04510506 19.2 46.5 208-1-60 YTG-A-0807 DY Physical Data Electric Heat Correction FactorsVoltage LIMITATIONS1 Typical Power Wiring Unit Dimensions 3 5 TON COOLING/GAS Heat Front View Detail a Unit Dimensions Rear View Minimum Clearances Typical Applications Center of Gravity Unit TotalOperating Weights LBS Roof Curb DimensionsOutdoor Condenser FAN Assembly Guide SpecificationsIndoor Evaporator FAN Assembly Unit CabinetGAS Heating Section Single or 2 Stage Unit Operating CharacteristicsUnit Controls Electric Heating SectionOther PRE-ENGINEERED Accessories Available Electric HeatersManual Outdoor AIR Damper YTG-A-0807 YTG-A-0807 YTG-A-0807

DY 036 specifications

The York DY 036 is a prominent model in the realm of air conditioning systems, particularly known for its efficiency and advanced features. Designed for both residential and commercial applications, the DY 036 stands out due to its exceptional performance and energy savings.

One of the primary features of the York DY 036 is its energy efficiency. With a Seasonal Energy Efficiency Ratio (SEER) rating that exceeds industry standards, this air conditioning unit is engineered to deliver cooling power while minimizing electricity consumption. This makes it an ideal choice for consumers looking to reduce their energy bills without sacrificing comfort.

Equipped with advanced inverter technology, the DY 036 adjusts its cooling output in response to the ambient temperature. This not only enhances comfort by maintaining a consistent indoor climate but also contributes to lower energy use. The inverter system allows the unit to operate at a variable speed, preventing the frequent on-and-off cycling associated with traditional models, which can be a significant energy drain.

Another compelling characteristic of the York DY 036 is its quiet operation. With sound levels kept to a minimum, this model is perfect for installation in environments where noise disturbances are a concern, such as bedrooms or office settings. The use of innovative sound-dampening technology ensures that the system runs unobtrusively, providing comfort without disruptive noise.

The DY 036 also incorporates an advanced filtration system that improves indoor air quality. Its multi-stage filtration process captures dust, allergens, and other pollutants, ensuring a healthier breathing environment for occupants. Regular maintenance is also streamlined with easy-access panels, allowing homeowners and technicians to perform servicing without hassle.

Durability is another hallmark of the York DY 036. Built with high-quality materials and components, it is designed to withstand varying climate conditions, ensuring long-lasting reliability. The unit also boasts advanced corrosion resistance, making it suitable for environments with high humidity or proximity to saltwater.

In summary, the York DY 036 is a cutting-edge air conditioning model that provides energy efficiency, quiet operation, advanced filtration, and durable construction. Whether for residential or commercial use, it represents a blend of comfort, technology, and reliability that meets the demands of modern climate control.