![? Blower will not operate.](/images/new-backgrounds/35265/3526547x1.webp)
TROUBLE SHOOTING continued...
PROBLEM |
| CAUSES |
| SOLUTIONS |
|
|
|
|
|
? Blower will not operate. | • | No power to stove | • | Check to see that the stove is |
|
|
|
| plugged into the wall outlet. |
| • | No power to control board | • | Check to see if your circuit breaker |
|
|
|
| has “tripped”. |
|
|
| • Check wire connection between the | |
|
|
|
| high limit snap switch and the termi- |
|
|
|
| nal block. |
|
|
|
|
|
? Soot or fly ash in the house. | • | Cleaning the window, particularly | • | Clean the glass when the unit is not |
|
| when the stove is operating. |
| running. |
| • | Leakage on the joints between the | • | Seal any leaks in the exhaust sys- |
|
| combustion fan, exhaust pipe and |
| tem with RTV high temperature sili- |
|
| “PL” vent. This will be evidenced by |
| cone sealer. |
|
| dust on the impeller of the convec- |
|
|
|
| tion fan and in the heat exchanger |
|
|
|
| tubes. |
|
|
|
|
|
|
|
? Buildup of soot on glass, venting and | • | Dirty fuel. | • | Make sure you have clean fuel. |
heat exchangers. | • | Wet Corn (above 15% moisture). | • | Dry corn down to |
| ||||
| • | Inadequate air supply. |
| if possible or mix with wood pellets. |
| • Pull manual draft control out slightly | |||
|
|
| ||
| • Negative pressure in home. |
| to make sure that there is appox. ½ | |
| • | Lack of maintenace |
| inch of fuel in firepot. |
| • | Install outside air to unit and make | ||
|
|
| ||
|
|
|
| sure that the home has adequate |
|
|
|
| makeup air. (suggested 6” makeup |
|
|
|
| air into basement) |
|
|
| • | Preform maintenace |
|
|
|
|
|
CAUTION: When performing any internal electrical maintenance
•Moving parts inside of the cabinet may cause injury. Do not operate unit with panels removed or open.
•HOT parts. Do not operate the unit with panel open.
•Risk of electric shock. Disconnect power before servicing unit.
•In the event of component failure, replace with the original factory equipment.
24 | USSC |