Table 21 AddVolumeSetting2 Tag Parameters
Layer | Column in | Parameter | Setting | Range of | Number of |
| Spreadsheet |
|
| Values | Characters |
|
|
|
| ||
First layer |
|
| Information about external volumes and the primary path | ||
| A | PathGroup | Path group | 0 to 63231 | 5 decimal digits or |
|
|
| number |
| fewer |
| B | Port | Port number of | 1A to GR | 2 digits or fewer |
|
|
| the primary path |
|
|
| C | WWN | WWN of the | 00000000 | 16 hexadecimal |
|
|
| primary path | 00000000 to | digits |
|
|
|
| FFFFFFFF FFFFFFFF |
|
| D | LUN | LU number set to | 0000 to 0FFF | 4 hexadecimal |
|
|
| the external |
| digits or fewer |
|
|
| volume |
|
|
| E | ExG | External volume | Grp: 1 to 16384 | Grp: 5 decimal |
|
|
| group number | VPG: 1 to 4096 | digits or fewer |
|
|
| and its sequential | VPG: 4 decimal |
number. The | digits or fewer | |
format should be | ||
| ||
|
| |
example, |
| |
|
F | Attribute | • | Normal: |
|
|
| Maps an |
|
|
| external |
|
|
| volume |
|
| • | |
|
|
| a command |
|
|
| device |
G | CLPR | CLPR that is used | |
|
| to access the | |
|
| external volume |
•Normal
•
0 to 31
N/A
2 decimal digits or fewer
Second layer |
| Information about alternate paths. Specify the paths in the | ||
|
| order of descending priorities. |
| |
A | + | Identifier | N/A | N/A |
B | Port | Port number of | 1A to GR | 2 digits or fewer |
|
| the alternate path |
|
|
C | WWN | WWN of the | 00000000 | 16 hexadecimal |
|
| alternate path | 00000000 to | digits |
|
|
| FFFFFFFF FFFFFFFF |
|
Third layer |
| Information about LDEVs to be created in an external | ||
|
| volume |
|
|
112 Using Spreadsheets for XP External Storage Operations