United States Stove 6035 owner manual BURNING SOLID FUELS continued, Wood Pellets

Page 4
BURNING SOLID FUELS continued...

BURNING SOLID FUELS continued...

SHELLED CORN (Dry, preferably corn with 11- 12% moisture content)

Corn must contain less than 14% moisture content. Wet corn will rapidly deteriorate stove components, reduce efficiency and void all warranties. Purchase a moisture tester if in doubt.

Corn must be clean and free from debris. Never burn corn right from the field. Damage caused by dirty corn is not covered by the product warranty. Ask for clean filtered bagged corn only. Stalk parts, excessive fines and cob remmants will clog the auger.

NEVER BURN SEED CORN IN YOUR STOVE. Seed corn is treated with chemical pesticides that are harmful or fatal if swallowed, therefore, seed corn is dangerous to have in the house, especially where children can reach it.

Never burn “Deer Corn.” It frequently contains molasses/sugars.

Store your corn supply in a dry place and keep bags or container sealed to prevent your corn from absorbing excess moisture. Test the moisture content periodically to maintain the proper dryness.

There are many varieties of corn grown around the world. Each variety has unique characteristics including the shape and size of the kernel. Your stove will burn more consistently with a small to midsize kernel corn. If the kernel size of the corn varies greatly or if you switch sources frequently, you will get a less consistent burn, which will require more attention to the draft setting on your stove. Therefore, purchasing corn from the same source will help achieve a more consistent burn. DO NOT USE CORN WITH A HIGH WAX CONTENT!

WOOD PELLETS

As with corn, be consistent in your pellet supplier. Pellets will vary in content and burn characteristics from supplier to supplier. A consistent supply of pellets will require fewer adjustments to the draft of the stove.

Check your pellets for foreign objects. Your stove warranty will not cover damage done to your stove due to foreign objects in the fuel supply.

Store your pellets in a dry place to prevent them from absorbing excess moisture.

To decrease sawdust buildup, the hopper will need to be vacuumed out after every 6-8 bags of pellets or more often if the pellets are poor quality. You may have to screen each bag of pellets if sawdust becomes a problem.

Wood Pellets vary in size and ash content from less than 1% to 3% or more. Your stove will burn more efficiently with small to midsize pellets. Low ash content pellets will allow you to burn the stove longer between cleanings. Only wood pellets manufactured to the Association of Pellet Fuel Industries (A.P.F.I.) standard for residential pellets fuels are recommended. Performance will suffer if nonstandard pellets are used. Consult your local American Harvest reseller for more information on approved wood pellet fuel.

CAUTION: DO NOT PLACE SUCH FUELS WITHIN THE SPACE HEATER’S INSTALLA- TION CLEARANCES OR WITHIN THE SPACE REQUIRED FOR CHARGING AND ASH REMOVAL.

4

USSC

Image 4
Contents CORN & PELLET MULTIFUEL STOVE 6035K e e p i n g North America Warm Since SAVE THESE INSTRUCTIONSSPECIFICATIONS NOTE YOUR UNIT MUST BE INSTALLED BY AQUALIFIED HEATER INSTALLER CONGRATULATIONSBURNING SOLID FUELS SAFETY STEPSUSSC BURNING SOLID FUELS continued WOOD PELLETSINSTALLATION REQUIREMENTS CLEARANCES TO COMBUSTIBLESFLOOR PROTECTION Parallel / Alcove InstallationGUIDELINES FOR EXHAUST VENTING SYSTEMS DESIGN CLEARANCES TO COMBUSTIBLES continuedHEARTH PROTECTION USSC WIND HOOD TERMINATION 90 DEGREE BEND TERMINATIONWind Hood 3” Min. Diameter INSTALLATION CONFIGURATIONS MOBILE HOME INSTALLATION REQUIREMENTSDO NOT INSTALL IN SLEEPING ROOM ROOF MUST BE MAINTAINEDALCOVE INSTALLATION REQUIREMENTS ALCOVE-THROUGHTHE WALL INSTALLATION REQUIREMENTSCorner Installation ALCOVE CLEARANCE RECOMMENDATIONSFREESTANDING STOVE INSTALLATION REQUIREMENTS Horizontal Exhaust TerminationINSIDE VERTICAL PIPE WITH ROOF TERMINATION THROUGH THE ROOF GLASS MAINTENANCE, REMOVAL AND REPLACEMENT CLEANING THE GLASSREMOVAL OF BROKEN OR DAMAGED CERAMIC GLASS Do not use abrasive cleanersSTOVE CONTROLS Adjustable Door HandleService Note Front View Circuit Board Control PanelLIGHTING INSTRUCTIONS Damper Control FunctionDISPOSAL OF ASHES CIRCUIT BOARD FUNCTIONSStart-up ShutdownSETTING THE DRAFT MAINTENANCE INSTRUCTIONSDaily Maintenance Soot and Flyash - Formation and Need for RemovalMaintenance Instructions Continued Weekly MaintenanceSPRING CLEANING SPECIALCLEANING/OPERATIONALINSTRUCTIONSAUTOMATIC SAFETY FEATURES HOPPER AUGER SAFETY SWITCH LOCATIONMicro Switch Pressure SwitchFUEL ADDITIVE THERMOSTAT INSTALLATIONBack of Circuit Board TROUBLE SHOOTING PROBLEMSOLUTIONS CAUSESTROUBLE SHOOTING continued PROBLEMSOLUTIONS CAUSESTROUBLE SHOOTING continued PROBLEMSOLUTIONS CAUSESWIRING DIAGRAM USSCREPAIR PARTS DIAGRAM-6035 USSCPART # REPAIR PARTS LIST-6035DESCRIPTION HOW TO ORDER REPAIR PARTS