York DY 036 warranty Typical Power Wiring

Page 24

343615-YTG-A-0807

TYPICAL POWER WIRING

REFER TO THE ELECTRICAL DATA

TABLES TO SIZE THE DISCONNECT

SWITCH, OVERCURRENT PROTEC-

TION AND WIRING.

TYPICAL CONTROL WIRING

COOLING ONLY (24 VOLT THERMOSTAT)

THERMOSTAT1

UNIT TERMINAL

TERMINALS

STRIP TB1

 

RV

R

 

YC

Y1

24 VOLT

TRANSFORMER

 

Y2

 

GFG

C

124 VOLT THERMOSTAT 2TH07701024. TO CONTROL THE ECONOMIZER ON SECOND STAGE COOLING, USE THE THERMOSTAT 2TH0401224.

COOLING / HEATING (ELECTRONIC THERMOSTAT)

MULTI STAGE

THERMOSTAT1

 

 

 

TERMINALS

 

UNIT TERMINAL

 

ADD

RC

 

STRIP TB1

24 VOLT

RH

 

R

TRANSFORMER

JUMPER

 

Y1

 

Y1

 

 

 

 

 

Y2

2

Y2

 

4

W1

 

W1

 

W2

3

W2

 

 

G

 

G

 

BC

LED 1

 

 

X

LED 2

NOT

 

OCC

 

USED

4

 

COM

 

ADD

A1

JUMPER

A2

T TO REMOTE SENSOR

T 2TH040702224 IF USED

1ELECTRONIC PROGRAMMABLE THERMOSTAT 2ET04700224 (INCLUDES SUBBASE).

2SECOND STAGE COOLING IS NOT REQUIRED ON UNITS LESS ECONOMIZER.

3SECOND STAGE HEATING IS ONLY REQUIRED ON UNITS WITH A TWO STAGE ELECTRIC HEATER OR 2 STAGE GAS HEAT.

4REMOVE JUMPER J2 FROM TERMINALS 4 AND 9 ON JUMPER PLUG CONNECTOR P6 ON UNITS WITH ECONOMIZER. TERMINALS A1 AND A2 PROVIDE A RELAY OUT-PUT TO CLOSE THE OUTDOOR ECONOMIZER DAMPERS WHEN THE THERMOSTAT SWITCHES TO THE SET-BACK POSITION.

FIGURE 2 - TYPICAL FIELD POWER & CONTROL WIRING

COOLING / HEATING (24 VOLT THERMOSTAT)

THERMOSTAT1

TERMINALS

 

RH

UNIT TERMINAL

 

ADD

STRIP TB1

 

 

 

 

JUMPER

RC

R

 

 

Y

Y1

24 VOLT

 

 

Y2

TRANSFORMER

 

 

 

WW1

W2

GG

C

124 VOLT THERMOSTAT 2ET07701024. TO CONTROL THE ECONOMIZER ON THE SECOND STAGE COOLING OR TO HAVE AN ELECTRIC HEAT ACCESSORY WITH TWO STAGES OF HEAT, USE THERMOSTAT 2TH0471024.

COOLING / HEATING (ELECTRONIC THERMOSTAT)

SINGLE STAGE

 

THERMOSTAT1

UNIT TERMINAL

 

TERMINALS

 

 

 

 

STRIP TB1

 

 

RH

 

ADD

 

RC

 

 

R

 

 

Y

 

Y1

JUMPER

 

 

 

 

 

 

 

 

WW1

G

G

C

24 VOLT

TRANSFORMER

1ELECTRONIC PROGRAMMABLE THERMOSTAT 2ET07701024 (INCLUDES SUBBASE).

TO CONTROL THE ECONOMIZER ON SECOND STAGE COOLING, USE THERMOSTAT 2TH04700224.

24

Unitary Products Group

Image 24
Contents Warranty DescriptionTable of Contents Product Nomenclature Ton Sunline Magnum Model Number NomenclatureFeatures FACTORY-INSTALLED Options Unit CutawayFIELD-INSTALLED Accessories Capacity Ratings ARI 210/2401 GAS Heat RATINGS1Stage GAS Heat Ratings Configuration Horizontal Ducted InletVertical Ducted Inlet DY048 / 4 Ton 791 794 1084 1095 DY060 / 5 Ton 834 840 1171 1194 DY036 Cooling Capacities 3 TON MBHDY048 Cooling Capacities 4 TON DY060 Cooling Capacities 5 TON 1500MED Static Resistances Electric Heater CFM LimitationsAmps Ampacity Size Each FLA Tonnage RLA LRA Motor Outlet None 34.4 2CE04510506 19.2 46.5 208-1-60 YTG-A-0807 DY Physical Data Electric Heat Correction FactorsVoltage LIMITATIONS1 Typical Power Wiring Unit Dimensions 3 5 TON COOLING/GAS Heat Front View Detail a Unit Dimensions Rear View Minimum Clearances Typical Applications Center of Gravity Unit TotalOperating Weights LBS Roof Curb DimensionsGuide Specifications Indoor Evaporator FAN AssemblyOutdoor Condenser FAN Assembly Unit CabinetUnit Operating Characteristics Unit ControlsGAS Heating Section Single or 2 Stage Electric Heating SectionOther PRE-ENGINEERED Accessories Available Electric HeatersManual Outdoor AIR Damper YTG-A-0807 YTG-A-0807 YTG-A-0807

DY 036 specifications

The York DY 036 is a prominent model in the realm of air conditioning systems, particularly known for its efficiency and advanced features. Designed for both residential and commercial applications, the DY 036 stands out due to its exceptional performance and energy savings.

One of the primary features of the York DY 036 is its energy efficiency. With a Seasonal Energy Efficiency Ratio (SEER) rating that exceeds industry standards, this air conditioning unit is engineered to deliver cooling power while minimizing electricity consumption. This makes it an ideal choice for consumers looking to reduce their energy bills without sacrificing comfort.

Equipped with advanced inverter technology, the DY 036 adjusts its cooling output in response to the ambient temperature. This not only enhances comfort by maintaining a consistent indoor climate but also contributes to lower energy use. The inverter system allows the unit to operate at a variable speed, preventing the frequent on-and-off cycling associated with traditional models, which can be a significant energy drain.

Another compelling characteristic of the York DY 036 is its quiet operation. With sound levels kept to a minimum, this model is perfect for installation in environments where noise disturbances are a concern, such as bedrooms or office settings. The use of innovative sound-dampening technology ensures that the system runs unobtrusively, providing comfort without disruptive noise.

The DY 036 also incorporates an advanced filtration system that improves indoor air quality. Its multi-stage filtration process captures dust, allergens, and other pollutants, ensuring a healthier breathing environment for occupants. Regular maintenance is also streamlined with easy-access panels, allowing homeowners and technicians to perform servicing without hassle.

Durability is another hallmark of the York DY 036. Built with high-quality materials and components, it is designed to withstand varying climate conditions, ensuring long-lasting reliability. The unit also boasts advanced corrosion resistance, making it suitable for environments with high humidity or proximity to saltwater.

In summary, the York DY 036 is a cutting-edge air conditioning model that provides energy efficiency, quiet operation, advanced filtration, and durable construction. Whether for residential or commercial use, it represents a blend of comfort, technology, and reliability that meets the demands of modern climate control.