York DY 036 warranty Center of Gravity, Unit Total

Page 29

343615-YTG-A-0807

447/8A

BACK OF UNIT

447/8A

BACK OF UNIT

821/4

F

821/4

D

B

X

X

 

B

E

C

APPROXIMATE

CENTER OF GRAVITY

 

C

FRONT OF UNIT

Y

APPROXIMATE

CENTER OF GRAVITY

CONDENSER COIL

D

END OF UNIT

Y

FRONT OF UNIT

CONDENSER COIL

END OF UNIT

FIGURE 10 -FOUR AND SIX POINT LOADING

TABLE 30: DY 4 AND 6 POINT LOADS WEIGHT DISTRIBUTION

UNIT

TOTAL

 

4-Point Loading (lb)

 

 

 

6-Point Loading (lb)

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

A

 

B

C

 

D

A

B

 

C

D

 

E

F

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

DY036 Cooling/ Electric

575

132

 

125

155

 

164

89

85

 

82

102

 

106

110

DY036N04

615

141

 

133

166

 

175

95

91

 

88

110

 

114

118

DY036D06

625

143

 

135

168

 

178

96

93

 

89

111

 

115

120

DY036N08

635

145

 

138

171

 

181

98

94

 

91

113

 

117

122

DY036D10

645

148

 

140

174

 

184

99

96

 

92

115

 

119

124

DY048 Cooling/ Electric

585

134

 

127

158

 

167

90

87

 

84

104

 

108

112

DY048(D,N)06

635

145

 

138

171

 

181

98

94

 

91

113

 

117

122

DY048(D,N)10

655

150

 

142

177

 

187

101

97

 

94

117

 

121

125

DY060 Cooling/ Electric

590

135

 

128

159

 

168

91

88

 

84

105

 

109

113

DY060D06

640

147

 

139

173

 

182

99

95

 

92

114

 

118

123

DY060N08

650

149

 

141

175

 

185

100

97

 

93

116

 

120

125

DY060(D,N)10

660

151

 

143

178

 

188

102

98

 

95

118

 

122

126

TABLE 31: CENTER OF GRAVITY

DIMENSION

3 - 5 TON

 

 

X

40”

 

 

Y

20”

 

 

Unitary Products Group

29

Image 29
Contents Description WarrantyTable of Contents Ton Sunline Magnum Model Number Nomenclature Product NomenclatureFeatures Unit Cutaway FACTORY-INSTALLED OptionsFIELD-INSTALLED Accessories Stage GAS Heat Ratings Capacity Ratings ARI 210/2401GAS Heat RATINGS1 Horizontal Ducted Inlet ConfigurationVertical Ducted Inlet DY048 / 4 Ton 791 794 1084 1095 DY060 / 5 Ton 834 840 1171 1194 MBH DY036 Cooling Capacities 3 TONDY048 Cooling Capacities 4 TON 1500 DY060 Cooling Capacities 5 TONMED Electric Heater CFM Limitations Static ResistancesAmps Ampacity Size Each FLA Tonnage RLA LRA Motor Outlet None 34.4 2CE04510506 19.2 46.5 208-1-60 YTG-A-0807 Voltage LIMITATIONS1 DY Physical DataElectric Heat Correction Factors Typical Power Wiring Unit Dimensions 3 5 TON COOLING/GAS Heat Front View Detail a Unit Dimensions Rear View Minimum Clearances Typical Applications Unit Total Center of GravityRoof Curb Dimensions Operating Weights LBSIndoor Evaporator FAN Assembly Guide SpecificationsOutdoor Condenser FAN Assembly Unit CabinetUnit Controls Unit Operating CharacteristicsGAS Heating Section Single or 2 Stage Electric Heating SectionManual Outdoor AIR Damper Other PRE-ENGINEERED Accessories AvailableElectric Heaters YTG-A-0807 YTG-A-0807 YTG-A-0807

DY 036 specifications

The York DY 036 is a prominent model in the realm of air conditioning systems, particularly known for its efficiency and advanced features. Designed for both residential and commercial applications, the DY 036 stands out due to its exceptional performance and energy savings.

One of the primary features of the York DY 036 is its energy efficiency. With a Seasonal Energy Efficiency Ratio (SEER) rating that exceeds industry standards, this air conditioning unit is engineered to deliver cooling power while minimizing electricity consumption. This makes it an ideal choice for consumers looking to reduce their energy bills without sacrificing comfort.

Equipped with advanced inverter technology, the DY 036 adjusts its cooling output in response to the ambient temperature. This not only enhances comfort by maintaining a consistent indoor climate but also contributes to lower energy use. The inverter system allows the unit to operate at a variable speed, preventing the frequent on-and-off cycling associated with traditional models, which can be a significant energy drain.

Another compelling characteristic of the York DY 036 is its quiet operation. With sound levels kept to a minimum, this model is perfect for installation in environments where noise disturbances are a concern, such as bedrooms or office settings. The use of innovative sound-dampening technology ensures that the system runs unobtrusively, providing comfort without disruptive noise.

The DY 036 also incorporates an advanced filtration system that improves indoor air quality. Its multi-stage filtration process captures dust, allergens, and other pollutants, ensuring a healthier breathing environment for occupants. Regular maintenance is also streamlined with easy-access panels, allowing homeowners and technicians to perform servicing without hassle.

Durability is another hallmark of the York DY 036. Built with high-quality materials and components, it is designed to withstand varying climate conditions, ensuring long-lasting reliability. The unit also boasts advanced corrosion resistance, making it suitable for environments with high humidity or proximity to saltwater.

In summary, the York DY 036 is a cutting-edge air conditioning model that provides energy efficiency, quiet operation, advanced filtration, and durable construction. Whether for residential or commercial use, it represents a blend of comfort, technology, and reliability that meets the demands of modern climate control.