United States Stove 6035 owner manual Corn & Pellet Multifuel Stove, Save These Instructions

Page 1
K e e p i n g

K e e p i n g

North America Warm

Since 1869

CORN & PELLET MULTIFUEL STOVE

6035

OWNER’S MANUAL

Installation - Operation - Maintenance Instructions - Repair Parts

READ THIS ENTIRE MANUAL, THOROUGHLY, BEFORE ATTEMPTING TO INSTALL AND/OR BURN YOUR NEW AMERICAN HARVEST CORN AND PELLET MULTI-FUEL STOVE. FAILURE TO FOLLOW THESE INSTRUCTIONS MAY RESULT IN PROPERTY DAMAGE, BODILY INJURIES OR EVEN DEATH.

Safety Notice: If this stove is not properly installed, a house fire may result. For your safety, follow the installation directions. Contact local building or fire officials about restrictions and installation requirements peculiar to your area. Do Not Plug this appliance into an electrical outlet before reading and understanding all operations and always unplug the unit before attempting any work or maintenance. Do not connect this stove to any chimney flue already serving another appliance. Carefully observe and maintain all clearances and combustibles.

A note about fuel: Use only dried shelled corn with a moisture content of 14% or less (11 to 12% provides the best results); any pellet fuel used should have an ash content of 1% or less. If not efficiency will suffer, and your warranty may be voided.

Your American Harvest Corn/Pellet Stove operates on a negative pressure. Therefore, all venting connections (elbows, T-pipe) must be sealed and airtight.

Use Hi-Temp silicone at each joint or connection.

SAVE THESE INSTRUCTIONS

UNITED STATES STOVE COMPANY GRANTS NO WARRANTY, IMPLIED OR STATED, FOR THE INSTALLATION OR MAINTENANCE OF THE STOVE AND ASSUMES NO RESPONSIBILITY FOR ANY CONSEQUENTIAL DAMAGE(S).

UNITED STATES STOVE COMPANY - 227 INDUSTRIAL PARK ROAD-SOUTH PITTSBURG, TN. 37380

TECHNICAL ASSISTANCE (423) 837-2100 - (423) 837-2109 FAX

USSC

851576A

Image 1
Contents 6035 CORN & PELLET MULTIFUEL STOVEK e e p i n g North America Warm Since SAVE THESE INSTRUCTIONSNOTE YOUR UNIT MUST BE INSTALLED BY A SPECIFICATIONSQUALIFIED HEATER INSTALLER CONGRATULATIONSBURNING SOLID FUELS SAFETY STEPSUSSC WOOD PELLETS BURNING SOLID FUELS continuedCLEARANCES TO COMBUSTIBLES INSTALLATION REQUIREMENTSFLOOR PROTECTION Parallel / Alcove InstallationGUIDELINES FOR EXHAUST VENTING SYSTEMS DESIGN CLEARANCES TO COMBUSTIBLES continuedHEARTH PROTECTION USSC WIND HOOD TERMINATION 90 DEGREE BEND TERMINATIONWind Hood 3” Min. Diameter MOBILE HOME INSTALLATION REQUIREMENTS INSTALLATION CONFIGURATIONSDO NOT INSTALL IN SLEEPING ROOM ROOF MUST BE MAINTAINEDALCOVE-THROUGHTHE WALL INSTALLATION REQUIREMENTS ALCOVE INSTALLATION REQUIREMENTSCorner Installation ALCOVE CLEARANCE RECOMMENDATIONSHorizontal Exhaust Termination FREESTANDING STOVE INSTALLATION REQUIREMENTSINSIDE VERTICAL PIPE WITH ROOF TERMINATION THROUGH THE ROOF CLEANING THE GLASS GLASS MAINTENANCE, REMOVAL AND REPLACEMENTREMOVAL OF BROKEN OR DAMAGED CERAMIC GLASS Do not use abrasive cleanersAdjustable Door Handle STOVE CONTROLSService Note Front View Circuit Board Control PanelDamper Control Function LIGHTING INSTRUCTIONSCIRCUIT BOARD FUNCTIONS DISPOSAL OF ASHESStart-up ShutdownMAINTENANCE INSTRUCTIONS SETTING THE DRAFTDaily Maintenance Soot and Flyash - Formation and Need for RemovalWeekly Maintenance Maintenance Instructions ContinuedSPRING CLEANING SPECIALCLEANING/OPERATIONALINSTRUCTIONSHOPPER AUGER SAFETY SWITCH LOCATION AUTOMATIC SAFETY FEATURESMicro Switch Pressure SwitchFUEL ADDITIVE THERMOSTAT INSTALLATIONBack of Circuit Board PROBLEM TROUBLE SHOOTINGSOLUTIONS CAUSESPROBLEM TROUBLE SHOOTING continuedSOLUTIONS CAUSESPROBLEM TROUBLE SHOOTING continuedSOLUTIONS CAUSESUSSC WIRING DIAGRAMUSSC REPAIR PARTS DIAGRAM-6035PART # REPAIR PARTS LIST-6035DESCRIPTION HOW TO ORDER REPAIR PARTS