York D2EB Power And Control Wiring, Compressors, Typical Field Wiring Diagram, Power Wiring

Page 4
POWER AND CONTROL WIRING

POWER AND CONTROL WIRING

Field wiring to the unit must conform to provisions of the current N.E.C. ANSI/NFPA No. 70 or C.E.C. and/or local ordinances. The unit must be electrically grounded in accordance with local codes or, in their absence, with the N.E.C./C.E.C. Voltage toler- ances which must be maintained at the compressor terminals during starting and running conditions are indicated on the unit Rating Plate and Table 3.

174065-YIM-A-0206

Electrical line must be sized properly to carry the load. Each unit must be wired with a separate branch circuit fed directly from the meter panel and properly fused.

Refer to Figure 2 for typical field wiring and to the appropriate unit wiring diagram for control circuit and power wiring information.

The wiring entering the cabinet must be provided with me- chanical strain relief.

A fused or HACR breaker disconnect switch should be field pro- vided for the unit. If any of the wire supplied with the unit must be replaced, replacement wire must be of the type shown on the wir- ing diagram.

COMPRESSORS

Units are shipped with compressor mountings factory-adjusted for shipping. CAUTION: Loosen compressor mounting bolts half turn before operating unit.

 

 

CONTROL WIRING

THERMOSTAT

UNIT TERMINAL STRIP

** = Minimum wire size of 18 AWG

4

**

4

 

 

 

wire should be used for all field

 

 

 

installed 24 volt wire.

/

 

/

 

 

 

NOTE:

HEAT ANTICIPATOR SHOULD BE SET AT 0.25 AMPS FOR ALL MODELS.

PROGRAMMABLE

THERMOSTAT ONLY

*= Only required on units with supplemental electric heat.

;;

9 * 9

++

24 VOLT TRANSFORMER

CAUTION: Label all wires prior to disconnection when servicing controls. Wiring errors can cause improper and dangerous operation. Verify proper operation after servicing.

POWER WIRING

REFER TO ELECTRICAL DATA

TABLES TO SIZE THE DISCON-

NECT SWITCH, WIRING &

OVERCURRENT PROTECTION.

FIG. 2 - TYPICAL FIELD WIRING DIAGRAM

4

Unitary Products Group

Image 4
Contents INSTALLATION INSTRUCTION REPLACEMENT PARTSGENERAL REFERENCEINSTALLATION LIMITATIONSTABLE 1 - UNIT APPLICATION DATA LOCATIONSERVICE ACCESS CLEARANCESDUCT WORK FILTERSPOWER AND CONTROL WIRING FIG. 2 - TYPICAL FIELD WIRING DIAGRAMCONTROL WIRING POWER WIRINGTABLE 4 - ELECTRICAL DATA BASIC UNIT TABLE 5 - ELECTRICAL DATA COOLING / ELECTRIC HEAT Checking Supply Air CFM DEB Coil Delta P vs Airflow174065-YIM-A-0206 174065-YIM-A-0206 FIG. 3 - DIMENSIONS AND CLEARANCES FRONTFRONT 14 BACKCooling SEQUENCE OF OPERATIONHeating MAINTENANCE NORMAL MAINTENANCEDETAIL A SEE DETAIL BTYPICAL WIRING DIAGRAM LEGEND TYPICAL WIRING DIAGRAM NOTES174065-YIM-A-0206 Unitary Products Group174065-YIM-A-0206 Unitary Products GroupUnitary Products Group 5005 York Drive, Norman OklahomaSupersedes Nothing 174065-YIM-A-0206