York R-407C manual Introduction

Page 6

Introduction

the optional convenience outlet. All incoming power is connected in one location, reducing the cost of field-supplied and installed power wiring.

Factory-mounted and wired controls – All con- trol points within the unit are factory-installed, wired and tested. The OptiLogicTM controls can commu- nicate with BACNet IP.

Non-fused disconnect – A factory-installed non- fused disconnect switch simplifies unit installation and serviceability by reducing installed labor costs. The disconnect switch is interlocked with the power cabinet ensuring that all power to the unit has been disconnected before servicing.

Design Flexibility

Low Ambient Operation – Head-pressure control is accomplished via a VFD motor controller rather than an inefficient and noisy condenser fan damper. By varying the speed of the condenser fan, better control and quieter operation is obtained during the colder months. Low ambient controls are available

on all systems offering higher rooftop cooling ca- pacity than competitive units.

Hot Gas Bypass – Optional on constant volume units, hot gas bypass reduces the cycling of compressors which helps prolong the life of the equipment.

Supply Air Openings – Side supply connections are available on select configurations, offering more flexibility for duct layout and improving sound trans- mission characteristics.

Compressor Sound Blankets – For applications in sound-sensitive areas, compressor sound blan- kets are available to reduce sound emitted from the rooftop unit.

Fan Spring Isolators – One-inch spring isolation is used to prevent vibration transmission from the rooftop unit’s supply fan to the building. Two-inch spring isolation is also available.

Harsh Environments – A variety of coil coating and materials are available as well as hail guards to pro- tect coils from weather damage. Seismic and hurri- cane duty curbs and fan restraints are available.

6

YORK INTERNATIONAL

Image 6
Contents Packaged Rooftop Air Conditioning Units 407C Optimized Through 65 TonsTable of Contents Nomenclature Basic Model NumberFEATURES/BENEFITS IntroductionEcological and Economical Design Serviceability Install with Ease and SafetyReliable Scroll Compressor Technology Introduction Physical Data Physical DataPhysical Data Cont’d Rigging Application DataLocation EconomizerHarsh Environments Condenser and Evaporator Coil Protection Building Exhaust SystemsRoof Curb Given Selection ProcedureAcoustical Considerations Select UnitCooling Performance Data 50 Ton Model Cooling Performance Data 50 TON ModelCooling Performance Data 50 TON Model CONT’D Cooling Performance Data 55 Ton Model Cooling Performance Data 55 TON ModelCooling Performance Data 55 TON Model CONT’D Cooling Performance Data 60 Ton Model Cooling Performance Data 60 TON ModelCooling Performance Data 60 TON Model CONT’D Cooling Performance Data 65 Ton Model Cooling Performance Data 65 TON ModelCooling Performance Data 65 TON Model CONT’D Fan Performance 50 Through 65 TON Supply FAN Data50 Through 65 TON Supply FAN Data CONT’D 50 Through 65 TON Exhaust FAN Data Component Static Pressure Drops Inches of Water Column Filters Economizer Economizer Dampers Rigid Filter Manual or Load Definitions Electrical Service SizingElectrical Data CompressorsPremium Efficiency Supply and Exhaust FAN Motor ODP or TefcHigh Efficiency Condenser FAN Motors / EachControl Sequences for ALL Units Unoccupied / Occupied SwitchingControls GeneralVentilation Control Sequences Exhaust Control SequencesLOW Ambient Operation Smoke Purge SequencesVAV Specific Sequences Cooling OperationCooling Operation Thermostat Control Stand Alone ControlCV Specific Sequences Stage 1 Y1 CallPower Wiring SINGLE-POINT Power Supply WiringSINGLE-POINT Power Supply Wiring With NON-FUSED Disconnect SINGLE-POINT Power Supply Wiring with NON-FUSED DisconnectDUAL-POINT Power Supply Wiring DUAL-POINT Power Supply WiringField Control Wiring Field Control WiringGeneral Arrangement DrawingBottom Supply Bottom Return Left or Right Rear Return Supply General Arrangement DrawingCurb Layout Drawing Curb Layout DrawingSupply AIR System Guide SpecificationsConstruction Bearings and DrivesAIR Inlet System Power SupplyAIR Filtering System Refrigeration SystemAccessories and Options ControlsEconomizers Condenser Coil Protection Relief SystemEvaporator Coil Protection Suction and Discharge Pressure Transducers moniYork International York International Proud Sponsor Olympic Team