HP A0554832 manual 2000

Page 31

Figure 7: Typical Portable Chiller Microprocessor Controllers

PV

S V

OUT1

OUT2 MANU STOP RMT AT

SUB1

AT

OMRON

E5CK

HT

CL

AL

REM

 

 

 

 

°F

T

 

 

 

°C

 

 

 

 

%

SP

 

2000

 

MADE IN U.S.A.

 

2-40 HP Portable Chillers

Chapter 4: Operation

31 of 78

Image 31
Contents Hp Portable Chillers Shipping Information Table of Contents Operation HP Portable Chillers How to Use This Manual SafetySafety Symbols Used in this Manual Responsibility Wear Safety Glasses and Work GlovesModels Covered in This Manual Functional DescriptionChilled Water Circuit General DescriptionRefrigeration Circuit Mechanical Features Standard FeaturesOther Mechanical Features Other Features Electrical FeaturesRefrigeration Features Controller FeaturesHigh Pressure Cutout Safety Devices and InterlocksHigh/Low Thermostat Control Crankcase HeaterFlow Switch Oil Pressure Safety SwitchFan Cycling Switch Pressure SwitchOptional Features Mounting Features Optional Pump Amperages Voltage Construction Full Load Amps Uncrating InstallationElectrical Connections Water Treatment Considerations Process Water ConnectionsBypass Valve Considerations Galvanic Corrosion ConsiderationsWater-Cooled Chiller Condensers Condenser ConsiderationsAir-Cooled Chiller Condensers Remote Air-Cooled Chiller Condensers Page Equivalent Length in Feet for Valves and Fittings Refrigerant Charge Determination Chiller Condenser Charge Field Installed Piping ChargeCondenser Fan Three-Phase CompressorsChecking Motor Direction Water PumpsPart Number Description Water ReservoirEthylene Glycol and Propylene Glycol Curves Automatic Water Make-Up Option Initial Start-Up Microprocessor Controllers Panel Buttons, Indicator Lights, and SwitchesE5CK Controller Indicator Name Description OperationSterlco 2000 Controller Indicator Name Description Indicator Name Description2000 Graphic Panel See on Indicator Name DescriptionIndicator Name Description With Sterlco 2000 Controller Typical Graphic Panels With E5CK ControllerOptional Communications Setting the Process Water TemperaturesAuto-Tuning Start-upProgramming the Electronic High/Low Thermostat Thermostat Buttons Indicator Name DescriptionSelect Fahrenheit or Celsius Stage 2 High Temperature ProtectionStage 1 Freeze Protection Filter Cleaning MaintenanceLubrication Air- and Remote Air-Cooled Chillers Maintaining the CondenserMaintaining the Evaporator Evaporator Process Piping Y-StrainerPreventative Maintenance Service HP Portable Chillers Troubleshooting TroubleshootingHP Portable Chillers Troubleshooting Appendix WarrantySales Department Service DepartmentTechnical Assistance Parts DepartmentHp and 3 1/2 hp Air-Cooled Portable Chillers Drawings and SpecificationsHp and 7.5 hp Air-Cooled Portable Chillers Hp and 15 hp Air-Cooled Portable Chillers 20 hp, 25 hp, and 30 hp Air-Cooled Portable Chillers Nominal Condenser water Nominal cooling Water Com Hp and 3.5 hp Water-Cooled Portable ChillersIn. NPT Height Width Depth Lbs Hp and 7.5 hp Water-Cooled Portable Chillers Hp and 15 hp Water-Cooled Portable Chillers 20 hp, 25 hp, and 30 hp Water-Cooled Portable Chillers Hp and 40 hp Water-Cooled Portable Chillers 748 Nominal cooling Com Refrigeration Power in amps eHp and 7.5 hp Remote Air-Cooled Portable Chillers 12.8 17.315.0 40.9 34.0 74.7 Hp and 15 hp Remote Air-Cooled Portable ChillersNominal cooling Com Refrigeration Pres Nom ConnectionsTo/from No tank Tank, to/from Height Width Depth Lbs Hp through 40 hp Remote Air-Cooled Portable Chillers‘A’in ‘B’in ‘C’in ‘D’in ODSin Remote Condenser Assembly ModelsHertz Pump Curves Pump Curves, Flow, and Pressure ConsiderationsDWG. No. S0554823 Calculating Chiller Nominal Flow and Pressure to Process Water Pressure Drop TablesRecirc. power Flow Rate ∆ pressure Gpm Lpm Psi KPa Recirculation Pump SpecificationsFlow and Pressure Considerations Configuration a Remote Air-Cooled Chiller ConfigurationsConfiguration B Configuration C Typical Ductwork for Air-Cooled Chillers Central and Gravity Return Piping with Standpipe Diagram Piping DiagramsTypical Piping Schematic, 2 and 3 1/2 hp Models HP Portable Chillers Appendix HP Portable Chillers Appendix Typical Piping Schematic, 5 hp through 40 hp, No-Pump Models HP Portable Chillers Appendix Speed Fuses Electrical SchematicsTime-delay Relays Disconnect Switch Optional Typical Electrical SubpanelTypical Electrical Schematic, 2 hp and 3 1/2 hp Models A0554815 Typical Power Wiring Schematic, 5 hp through 40 hp ModelsHP Portable Chillers Appendix DWG A0554931 DWG A0562343 DWG A0562435 Typical Wiring Schematic, 35 hp and 40 hp Models with Pump DWG A0562434