Lochinvar RSB-i&s-05, CP-5M-4/08, 45, 000 - 500, 000 Btu/hr warranty Contents User Warning

Page 2

CONTENTS

 

USER WARNING

 

 

 

Warranty

1

Safety Warnings

1

Codes

3

Location

3

Clearances

4

Combustion/Ventilation Air Requirements

4

Conventional Venting

7

Masonry Chimney Installations

10

Sidewall Venting

10

Automatic Vent Damper

11

Gas Supply

12

Gas Pressures & Piping

12

Manifold Pressure Adjustment

15

Supply Pressure Measurement

16

Gas Valves

17

Relief Valve

18

Flow Switch

18

Electrical Connections

19

Temperature Adjustment

20

Temperature Limit Control

22

Blocked Vent and Flame Roll-Out System

23

Lighting Instructions

24

Ignition & Control Timings

28

Freeze Protection

28

Maintenance

29

Flame Patterns

29

Inspection Cleaning Procedure

30

Heat Exchanger/Burner Access

30

Inspection and Cleaning

30

Gas Train

32

Heating Boiler

32

Installation Requirements

32

Pump Requirements

32

Pressure Drop Chart

33

Boiler Pump Operation

33

Typical Piping

33

Bypass Requirements

33

Low Temperature Systems

35

Boiler Flow Rates

35

Placing Boiler in Operation

36

Temperature Rise Chart

37

Boiler Temperature Control

38

Remote Thermostat Control Connection

38

Power Venter Connection

38

Domestic Water Heater

38

Water Velocity Control

39

Temperature Rise

39

Water Chemistry

40

Pump Operation

40

Risk of Scald Warnings

42

Troubleshooting

44

Wiring Diagrams

46

Revision Notes

Back Cover

The information contained in this manual is intended for use by qualified professional installers, service technicians or gas suppliers. Consult your local expert for proper installation or service procedures.

IMPORTANT

Consult and follow local Building and Fire Regulations and other Safety Codes that apply to this installation. Consult your local gas utility company to authorize and inspect all gas and flue connections.

IMPORTANT

Your conventionally vented gas appliance must have a supply of fresh air circulating around it during burner operation for proper gas combustion and proper venting.

￿WARNING

Should overheating occur or the gas supply fail to shut off, do not turn off or disconnect the electrical supply to the pump. Instead, shut off the gas supply at a location external to the appliance.

￿WARNING

To minimize the possibility of serious personal injury, fire or damage to your unit, never violate the following safety rules.

1.Boilers and water heaters are heat producing appliances. To avoid damage or injury, do not store materials against the appliance or the vent- air intake system. Use proper care to avoid unnecessary contact (especially children) with the appliance and vent-air intake components.

2.Never cover your appliance, lean anything against it, store trash or debris near it, stand on it or in any way block the flow of fresh air to your appliance.

3.UNDER NO CIRCUMSTANCES must flammable materials such as gasoline or paint thinner be used or stored in the vicinity of this appliance, vent-air intake system or any location from which fumes could reach the appliance or vent-air intake system.

2

Image 2
Contents Checking Equipment WarrantySpecial Instructions to Owner Contents User Warning Location of Unit Installation ProcedureCodes Clearance from Combustible Construction Clearances from Combustible ConstructionCombustion Air Through Ducts Table a Minimum Recommended Combustion AIR Supply OpeningsTable B Vent Pipe Sizes VentingConventional Negative Draft Venting System Input Btu/hr Flue SizePage Venting Termination Vent Termination from Peaked Roof 10’ or Less from RidgeSidewall Venting Masonry Chimney Installation Inspection of a Masonry ChimneyAutomatic Vent Damper Vent Damper and Vent Damper Terminal BlockGAS Connection GAS Supply GAS Pressure TestTable C Table D Manifold PressureBtu/hr Distance from Meter In Feet Table F Fittings to Equivalent Straight PipeTable G GAS Connections Install Piping to Control GAS PipingGAS Manifold Pressure Adjustment Procedure WrenchChecking GAS Supply Pressure PilotCombination GAS Valves Venting of Combination Gas ValvesRelief Valve Water Flow Switch if Equipped Relief Valve Water HeaterTWO Stage Burner Control System Minimum Flow Rate Required to Actuate Flow SwitchLOW Water Cutoff if Equipped Table J AMP Draw DataOperating Temperature Control Temperature AdjustmentTemperature Control Settings Locating Temperature ControlWiring of Remote Sensors Temperature Control SensorsInstallation of Remote Sensors High-Fire OffsetOutdoor AIR Reset Option Additional Temperature ControlsInitial START-UP Blocked Vent and Flame ROLL-OUT/FLAME Interlock SwitchManual Reset High Water Temperature Limit Lighting Instructions for Standing Pilot Models F1 PRE-START ChecklistInput for Your Safety Read Before Operating What to do if YOU Smell GASLighting Wand Lighting Instructions for Spark Ignition Pilot Models F9/M9 Safety Shutoff Test for Standing Pilot Ignition SystemTo Turn OFF GAS to Appliance Safety Shutoff Test for Spark Ignition Pilot System Operating Instructions To Turn OFF GAS to ApplianceFreeze Protection for a Heating Intermittent Pilot Spark Ignition System F9/M9Freeze Protection F9/M9 Intermittent Spark Ignition Pilot ModelsMaintenance Water TreatmentInspection Cleaning Procedure Removal of Combustion Chamber Lining or Base PanelsOuter Air Deflector and HEX Filler Bracket Piping of the Boiler System GAS Train and ControlsWater Connections Heating Boilers only Circulator Pump RequirementsCirculator Pump Operation Circulator Pump SpecificationsTable L PRIMARY/SECONDARY Boiler Piping Primary/Secondary Piping of a Single BoilerBoiler Flow Rates LOW Temperature Bypass RequirementsThree WAY Valves Table M Minimum Required Flow for Heating Boiler General Plumbing RulesInstallation with a Chilled Water System Table NTable O Terminal Strip Wiring Boiler Operating Temperature ControlPower Venter Connection To Terminal Strip Wire GaugeWater Velocity Control Required Temperature RiseTable P Required Temperature Rise Btu/hr To 7 Grains To 25 Grains HardnessPump Operation Water ChemistrySoftened Water Systems Minimum Pump Performance Remote Sensor Installation InstructionsThermostat Settings Heat ExchangerAutomatic Vent Dampers Optional Relief ValveDo not plug or cap the relief valve discharge Thermal ExpansionCathodic Protection Troubleshooting Guide 90,000 270,000 Btu/hr Models Water Heaters F1 Schematic Diagram F1 Unit Schematic Diagram F9 Unit Schematic Diagram M9 Unit Schematic Diagram F9/M9 Unit Page
Related manuals
Manual 52 pages 63.01 Kb

000 Btu/hr, 000 - 500, RSB-i&s-05, 45, CP-5M-4/08 specifications

The Lochinvar 000 BTU/hr, 45,000 - 260 is a high-efficiency water heater designed for residential and commercial applications, showcasing advanced technologies that set it apart in the industry. With a powerful heating capacity of up to 260,000 BTU/hr, this unit is engineered to meet the varying demands of hot water for both large households and businesses.

One of the standout features of the Lochinvar 000 is its innovative design that maximizes energy efficiency. Utilizing condensing technology, this water heater captures and reuses exhaust gases that would otherwise be lost, thereby improving thermal efficiency significantly. The result is an impressive Energy Factor (EF) rating that not only promotes sustainability but also translates into lower energy bills for the end user.

The unit is equipped with a user-friendly digital control interface that simplifies operation and monitoring. This control system allows for precise temperature adjustments, ensuring that users can maintain their desired water temperatures effortlessly. Additionally, the advanced diagnostics provided by the control system help in troubleshooting potential issues before they develop into more significant problems, enhancing the reliability of the unit.

Durability is another hallmark of the Lochinvar 000. Constructed with high-quality materials, including a robust stainless-steel tank, this water heater is designed to withstand the rigors of daily use. The stainless-steel construction also helps to resist corrosion, which is a common issue in water heaters, thereby extending the lifespan of the unit.

Furthermore, Lochinvar has integrated safety features into the design of the 000 model, including an automatic shut-off system and advanced flame safeguard controls to prevent hazardous situations. This focus on safety ensures peace of mind for users, making it an ideal choice for family homes and workplaces alike.

In terms of installation, the Lochinvar 000 is relatively straightforward, with options for both indoor and outdoor setups. The compact design allows for flexible installation, accommodating various space requirements without compromising performance.

Overall, the Lochinvar 000 BTU/hr, 45,000 - 260 combines reliability, efficiency, and advanced technology, making it a superior choice for those seeking a powerful and dependable water heating solution. This water heater not only meets but exceeds modern expectations for performance and safety, catering to a wide range of hot water needs.